Advertisement

Quick Links

PSEN cs2.2p
}
PSEN sensor technology
Operating Manual-1003368-EN-10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSEN cs2.2p and is the answer not in the manual?

Questions and answers

Summary of Contents for Pilz PSEN cs2.2p

  • Page 1 PSEN cs2.2p PSEN sensor technology Operating Manual-1003368-EN-10...
  • Page 2 We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Lateral and vertical offset......................Wiring ............................Terminal assignment connectors....................Connection to evaluation devices ..................Single connection ........................Series connection ........................Connection to Pilz evaluation devices ..................Teaching in the actuator ....................... Installation ..........................Adjustment ..........................Operation ..........................Dimensions in mm .........................
  • Page 4 Contents Accessories ..........................EC declaration of conformity ....................UKCA-Declaration of Conformity ..................Operating Manual PSEN cs2.2p 1003368-EN-10...
  • Page 5: Introduction

    PSEN cs2.2p Introduction Validity of documentation This documentation is valid for the product PSEN cs2.2p from Version 2.0. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Using the documentation This document is intended for instruction.
  • Page 6: Safety

    If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN cs2.2p 1003368-EN-10...
  • Page 7: Safety Regulations

    Are familiar with the basic regulations concerning health and safety / accident prevention, Have read and understood the information provided in the section entitled Safety Have a good knowledge of the generic and specialist standards applicable to the specific application. Operating Manual PSEN cs2.2p 1003368-EN-10...
  • Page 8: Warranty And Liability

    – If the original actuators are replaced with substitute actuators, the ori- ginal actuators must be destroyed before disposal. Do not remove the connector's protective cap until you are just about to connect the unit. This will prevent potential contamination. Operating Manual PSEN cs2.2p 1003368-EN-10...
  • Page 9: Unit Features

    PSEN cs2.2p Unit features Transponder technology for presence detection Pilz coding type: uniquely coded Dual-channel operation 2 safety inputs for series connection of multiple safety switches 2 safety outputs Safety Device Diagnostics (SDD) – Safety Device Diagnostics can be used to retrieve sensor information on one or more sensors, to perform actions and to read and write configuration parameters –...
  • Page 10: Safety Device Diagnostics

    – Read configuration parameters of the sensor (examples: Number of teach-in pro- cesses remaining, serial number of the sensor) – Perform actions (example: poll updated actuator name) Operating Manual PSEN cs2.2p | 10 1003368-EN-10...
  • Page 11: Operating Distances

    Further information on Safety Device Diagnostics can be found in Additional documents that apply [ Operating distances Legend: : Assured operating distance: 15 mm : Typical operating distance: 21 mm : Typical release distance: 32 mm : Assured release distance: 40 mm Operating Manual PSEN cs2.2p | 11 1003368-EN-10...
  • Page 12: Lateral And Vertical Offset

    PSEN sg or PSEN sl) or – The faults at the safety inputs that can occur by shorts across contact will have to be excluded by suitable measures (e.g. wiring in accordance with EN 602041). Operating Manual PSEN cs2.2p | 12 1003368-EN-10...
  • Page 13: Terminal Assignment Connectors

    0 V UB blue Diagnostics input The wire colour also applies for the cable available from Pilz as an accessory. Connection to evaluation devices Make sure that the selected evaluation device has the following property: OSSD signals are evaluated through 2 channels with plausibility monitoring...
  • Page 14: Single Connection

    Also note the max. current (see Technical details [ 24]). Single connection Connection diagram, single connection without SDD Safety switch Actuator Evaluation device FS: Failsafe Operating Manual PSEN cs2.2p | 14 1003368-EN-10...
  • Page 15 PSEN cs2.2p Connection diagram, single connection with SDD 24 V Actuator Safety switch I1 (FS) I2 (FS) Evaluation device Fieldbus module FS: Failsafe Operating Manual PSEN cs2.2p | 15 1003368-EN-10...
  • Page 16: Series Connection

