Delta-Opti CS-H9F-80HX User Manual

Ip camera tester

Advertisement

Quick Links

Manufactured in China for:
DELTA-OPTI Monika Matysiak,
60-713 Poznan, 10 Graniczna St., Poland
www.shopdelta.eu
IP camera tester
User Manual
CS-H9F-80HX
(V01.00)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS-H9F-80HX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Delta-Opti CS-H9F-80HX

  • Page 1 Manufactured in China for: DELTA-OPTI Monika Matysiak, 60-713 Poznan, 10 Graniczna St., Poland www.shopdelta.eu IP camera tester User Manual CS-H9F-80HX (V01.00)...
  • Page 2 Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera tester and use properly. For using the IP camera tester safely, please first read the「Safety Information」carefully in the manual. The manual should be kept well in case of reference. Keep the S/N label for after-sale service within warranty period.
  • Page 3: Table Of Contents

    Content 1 .Safety information ..........................1 2. IP Camera Tester Introduction ......................2 2.1 General ............................2 2.2 Packing list ..........................3 2.3 Function interface ........................4 3. Operation ............................. 7 3.1 Installing the Battery ........................7 3.2 Instrument connection ........................ 8 3.2.1 IP camera connection ......................
  • Page 4 3.3.15 TVI camera test ( *Optional ) ................... 60 3.3.16 AHD camera test ( *Optional ) ................. 62 3.3.17 Network tool ....................... 63 (1)IP address scan ......................63 (2)PING Test ........................64 (3)Network test (Ethernet bandwidth test) ................ 64 (4)Port Flashing ........................ 68 (5)DHCP server ........................
  • Page 5 3.3.37 Office ........................106 3.3.38 LED Flashlight ......................106 3.3.39 Browser ........................107 3.3.40 Notepad ........................107 3.3.41 System Setting ......................108 3.3.42 File explorer ......................112 3.3.43 Theme ........................114 3. 4 Audio test ..........................116 3.5 HDMI output ......................... 116 3.6 PoE power output........................
  • Page 6: Safety Information

    1 .Safety information ◆ The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply at the places which are inapplicable for the use of electrics such as hospital, gas station etc. ◆...
  • Page 7: Ip Camera Tester Introduction

    ◆Never connect the meter with any voltage source while the function switch is in the current, resistance, capacitance, diode, continuity, otherwise it will damage the meter. ◆Never perform capacitance measurements unless the capacitor to be measured has been discharged fully. ◆Never measure any of resistance, capacitance, diode or continuity measurements on live circuits.
  • Page 8: Packing List

    2.2 Packing list 1). Tester 2). Adaptor DC12V 2A 3). Network cable tester 4). Polymer lithium ion battery (7.4V DC 7000mAh) 5). BNC cable 6). RS485 cable 7). SC,ST connector(Only for optical power meter) 8). Multi-meter test leads one pair of red and black (only for the Multi-meter models) 9).
  • Page 9: Function Interface

    2.3 Function interface Press more than 2 seconds, turn on or off the device ,short press to turn on or off the menu display Menu key,press it to call shortcut- menu Confirm key Return/Close : Return or cancel while setting parameters of the menu, close or decrease the aperture Multimeter interface (Optional) The charge indicator: it lights red while the battery is being char...
  • Page 10 The data received indicator: it lights red while the data is being received The power indicator: it lights green while the tester is powered on by the adapter Top interface Bottom interface Visible red laser source emits Interface (Optional) DC 12V 3A power output , for provisional DC power supply PSE power sourcing equipment.
  • Page 11 LED lamp EX/HD-SDI input (BNC interface) ( Optional) TDR cable test interface (Optional) RS485 Interface: RS485communication for the PTZ Power battery switch DC 12V 2A charging interface USB 5V 2A power output (used only for power, not data) Audio input Audio output and earphone interface UTP cable port: UTP cable tester port/ Cable tracer port Anti-sunlight board...
  • Page 12: Operation

    3. Operation 3.1 Installing the Battery The battery main switch at the right-bottom corner of tester bottom. “0”: Battery power off “1”: Battery power on The tester has built-in lithium ion polymer rechargeable battery, the tester’s bottom power should turn to “0”for safety during transportation (the factory default is “0”) Using the instrument, pls switch power button to “1”, press the several seconds can turn on/off...
  • Page 13: Instrument Connection

    3.2 Instrument connection 3.2.1 IP camera connection Power an IP camera with an independent power supply, then connect the IP camera to the IPC tester’s LAN port, if the link indicator of the tester’s LAN port is green and the data indicator flickers, it means the IP camera and the IPC tester are communicating.
  • Page 14: Analog Camera Connection

    3.2.2 Analog camera connection (1) ) Connect the camera's video output to the IP tester’s VIDEO IN. The image will display on the tester after pushing the PTZ icon. (2) CCTV IP Tester “VIDEO OUT” interface connect to the Video input of monitor and optical video transmitter and receiver, the image display on the tester and monitor.
  • Page 15: Hdmi In

