Download Print this page

Advertisement

Quick Links

Advertisement

loading

Summary of Contents for Jasper A-1DB-N

  • Page 2: Installation Instructions

    Simco Group Holdings Pty Ltd Simco Group Holdings NZ Ltd Models: JA-1DB-N JA-2DB-N JA-3DB-N JA-1CB-N JA-2CB-N JA-3CB-N JA-1DB-L JA-2DB-L JA-3DB-L JA-1CB-L JA-2CB-L JA-3CB-L INSTALLATION INSTRUCTIONS UNIT TO BE INSTALLED BY LICENSED TECHNICIAN ONLY REFER TO DATA PLATE FOR GAS TYPE, GAS CONSUMPTION AND PRESSURE DETAILS OVERALL DIMENSIONS Height over splashback 1180 mm (depending on leg adjustable)
  • Page 3: Water Connection

    The installer must set up the device according to AS/NZS 5601, local authority, gas and any other relevant statutory regulations. Try to confirm whether the product is fitted in a non-flammable location near the unit where you can. Approval from flammables walls sides right and left 350mm, approval from the back of 150mm, approval from the top of 1500 mm.
  • Page 4 NOTE: One must also mount this device on foldable legs as provided. You must adjust the gas pressure as per the information on the data plate when the product is in a working state. If you are unable to adjust this product to work properly, contact the local official supplier or reach out to the manufacturer.
  • Page 5 Simco Group Holdings Pty Ltd Simco Group Holdings NZ Ltd OPERATION INSTRUCTIONS Lighting up of Appliance with separate pilot and flame failure valves: 1. Check that you've switched on the isolating gas cock. The isolating valves 1 to each product are on the wirings underneath the item. 2.
  • Page 6: Operation

    OPERATION WATER TAP OPERATION To use the water feature on the wok table, we have given a valve operated by knee on the control panel on the front area of the product. The water will come out of the swivel outlet placed on the control panel by moving the lever to any side.
  • Page 7 Simco Group Holdings Pty Ltd Simco Group Holdings NZ Ltd SERVICE INSTRUCTIONS ONLY AUTHORISED PERSONNEL TO SERVICE APPLIANCE 1. Try to regularly clean the burners. Regularly check whether there is any spillage. Maintain healthy flame by keeping burner injectors tidy. 2.
  • Page 8 6. Turn the pilot adjustment screw on either the flame failure valve or the combination valve anti-clockwise to adjust the pilot. The anti-clockwise motion will enhance the flame length, and the clockwise decrease the flame length. 7. Measure the gas pressure with the equipment running. Besides, confirm the information matches the points on the data plate.
  • Page 9 Simco Group Holdings Pty Ltd Simco Group Holdings NZ Ltd Cleaning 1. Clean the work surfaces of the device,regualarly at the end of each day.Do not use wire brushed on the work surfaces.Clean using a mild detergent and a hot water solution using a soff bristled brush.Dry the device thoroughly using a dry clean cloth.
  • Page 10 Simco Group Holdings Pty Ltd Simco Group Holdings NZ Ltd FAULT FINDING SERVICE CHART FAULT CAUSE REMEDY No gas to burner Supply turned off or depleted. Check supply, service pipe under size. Orifice blocked. Clean orifice with drill or wire smaller than orifice diameter.