    – PSEN ix2 F4 code – PSEN ix2 F8 code – PSEN Y junction M8-M12/M12 PIGTAIL – PSEN Y junction M12-M12/M12 PIGTAIL – PSEN Y junction M12 SENSOR – PSEN Y junction M12 cable channel Operating Manual PSEN cs2.2p | 16 1003368-EN-10...
  • Page 17 High signals must return at the inputs on the evaluation device (e.g. S11, S21 or I1, I2). Repeat the test for each gate. If the input signals do not react as described above, check and rectify the wiring and carry out the test again. Operating Manual PSEN cs2.2p | 17 1003368-EN-10...
  • Page 18 PSEN cs2.2p Connection diagram, series connection without SDD Safety switch 1 Actuator Controller Safety switch 2 Actuator Actuator Safety switch n Evaluation device FS: Failsafe Operating Manual PSEN cs2.2p | 18 1003368-EN-10...
  • Page 19 PSEN cs2.2p Connection diagram, series connection with SDD 24 V Safety switch Actuator Actuator Safety switch Actuator Safety switch I1 (FS) I2 (FS) Evaluation device Fieldbus module FS: Failsafe ST: Standard Operating Manual PSEN cs2.2p | 19 1003368-EN-10...
  • Page 20: Connection To Pilz Evaluation Devices

    PSEN cs2.2p Connection to Pilz evaluation devices The safety switch PSEN cs2.2p can be connected to Pilz evaluation devices, for example. Suitable Pilz evaluation devices are, for example: PNOZelog for safety gate monitoring PNOZpower for safety gate monitoring PNOZsigma for safety gate monitoring...
  • Page 21: Teaching In The Actuator

    Safety switches and actuators should be permanently secured using M5 safety screws with a flat head (e.g. M5 cheese-head or pan head screws). Protect the actuator from contamination. Torque setting: Please note the information provided under Technical details [ 24]. Operating Manual PSEN cs2.2p | 21 1003368-EN-10...
  • Page 22 Make sure that the actuator with the printed side points towards the marking on the sensor. 5. Do not fully tighten the second screw on the actuator. 6. Align the safety switch and tighten the screws. 7. Align the actuator and tighten the screws. Operating Manual PSEN cs2.2p | 22 1003368-EN-10...
  • Page 23: Adjustment

    (partial operation). Remedy: Open both channels of the input circuit. "Power/Fault" LED lights up red: Error message Remedy: Rectify fault and interrupt power supply. Dimensions in mm Safety switch 21,5 Operating Manual PSEN cs2.2p | 23 1003368-EN-10...
  • Page 24: Technical Details

    Inputs Number Voltage at inputs 24 V DC Input current range 5 mA Max. overall cable resistance Rlmax Single-channel at UB DC 1000 Ohm Semiconductor outputs Number of OSSD safety outputs Signal outputs Operating Manual PSEN cs2.2p | 24 1003368-EN-10...
  • Page 25 93 % r. h. at 40 °C EN 60947-5-3 Vibration In accordance with the standard EN 60947-5-2 Frequency 10 - 55 Hz Amplitude 1 mm Shock stress In accordance with the standard EN 60947-5-2 Acceleration Duration 11 ms Operating Manual PSEN cs2.2p | 25 1003368-EN-10...
  • Page 26 Height 11 mm Width 40 mm Depth 40 mm Weight of safety switch 130 g Weight of actuator 20 g Weight 150 g Where standards are undated, the 2016-10 latest editions shall apply. Operating Manual PSEN cs2.2p | 26 1003368-EN-10...
  • Page 27: Safety Characteristic Data

    A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PSEN cs2.2p | 27 1003368-EN-10...
  • Page 28: Supplementary Data

    2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 29 M12, 8-pin, socket M12, 8‑pin, pin M12, 8- 540338 M12 PIGTAIL pin, socket PDP67 F 4 code Decentralised passive junction 773603 PDP67 F 4 code VA Decentralised passive junction, V2A ring nut 773613 Operating Manual PSEN cs2.2p | 29 1003368-EN-10...
  • Page 30 European Parliament and of the Council. 2006/42/EC on machines 2014/53/EC on radio equipment The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/ downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany...
  • Page 31 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...

This manual is also suitable for:

540200540180