    (1) Connect the SDI camera's video output to the IP tester’s “SDI IN” interface, the image will display on the tester. The tester only come with SDI input interface. There is no SDI output interface. (2) Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interface (Note: positive and negative connection of the cable).
  • Page 16: Osd Menu

    3.3 OSD menu Press the key 2 seconds to turn on Press the key again to turn off short press the key to enter sleep mode, press it again to test. If tester works abnormally and cannot be turned off , Press the key several seconds to turn off, the tester reset.
  • Page 17 Click the bottom left corner" ". can open Flie expoler, Setting and Theme functions. Page.12.
  • Page 18 Click SD card, install or remove SD card. Page.13.
  • Page 19: Drop-Down Menu

    3.3.2 Drop-down Menu Press and slide at right top right corner twice to open shortcut menu. The shortcut menu includes POE power output, IP settings, Wi-Fi, HDMI IN, CVBS, Video OUT, LAN, Brightness, settings etc. HDMI: Click HDMI IN to enter, in HDMI IN mode, it can converter test from analog to digital with dual test window IP &...
  • Page 20: Short Cut-Menu

    3.3.3 Short cut menu You can call shortcut menu by press tester’s “menu” key, you can self-define shortcut menu. Press the key“ ”, you can turn on it, and switch functions, then press to enter app, tap other area on the screen, to exit the menu. Short cut-menu setting, you can long press any app in the all applications list, it will auto move to shortcut menu.
  • Page 21: Screen Capture

    3.3.4 Screen capture Long press the key “enter”, can capture screen interface and save it in any time. You can go file management to view “File management - SDcard - Pictures - Screenshots”. 3.3.5 TesterPlay Mobile screen projection (Only for android version) The meter creates WIFI hotspot, connect mobile phone to the tester’s WIFI hotspot, or the tester and mobile phone connect to the same Wi-fi network.
  • Page 22 PC screen projection: Install VLC player in the PC, turn on the VLC player "Media - Open Network Streaming", and input the RTSP address of on the top instrument two-dimensional code, click "play" to view the screen real-time projection. (you also can install “VLC player” in the mobile phone, tester and mobile phone display at the same time) Page.17.
  • Page 23: Built-In Keyboard

    3.3.6 Built-in Keyboard As ONVIF/IPC TEST/CVI/AHD/HDMI Input apps, slide screen from right to left, to call the keyboard, can zoom/Tele+/Tele- image and PTZ control. Rapid video Press enter function, One key to detect all network cameras and auto play the images. Page.18.
  • Page 24 Auto log in and display camera image. Detailed operation refer to ONVIF function. After exit ONVIF app, Click Refresh to search IP address. Page.19.
  • Page 25: Ip Discovery

    IP discovery 3.3.7 Press IP discovery , tester auto-scan the whole network segment IP, as well as auto-modify the tester’s IP to the same network segment with the scanned camera's IP. Local IP: Tester’s IP address, Tester can auto-modify the tester’s IP to the same network segment with the scanned camera's IP.
  • Page 26: Rapid Onvif Test

