Kenwood TS-130S Service Manual page 33

Hf ssb transceiver
Hide thumbs Also See for TS-130S:
Table of Contents

Advertisement

TS-130SV
ADJUSTMENTS
PREPARATION
Unless otherwise specified, set the controls as follows.
POWER...
...ON
SEND/REC
... .REC
AFGAIN
..... COUNTERCLOCKWISE
NB...
2. ee. OFF
RF GAIN
..... FULL CLOCKWISE
FIX./VFO..... VFO
Caution:
|
|
RITSW....... OFF
VOX/MAN..... MAN
3.3V is required if
IF SHIFT
CENTERED
PROC
OFF
BSK40(L)
or (K)
mo
are used in the RF
NODE....... SSB
WIDE/NAR
... .WIDE
unit(Q1,3,4)
and
IF unit(Q2~4).
(V): TS-130 V type
(S): TS-130 S type
.
Measuring point
Adjust
.
Item
Condition
Test
Unit
Terminal
Unit
Parts
Reference
Specifications/Remarks
equipment
1. Power Supply
DC VTVM|AF-GEN
J4,7P
| AF-GEN
3.8V
voltage
J4,4P
VR3
OV
J4,5P
50V
J4,10P
| AF-GEN
VR2
2.8V
STBY:SEND
Filter
AVB
Filter
VR4(V) | 11.0V
VR5(S)
2. CAR
BAND:3.5
1) CAR output)
STBY:REC
RF VTVM
|AF-GEN
J3,2P
| CAR
T1
0.3Vrms
0.3V+1dB
2) Freq. RX
1F SHIFT:
Centered
MODE:SSB
Frequency
TC2
8.82850MHz
MODE:REV _ | counter
TC1
8.83150MHz
MODE:CW
Frequency | AF-GEN
J3,2P
| CAR
VR2
8.83070MHz
STBY:SEND _ | counter
3. IF SHIFT
MODE:SSB
Frequency
|AF-GEN
J3,2P
| CAR
VR1
8.82850MHz
RX and TX frequency no change.
STBY:Alter-
| counter
nate
SEND/REC
4. VFO
1) Output
VFO scale:250 | RF VTVM
/AF-GEN
J1,6P
VFO
TC2
0.2Vrms
0.2V+1dB rms
2) 800Hz
MODE:CW
Frequency
L4
Adjust for
800+ 50 Hz
shift
STBY:SEND
| counter
800 Hz higher
than receive
state.
3) Frequency
| VFO:50
L3
5550.00k Hz
Repeat this adjustment several
tracking
Set the CAL
+200 Hz
times untill the frequency is
and check
| control to the
within specification.
index.
VFO scale:
TC1
5950.00 kHz
Approx. 450
+ 200 Hz
Set the CAL
control calibra-
ted under this
VFO setting ex-
actly to the
index.
The 50 kHz point on the dial scale
must be aligned to the index.
Set the VFO main tuning to 5750.000 kHz.
Under the above condition, set the CAL
0
5.5MHz | Within £2kHz
control to the index. Turn the main tuning,
100
5.6
100 kHz point.
500
6.0
Set the CAL control back to 250 under the
Less than
Backlash
above condition (do not turn excessively.),
400Hz
then further set back the CAL control to 0
with respect to the frequency at 250 to check
The defference from the reference frequency.
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts-130vVf0-120At-130Ps-30

Table of Contents