Download Print this page

Rishabh RISH HVT 5KV AC Instruction Manual

High voltage tester

Advertisement

Quick Links

Instruction Manual
High Voltage Tester
Rish HVT 5kV AC
RISHABH INSTRUMENTS LTD
0253 2202162
service@rishabh.co.in
www.rishabh.co.in
F-31, M.I.D.C., Satpur,
Nashik - 422 007
Maharashtra, India

Advertisement

loading
Need help?

Need help?

Do you have a question about the RISH HVT 5KV AC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rishabh RISH HVT 5KV AC

  • Page 1 Instruction Manual High Voltage Tester Rish HVT 5kV AC RISHABH INSTRUMENTS LTD 0253 2202162 service@rishabh.co.in www.rishabh.co.in F-31, M.I.D.C., Satpur, Nashik - 422 007 Maharashtra, India...
  • Page 2 This document or any part of it may NOT be reproduced, transmitted, stored, or translated in physical or electronic form without the consent of Rishabh Instruments Ltd. Rish HVT 5kV AC carries a warranty of 12 months from the date of purchase. RISH HVT 5KV AC Instruction Manual...
  • Page 3 RISH HVT 5KV AC’s diode/capacitor/HV Transformer. 11. Ensure that any item/circuit to undergo testing using RISH HVT 5KV AC is only connected or disconnected when RISH HVT 5KV AC’s high voltage is off.
  • Page 4: Safety Advice

    14. The warranty will become invalid if RISH HVT 5KV AC is opened by the customer. Safety Advice Hazardous voltages occur in RISH HVT 5KV AC during operation. Violation or disregard of safety instructions may result in damage to property, severe physical harm or even death.
  • Page 5 Manual Cooling Air Cooled 2.4 Environmental Specification Operating temperature: 0 to +55°C Storage temperature: 0 to +70°C Relative humidity: 0... 90% non-condensing 2.5 Applicable Standards  IEC 61010-1  IS 2071-1 for testing techniques RISH HVT 5KV AC Instruction Manual...
  • Page 6 (HT ON) also has a buzzer inside it. The push buttons HT ON & HT OFF are of illumnated type (containing lamp within) and indicate whether the test is ON or OFF. RISH HVT 5KV AC Instruction Manual...
  • Page 7 3.1 Potentiometer RISH HVT 5KV AC is equipped with a potentiometer to select the maximum tripping current which linearly goes from 10 mA to 100 mA for 100mA model & 10 mA to 50 mA for 50 mA model. Pressing the...
  • Page 8 3.3 Indicators The RISH HVT 5KV AC test kit is equipped with 7 indicators – 4 LED lamps, 1 buzzer, 1 illuminated push button & 1 illuminated power inlet switch. The following table describes their purpose. Indicator Color Position Meaning...
  • Page 9 “mA trip”. By pressing this button, the meter will show the set tripping current set by potentiometer in 3.1. Hence, while setting the current setting, the user can use this button to set the desired tripping current. - Used to shift 1 digit to left. RISH HVT 5KV AC Instruction Manual...
  • Page 10 The following steps must be followed in order. Please ensure that the both the device under test (DUT) and RISH HVT 5KV AC are powered OFF and earthed while creating the following connections and also while removing the mentioned connections.
  • Page 11 4) After completion of the test and turning the power supply off of the RISH HVT 5KV AC and discharging objects under test, ensure removing of all the accessories like cables, etc. RISH HVT 5KV AC Instruction Manual...
  • Page 12 5 . S u p p l i e d A c c e s s o r i e s 1) HV Cable (3 mtr). 2) Power supply cable. 3) Earthing Cable Furthermore, these accessories are also provided: 1) Spare fuse (1 Nos). 2) Operation Manual (Soft copy). 3) Warranty Certificate. RISH HVT 5KV AC Instruction Manual...
  • Page 13 5 . S u p p l i e d A c c e s s o r i e s Storage: RISH HVT 5KV AC must NOT be stored or used outdoors, or in any place where it may be subject to rain, thunder, excessive water vapor or explosive chemicals. Also...