    Rapid ONVIF test 3.3.8 Rapid ONVIF can display 4K H.265/H.264 camera image by tester mainstream, one key to activate Hikvision camera. Press enter ONVIF function, the meter auto scan all ONVIF cameras in different network segments. It lists cameras name and IP address on the Left of screen. Tester can auto login camera and display camera image.
  • Page 27 Click the button “Refresh”, tester will scan the ONVIF camera again. Click the newly displayed ONVIF camera on the “Device List”. The tester will show the IP camera’s relative information and settings. Activate HIKVISION Camera: When connected unactivated HIKVISION Camera, tester can auto recognized ,And prompt "The camera have not activated, activated it", click "OK"...
  • Page 28 When comes out “activate success” prompt, click login to display camera image. Pop-up settings menu when click the “ONVIF setting” icon in the upper left corner Across network segments scan: After open this function , enter “Setting - IP Settings - Advanced” to add other network segments IP, Rapid ONVIF function can across network segments to scan camera’s Auto Login : After open this function, tester can auto login camera and display camera image.
  • Page 29 Video transmission protocol: UTP and TCP protocol. Open password cracker: Cracks password of cameras. View manual: Open Manual. Restore Defaults: Revert “Rapid ONVIF” to default settings. Confirm: Save the modified parameters. Click “MENU” icon to open camera setting. While in the “Live video” menu, click “Video Menu” at the top right of the image to access the following tools: Snapshot, Record, Photo, Playback, PTZ and Settings.
  • Page 30 ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly.
  • Page 31 Image setting: Click “Imaging Set” to adjust image brightness, saturation, contrast, sharpness and backlight compensation mode. Profiles: Click “profiles”, can view video streaming current configuration files, as well as switch between Major stream and minor stream. Page.26.
  • Page 32 Preview pictures: Quickly preview and zoom in or out pictures, automatically and manual refresh. Identification: Click “Identification” to view information of the camera. Page.27.
  • Page 33 Time set: Click “Time set”, Select "Manual set" to set up the time of camera. Maintenance: For camera software reset or restore to factory settings. Page.28.
  • Page 34 User Set: Modify camera user name,password etc parameters. Network setting: Click “Network Set” to change the IP address. Some cameras cannot support change IP address, so there is no change after saving. Page.29.
  • Page 35 Zoom in image: Press the key to enter the zoom mode. Press it again to exit zoom mode.When the image is enlarged tap left, right,up or down on the image to move the whole image on the screen . When the image is enlarged, if not operate on touch screen, it can operate by the keyboard,press the to zoon in , press the key to zoom out , press upward and downward key to move image.
  • Page 36 Select relative function on the bottom Toolbar to operate, “Snapshot” , “Record”, “Photos”, “Video playback”, “Storage set”, “PTZ control” etc. Snapshot: Click bottom “snapshot” to screenshot the image and store it to SD card. if select manual storage, appears dialog box “Input Name”, user-defined the files name(by Chinese character, English letter or digit ) to save in SD card, if select “Auto- storage”, the tester auto stores the files after snapshot.
  • Page 37 Playback: Click the “Playback” icon to view saved videos. Double click the video you want to play. Click to return to the last menu. To rename or delete a photo, click and hold on the file until this screen appears: Video files can play in the Video player on the main menu.
  • Page 38 Set preset position: Move the camera to preset position, enter the preset number on the Bottom right corner to complete position preset. Call the preset position: Select the preset number on the left, click "Call" to call preset. PTZ Speed set: Horizontal and Vertical Speed set. RTSP: Get RTSP address of the current camera.
  • Page 39 Doc: Auto create testing reports document of camera, click "Create document”. Click Preview to view the report document. Enter the camera test information, click "Create Document" to complete the report. Page.34.
  • Page 40: Ip Camera Test

    Click “Doc” menu again, you can preview the report document. Icons description: The description of function icons on the bottom toolbar. 3.3.9 IP camera test Display image from the 4K H.265 camera by main stream Click icon to enter IP camera test Note: Currently, the IPC Test App only supports some brands’...
  • Page 41 Local IP: This is the tester’s IP address. Click “Edit” to enter “IP setting” and change the tester’s IP address settings. IP camera type: Click on the IP Camera type to select the Manufacturer and model number of the integrated IP camera. “Manual”: Click IP camera type, list Honeywell , Kodak,Tiandy, Aipu-waton, ACTi,WoshiDA IP camera etc.
  • Page 42 Stream code: When test camera via RTSP, you can select mainstream or sub stream to test (if camera’s RTSP have not been start or without, it will tip “auto match” fail, please witch to manually selecting . IP Camera's IP: Enter the IP camera’s IP address manually or click “Search” to auto-scan for the IP camera’s IP address.
  • Page 43: Hdmi In

    If IP address setting has error or IP camera is not connected.. The tester prompts “Network Error”. Click to quit from image display and return to IP camera test interface. Once you are viewing video on the IPC Test app, you will see the “Video Menu” icon on the top right.
  • Page 44 (1) Snapshot Click the icon “Snapshot”, when the video in, to take a picture and save the current video frame in the SD card as JPEG file. If the unit is set to the manual mode an “Input Name” pop up box will appear and you can enter a title for the snapshot.
  • Page 45 (2) Video record When you click the “Record” icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the “Record” icon again to stop recording and save the video file to the SD card. If select manual storage, before recording begins, appears dialog box “Input Name”, user-defined the files name(by Chinese character, English letter or digit) to store in SD card , tester will hereby store the files in SD card after recording.
  • Page 46 To rename or delete an image, click and hold on the file until this screen below appears Click to close and return to PTZ controller. Page.41.
  • Page 47 (4) Recorded video playback Click the “Playback” icon to view your recorded videos. Tap on the video file image you want to watch. To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu “Video Player". Page.42.
  • Page 48: Video Monitor Test

