Sharp LC-20AV1U Service Manual page 49

Lcd color tv
Hide thumbs Also See for LC-20AV1U:
Table of Contents

Advertisement

Main CBA Top View
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE: CBA AND PWB MEANS PRINTED WIRING BOARD.
TP300
GND
WF10
PIN 14 OF
IC801
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK
OF FIRE, REPLACE ONLY WITH SAME TYPE 4A, 125V FUSE.
ATTENTION: UTILISER UN FUSIBLE DE RECHANGE DE
4A/125V
MÊME TYPE DE 4A, 125V.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
WF4
WF5
WF6
PIN 1 OF
PIN 3 OF
PIN 5 OF
CN103A
CN103A
CN103A
8-21
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT, AN ISOLATION TRANSFORMER MUST BE USED.
ALSO, IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY, WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT, A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
TP401
+21V
VR601
+21V
8-22
BL0370F01011-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-20sh1u

Table of Contents