Download Print this page

Infinite L-COM SRAQ-G014 User Manual page 2

Flammable gas sensor module

Advertisement

Technical Parameters
Working Voltage
Working Current
Gas Detection
Detection Concentration
Preheating Time
Response Time
Recovery Time
Output Mode
Work environment
Electrical Diagram
VCC is the 0  5 VDC power supply positive and negative; GND is the ground
Aout is the analog output, Dout is the level output
On the PCB, Indicator light on: Dout is low level. Indicator light off: Dout is high level
The 1k resistor shown on the PCBA is the load resistance (RL), it can be changed by user. Due to the sensor itself the load resistance range
should be 100k  1M.
Mounting Diagram
Mount the PCBA to the enclosure with screws. Hole diameter 3mm, pitch distances as per the diagrams given below.
50  10000 ppm (Flammable gas), 10  1000 ppm (CO)
Aout (Analog signal)
Dout (Level signal)
Temperature
Humidity
2
5 VDC ± 0.2 V
<150 mA
Flammable Gas, CO
>30 mins
≤1 sec
≤30 sec
0  5 V (non-linear)
Low level: 0V; High level: 3.7V
-10~50 °C
<95% RH