    3.3.11 Video monitor test Analog camera test and PTZ control, click icon to enter Display the input video image, click the top menu bar icon to enter video level meter (PEAK level, SYNC level, COLOR BURST measurement) Select relative function on the right side Toolbar to operate , functions including “Photos”, “Snapshot” , “Record”...
  • Page 49 A. Protocol Use the up and down arrow keys to move the yellow cursor to the “protocol”, set corresponding Protocol and support more than thirty PTZ protocols. Such as Pelco- D,Samsung,Yaan,LiLin,CSR600,Panasonic,Sony-EVI etc. B. Port Click and move, to “port” Select the communication port for the PTZ camera controlling (RS485) C.
  • Page 50 PTZ Control: Press the key control the PTZ direction of rotation Press the key , to switch on or turn off the aperture. Press the key , adjust the focus manually Press the key , manually adjust the zoom (2) Video and storage setting Click icon “set”...
  • Page 51 Stretch two fingers outward or inward on the touch screen to zoom the image in or out. If not use touch screen to operate, press the key to zoom out , press the key zoom in, press upward and downward key to move the image. For analog video input, as the resolution is 720*480, it is normal that the zoom in image is not clear.
  • Page 52 (5) Video record When you click the “Record” icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the “Record” icon again to stop recording and save the video file to the SD card. If select manual storage, before recording begins ,appears dialog box “Input Name”, user-defined the files name(by Chinese character, English letter or digit) to store in SD card, tester will hereby store the files in SD card after recording.
  • Page 53 To rename or delete an image, click and hold on the file until this screen below appears Click to close and return to PTZ controller. (7) Recorded video playback Click the “Playback” icon to view your recorded videos. Tap on the video file image you want to watch. Page.48.
  • Page 54 To rename or delete a video, click and hold on the file until this screen appears: Video files also can play in the main menu “Video Player". (8) Video level meter Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC levels and COLOR BURST chroma level.
  • Page 55 While in PAL format, the unit will be mV, While in NTSC format, it will be IRE. 140±15IRE Video signal level 40±5IRE NTSC Chroma level( COLOR BURST) 40±5IRE SYNC signal level 1000±200mV Video signal level 300±35mV Chroma level( COLOR BURST) 300±35mV SYNC signal level Video signal PEAK to PEAK level:...
  • Page 56: Color-Bar Generator (Tv Out)

    For NTSC format, the Chroma standard level is 40 IRE For PAL format, the Chroma standard level is 280mV If the Chroma level is too low, the color will not be as deep, and some details of the image will become lighter.
  • Page 57 BNC loop test: Tester can send and receive color bar generator through the tester’s “video out and video in” port, it is for testing transmission channels, such as video Optical, video cables etc. The tester “VIDEO OUT” port to connect optical terminal’s sending port, and “VIDEO IN” Port to optical terminal’s connect its receiving port.
  • Page 58: Sdi/Ex-Sdi Camera Test ( *Optional )

    3.3.13 SDI/EX-SDI Camera Test ( *Optional ) SDI camera test, Dome camera test and PTZ control, click icon to enter. When tester receives SDI camera image, it will display the image data. Double-taps on the screen to make the image displayed full screen. The tester supports resolution upto 8MP:3840x2160 20/30FPS, 1280x720P 25Hz 1280x720P 30Hz...
  • Page 59: Cvi Camera Test ( *Optional )

    3.3.14 CVI camera test ( *Optional ) HD CVI camera, CVI dome camera test and PTZ control, click icon to enter When HD CVI signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows 1280x720P 25FPS / 1280x720P 30FPS / 1280x720P 50FPS / 1280x720P 60FPS 1920x1080P 25FPS / 1920x1080P 30FPS/2560x1440P 25FPS/2560x1440P 30FPS/3840 x 2160...
  • Page 60 (1)PTZ control 1.1 Coaxial PTZ control Click the icon“PTZ”on the right toolbar to do the corresponding setting. “Port”: select coaxial control Enter PTZ address to perform parameters setting. Operation instructions, please refer to “3.3.1 PTZ (1) Video monitor test”. The PTZ address in the tester must be consistent with the dome camera or decoder, then the IPC tester can test .After setting the parameter, the tester can control the PTZ and lens.
  • Page 61 To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ.
  • Page 62 Call preset position Tap the preset position: Tap the preset position area, input preset position number. Tap “call position” to complete call preset position. RS485 control Operation instructions, please refer to “3.3.1 PTZ (1) PTZ control parameters setting”. (2)Coaxial camera menu setting Tap icon “UTC”, select “menu setting”...
  • Page 63 Input calling dome camera menu address code, after finishing the parameter settings, you can press the or click the icon to call the dome camera menu. Press arrow keys to set. Page.58.
  • Page 64 (3) Snapshot, record, photo viewer and video play back, please refer to “3.3.1 PTZ (1) Video monitor test”. Tap “close menu” or press the key “ ” to close camera menu. (4) Save setting Click icon “Set” on the right toolbar to enter storage setting. Support auto-storage and manual storage.
  • Page 65: Tvi Camera Test ( *Optional )

    3.3.15 TVI camera test ( *Optional ) HD TVI camera, TVI dome camera test and PTZ control, Click icon to enter When HD TVI signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows: 1280x720P 25FPS / 1280x720P30FPS / 1280x720P 50FPS / 1280x720P 60FPS 1920x1080P 25FPS / 1920x1080P 30FPS / 1920x1080P 50FPS / 1920x1080P 60FPS /2048x1536P...
  • Page 66 Coaxial camera menu settings Tap icon “UTC”, select “menu setting” to enter the dome camera menu. Input calling dome camera menu address code, after finishing the parameter settings, you can press the or click the icon to call the dome camera menu. More operation instructions (such as PTZ control, coaxial camera menu setting ,snapshot, recording and playback etc), please refer to “3.3.6 CVI camera test”.
  • Page 67: Ahd Camera Test ( *Optional )

    3.3.16 AHD camera test ( *Optional ) AHD camera, AHD dome camera test and PTZ control, Click icon to enter When AHD signal input, the tester will display the image resolution on the top bar. Double-taps on the screen to make the image displayed full screen. The tester supports resolution as follows: 1280x720P 25FPS / 1280x720P 30FPS / 1920x1080P 25FPS / 1920x1080P 30FPS/2048x1536P 18FPS/2048x1536P 25FPS/2048x1536P 30FPS /2560x1440P 15 FPS/2560x1440P 25 FPS/...
  • Page 68: Network Tool

    “PTZ” cannot control , pls go “PTZ-2” ) If to coaxial PTZ control the AHD camera, no parameters setting is needed. More operation instructions please refer to “3.3.14 CVI camera test” 3.3.17 Network tool (1)IP address scan Connect the cable to the LAN port, click icon to enter, Set your IP address search range by changing the Start and End IP addresses.
  • Page 69: 2)Ping Test

    (2)PING Test Connect a network cable to the LAN port and click the icon to open the PING tool. You can set your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet time and Timeout. Press “Start” to start pinging. If the IP camera or network device is not configured properly or not plugged in, it will say “Destination host unreachable”...
  • Page 70 When test, need a tester or a computer installed Network Test Software as the Server, the other tester sends packet test. The two testers must be in the same network segment. a).Start the server: Click “Start Server” button to use the tester as a Server. It will display its IP address at the top of the screen.
  • Page 71 to send the packets and start testing. Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester. If use computer as the server, the computer IP address is:192.168.0.39 Tester as Client, tester’s IP address is:192.168.0.238.
  • Page 72 “Start” to test network bandwidth. Or use tester as a Server, computer as test Client(select Client, input tester’s IP address to test Page.67.
  • Page 73: 4)Port Flashing

    When use tester as Server,shows results: (4)Port Flashing Connect a network cable to the meter’s “LAN port”, click the icon to open the Port Flashing app. Click “Start”. The IP tester sends a unique signal to make the connected LAN port of the switch flash.
  • Page 74: 5)Dhcp Server

    Application: The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection (5)DHCP server Click on the DHCP icon to open the DHCP server app.
  • Page 75: 6)Trace Route

    (6)Trace route It is used to determine path of the IP packet access target. Note: Trace route testing results only for reference, for accurate test route tracking, Pls use professional Ethernet tester. Click to enter trace route. Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally default is 30.
  • Page 76: Rapid Ip Discovery

    Application: Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied. 3.3.18 Rapid IP Discovery Connect the cable to tester’s LAN port.
  • Page 77: Poe Power / Dc12V 3A And Dc 5V 2A Usb Power Output

    3.3.19 PoE power / DC12V 3A and DC 5V 2A USB power output When the tester is turned on, the DC 12V and DC 5V power output functions are automatically turned on. If the IP tester is turned off, the DC 5V USB can still be used to power an external USB device. To use the PoE Power Output function, click on the icon and change the switch “ON”...
  • Page 78: Cable Test

    3.3.20 Cable Test Click icon to enter Test LAN cable or telephone cable. Connect LAN cable or telephone cable with the CCTV tester and cable tester. And then the connecting status, cable type and the sequence of wires as well as the serial number of the cable tester kit will be displayed.
  • Page 79: Rj45 Cable Tdr Test

    3.3.21 RJ45 cable TDR test Connect cable to tester’s LAN port, click icon to enter RJ45 cable TDR test app. Test once: Test cable status, length and attenuation. Repeat test: Continue to test cable status, length and attenuation. Status: After link up, screen display “online”, if not link up or open circuit, screen display “open circuit”, if cable pair is short circuit, screen display “short circuit”.
  • Page 80 Length: The max test length is 180 meters, when cable is open circuit or short circuit, can test the cable length, if screen display “online”, the testing result would be not accurate. Cable quality test: Green is good quality cable, Yellow is Poor quality cable, Red is water poured cable, the attenuation value will be displayed when cable over 10 meters.
  • Page 81 Connection diagram: Cable sequence diagram: A straight- through and cross-over cable diagram, the cable sequence display for reference. Page.76.
  • Page 82: Cable Tracer

    Click “Help”, check the instruction of all parameters. 3.3.22 Cable Tracer Connect test cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port on the bottom. Click icon to enter, click the Number on the screen to adjust audio type. Page.77.
  • Page 83: Tdr Cable Test ( *Optional )

    Use the blue Combination cable identifier and network cable tester’s copper pointer to touch all the cables in the bundle. You are searching at the other end. The cable that gives off the loudest tone is the cable connected to the tester.
  • Page 84 Built-in BNC cable, network cable, RVV control cable, Telephone line and TVVB cable etc can test, 11 groups user-defined cable can be set. Click “Cable” “Type” to select cable and start testing. One tap on “Start” do one testing. If select built in cable type for testing, click “+”...
  • Page 85 User-defined calibration: Choose the cable 100 meters to 200 meters (more than 50 meters), click “Cable”, “Type” to select user-defined 1 for calibration, 11 groups user-defined can be set. 1.Select user-defined and click “Calibration” to enter test , click “user-defined 1” can define cable name,such as: AiPu BNC-5 2.
  • Page 86 3.Click “+” or “-” to adjust wave speed ,while display length is the same with the actual Length ,click “Save” to save calibration data. It can be used for the same cable testing next time. Application: TDR test is used for pulse reflection method, to transmit pulse signal for tested cable, when cable is open circuit or short-circuit, reflected pulse is generated, the tester receives and deals with the reflected wave, measurement results displayed on the screen.
  • Page 87: Poe Voltage Test

    3.3.24 PoE Voltage test Click icon to enter PoE voltage measurement Connect a network cable from a PoE switch to the IP tester’s PSE IN port. Connect an IP camera or other PoE using node to IP tester’s LAN port, the PoE voltage and the cable’s pin connection status show on the screen.
  • Page 88: Power Input Test

    3.3.25 12V power input test Connect 12V power adaptor to tester’s charging port, then click icon “PoE” to enter voltage measurement app, screen show the current adaptor input voltage and power. Note: the current 12V input measured power is the battery charging power and the device working power, the measured power will change depending on the different of battery power and backlight brightness.
  • Page 89 1) SYMBOLS: U:DC Voltage Measuring A:DC Current Measuring Ω:Resistance Measuring :Diode Testing :AC Voltage Measuring :AC Current Measuring :Continuity Testing :Capacitance Measuring AC/DC Voltage and current measurement state display Auto- range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative...
  • Page 90 a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/Ω” jack. b.Select , enter the DC voltage measurement. c. the tester default Auto range status ,by click “DC auto range” , press the key can select manual range and restore auto range .
  • Page 91 a. Connect the black test lead to the “COM ” jack and the red test lead to the “mA” jack for a maximum of 660mA current. For a maximum of 10A, move the red lead to the 10A jack. , enter the DC current measurement,the screen display“DC current ”, can select manual b.select range;...
  • Page 92 b. select , enter the AC current measurement, manually select the range c. Manual range: 0.000mA → 6.600mA range 00.00mA → 66.00mA range 000.0mA → 660.0mA range → 10.00A range(use 10A socket) 00.00A Note: ◆ When only the figure “OL” is displayed, it indicates over range situation and the higher range has to be selected.
  • Page 93 Ω a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/ ” jack. Ω b. to select Ω, enter the measurement he tester default Auto range status, Press the key manually select range ,Press “NEAR” to restore “Auto range”...
  • Page 94 a. Connect the black test lead to the “COM” jack and the red test lead to Ω the “V/ ” jack. (the red lead anode “+” ) b. to select , enter the diode testing. c. Connect test red lead across to the anode, the black lead to the cathode of the diode under testing.
  • Page 95 d. Before connect test leads across two sides of the capacitor under measurement, be sure that the capacitor has been discharged fully. Note: The capacitance of a capacitor should be tested separately, should not test in the installation of circuit. To avoid electric shock, be sure the capacitors have been discharged fully before measuring the ca pacitance of a capacitor.
  • Page 96: Optical Power Meter ( *Optional )

    The hold function and the relative value be combined use, the display value is yellow. The meter protection ➢ Voltage protection You can’t input the voltage which more than 660V AC, it’s possible to show higher voltage, but it’s may destroy the inner circuit. ➢...
  • Page 97 Relative power value (optical link loss) measurement While testing, set the wavelength for measurement. Click “relative”(difference) to test, the tester Auto save current fiber power value as the base reference value. Input another optical fiber to be measured, the displayed new measurement and relative value is red color. Press it again to quit. Page.92.
  • Page 98: Visual Fault Locator ( *Optional )

    Data hold and Relative measuring use together, the data is yellow while the function is effect. 3.3.28 Visual Fault Locator ( *Optional ) Click icon to enter VFL four status can select——“Steady mode”, “Evasive 1Hz”,“Evasive 2Hz”and “ Time off ”. Click button “Steady mode”...
  • Page 99 mins, 60 mins and 120 mins). Click” Steady mode”, red laser source emits steady, click again to quit. Click icons “Evasive 1Hz” or “Evasive 2Hz” to enter pulse mode, the red laser source is emitted by a certain frequency, press it again to quit. Page.94.
  • Page 100: Audio Record

    3.3.29 Audio Record Connect an audio device to the IP tester’s audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop, and the unit will prompt you to save the recording . 3.3.30 Data monitor Pls click icon to enter...
  • Page 101: Audio Player

    Engineer can analyze the protocol and check the data through the displayed code. 3.3.31 Audio player Click the icon to enter. The audio player only supports MP3 format Audio files. 3.3.32 Media Player Click the icon to enter The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4 and MKV.
  • Page 102: Rtsp Player

    To rename or delete an existing file, press the file name for a few seconds until the screen below appears. You can then rename or delete the file by pressing the desired option. 3.3.33 RTSP Player The RTSP Player app will allow you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video.
  • Page 103: Hik Test Tool

    Local IP: This is the IP testers IP address. RTSP Add: This is where you can manually enter the IP camera’s RTSP URL or click on Search to search the network for cameras that use an RTSP stream. IPC Username: Enter the IP camera’s user name. IPC Password: Enter the IP camera’s password.
  • Page 104 1. Hikvision activation: When connect the unactivated Hikvison camera to the tester, it will auto identify and display “Unactivate” at safety mode. Select needed activate the camera, click bottom right corner button “Enable”, pop-up “the camera have not been activated, activated now”? 2.
  • Page 105 3. Confirm activation After activating the camera, the program default modifies the camera IP. Activated multiple cameras in the local area Network, and pop-up menu to modify IP, improve project efficiency. Play: Display image from the camera. Modify network information: Change the camera IP address, sub-net mask and gateway etc. Page.100.
  • Page 106: Dahua Test Tool

    Modify user information: Modify the camera's user name and password. Factory Reset: Camera factory reset 3.3.35 Dahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera, it can display image, modify IP, user name and password etc. Making Dahua camera test more convenient and quickly.
  • Page 107 Click “DH” icon to enter Dahua test tool. Select the camera of the online detection menu, if the camera support non-verification login, you can click “play” directly, and view the image. Pop up stream menu, select Mainstream or Substream to test. Page.102.
  • Page 108 If the camera not supports non-verification login, pls select “camera” of online detection menu, and input correct user name and password, then click “log in”. After logging successful, you can test it. Play: Select Mainstream or Substream, IP camera live video display. Modify network information: Modify camera parameter, such as ip address, subnet mask, gateway etc.
  • Page 109 Modify user information: Modify camera user name and password, which is onvif, Dahua test tool, IPC TESTE user name and password, not web user name and password. Factory reset setting: Camera will be soft reset, and the device’s user name, password and network set be saved.
  • Page 110: Update

    3.3.36 Update Copy the downloaded update file to SD card "update" directory, if no directory, please create one. icon to open the Update menu. Select “Local Update” to update via the SD card or Click the select “Online Update” to check for updates on the internet. If there are update programs, applications will be listed in the interface, click related applications, update to the latest version.
  • Page 111: Office

    3.3.37 Office Quick office app (support excel, word, ppt format) doc. editable 3.3.38 LED Flashlight It is convenient for the installation or maintenance in the evening or in the dark. Click icon enter. While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If you don’t press the red button to shut off the lamp and press the button to exit the app, the lamp will stay on.
  • Page 112: Browser

    3.3.39 Browser Click icon to enter Type in the camera’s IP address and press “Go” to access the IP camera’s interface. NOTE: You will not be able to view live video in the web browser. For viewing video, use the IP tester’s live camera view Apps.
  • Page 113: System Setting

    pls click to view the notepad , all saving contents display. Click each record bar to show the details. Press the record bar for several seconds, prompt whether delete it. 3.3.41 System Setting Click icon to enter Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish,Spanish, French or Japanese.
  • Page 114 IP setting: Manually set the IP address, Sub-net Mask, Default Gateway and DNS address or select “Dynamic allocation” to use DHCP. To test multiple network segments, click “Advanced ” and then click “Add ” to enter another IP address for the IP tester. After setting an advanced IP address (refer to the photos above), the unit can test two network segments (192.168.5.0) and (192.168.1.0).
  • Page 115 Wi-Fi hotspot: Input “SSID” name and “password”, and then click “ok” to create Wi-Fi hotspot. Brightness: Set the desired brightness of the IP tester and adjust the sleep time settings. Volume: Set volume level. SD Card: Displays SD Card Capacity. You can also format the SD card or unmount it before removing FTP server: Once the IP tester connects to a network, a computer can be used to read the SD card files via FTP.
  • Page 116 Start the FTP server and then input the tester’s FTP address in the PC’s address bar. This will enable the PC to read, copy and edit the files from the SD card without the use of SD card reader. Version information: Shows applications version information, if press any apps icon several seconds to uninstall.
  • Page 117: File Explorer

    Lock Screen: The meter default is not locked. You can choose password Lock screen, pattern Lock screen or “NO”. Password Lock Screen: Set password, you can input digitals, letters or characters as password, input it again to confirm .when the meter is in standby mode or turn it on, you can input your password to enter. Pattern Lock Screen: Drawing a pattern to lock.
  • Page 118 Browse It includes Music, Videos, Pictures, Documents, zip file etc. It is convenient to view and manager. FTP server You can choose internal or external SD card. Other operation details, Pls refer to FTP settings. Page.113.
  • Page 119: Theme

    3.3.43 Theme Click Theme icon to enter themes setting. Desktop style : You can select Lite mode or normal mode. Theme: Pressing square area’s any color icon several seconds, the selected color icon will be auto move the rectangle area, if you press selected color several seconds, and it will be auto deleted. Theme colors include fixed order and random order, and click “set”...
  • Page 120 Set as desktop background: Setting color as desktop background. Set as application background: Set color as application background. Set at the same time: Setting color as desktop background and application background. Cancel: Cancel current setting. Picture: Click Picture to select one, and set as temporarily background to view setting effect. Click “more” to select pictures from local file, and click set to set picture as background.
  • Page 121: Audio Test

    3. 4 Audio test You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP tester with the supplied audio cable. 3.5 HDMI output The built in HDMI output port can output live video from an analog or IP camera, recorded files, media files and images to HDTV monitors.
  • Page 122: Dc12V 3A Power Output

    c. The instrument’s PoE maximum power output is 90W. If Ultra- high-power load happens, the tester will enter protection mode . 3.7 DC12V 3A power output When the IPC tester is turned on, the DC 12V power output ON by default. The smaller end of the supplied converter cable connects to the tester’s DC12V/3A OUTPUT and the other end connects to the camera’s power input.
  • Page 123 Application Power output function is mainly used in the camera field demonstration and testing, meanwhile, for some cameras installation sites, If there is no power outlet for the adapter to power the camera, the tester can offer temporary power for it. But we do not suggest tester supply power for a long time. Notice: Don’t input any power into the “DC12/2A OUTPUT”...
  • Page 124: Specifications

    4. Specifications 4.1 General Specifications Model CS-H9F-80HX Display New 8 inch retina touch screen cctv tester , 2048*1536 resolution Network port 10/100M/1000M auto adjust, RJ45 Built in WIFI,speeds 150M, allows you to connect to a wireless network WIFI and view IP cameras H.265 Mainstream...
  • Page 125 1 channel CVI input(BNC interface, resolution support 720p CVI video signal test * 25,30,50,60fps/ 1080p 25,30fps /2560x1440p 25fps,30fps,3840 x 2160 (Optional) 12.5/15 fps UTC control and call OSD menu 1 channel TVI input(BNC interfce),resolution support 720p TVI video signal test 25,30,50,60fps/ 1080p 25,30fps /2048x1536p 18,25,30fps/ 2688x1520p (Optional)...
  • Page 126 Support RS485 control, Baud 600-115200bps, Compatible with more than PTZ control 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc Output one channel PAL/NTSC color bar video signal for testing monitor or Color bar generator video cable.(red, green ,blue, white and black color) Test UTP cable connection status and display on the screen.
  • Page 127: Multi-Meter Specifications

    Capacitive touch screen, OSD menu, select your desired language: English, Operation setting Chinese, Korean, Russian, Italian, Polish,French, Japanese etc Auto off 1-30 (mins) General Working -10℃---+50℃ Temperature Working Humidity 30%-90% 264mm x 182mm x 43mm / 1Kg Dimension/Weight 4.2 Multi-meter specifications Counts:-6600~+6600 Conversion rate: 3times/s Current modes for clamp meter with ZERO function...
  • Page 128 6.600V ±(0.8%+6) 66.00V 10mV 660.0V 100mV DC current Range Accuracy Resolution 6.600mA ±(0.5%+3) 66.00mA 10uA 660.0mA 100uA ±(1%+5) 10.00A 10mA AC current Range Accuracy Resolution 6.600mA ±(0.5%+3) 66.00mA 10uA 660.0mA 100uA ±(1%+5) 10.00A 10mA Resistance Range Accuracy Resolution 660.0Ω 0.1Ω ±(0.8%+5)...
  • Page 129 Continuity Range Resolution Function The measurement value less 30Ω±3Ω,the tester will 660.0Ω 0.1Ω sound Diode Range Resolution Function Schottky diode:0.15~0.25V 2.0V rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V Capacitance Range Accuracy Resolution ±(0.5%+20) 6.600nF 66.00nF 10pF 660.0nF 100pF ±(3.5%+8) 6.600μF 66.00μF 10nF 660.0μF 100nF 1μF...
  • Page 130: Optical Power Meter Specifications

    4.3 Optical power meter specifications -70~+10dBm Measure Range(dBm) Wavelength(nm) 850nm,1300nm,1310nm,1490nm,1550nm,1625nm Detector InGaAs <±3%dB(-10dBm,22℃) <±5%dB(full range,22℃) Uncertainly Display Resolution Linear:0.1% ; Nonlinear:0.01dBm Operating Temperature(℃) -10~+50 Storage Temperature (℃) -20~+70 Connector type FC/PC 4.4 Visual fault locator specifications Laser type Wavelength Calibration 650nm Output power 5mW(Optional 10mW, 20mW)...

Table of Contents