Page 2
Contents 1. Safety Guidelines .......................... 3 Safety guidelines for proper use: ...................... 3 Caution! .............................. 4 2. Introduction ............................ 4 3. Scope of Delivery .......................... 4 4. Specifications ............................... 5 5. Features .............................. 6 6. Operation ............................... 6 DMX Control Modes (DMX Addressing) .................... 6 Manual Control Mode ........................... 7 AUTO CHANGE MODE .......................... 7 ...
Page 3
• This product is designed for indoor-use only • Warranty becomes void when DC4DIN is dismantled or changed in any way • Only a specialist is allowed to repair the product • To prevent fire and electric shocks, protect product from water and moisture ...
Page 4
Thanks you for buying our product. Check the product and packing for transportation damage* Read the user manual carefully, before starting up the DC4DIN. The unit is used as a signal channel dimmer/DMX decoder. Maximum load 3A, per single channel output.
Page 5
4. Specifications Power Supply 12-24V DC ( 2-pin Connector V-,V+) Power 6-pin Connector (2x V+, R,G,B,W) 3A / Channel -> 36W/12V DC ges. 3A x4 Channel = max. 12A/144W 3A / Channel -> 72W/24V DC ges. 3A x4 Channel = max. 12A/288W IP Rate IP20 Input Signal...
Page 6
5. Features DMX to RGBW converter that can be used with any DMX512 controllers according to USITT standard The controller can be operated with a maximum loading power of 12A/288W Easy address setting via DIP switches ...
Page 7
Manual Control Mode In this mode, the DIP switch 10 is set to "OFF". Put the dip switches 1 through 8 for the pre-programmed color sequences to activate. Each dipswitch represents a binary value. DIP SETTING MODE DIP 1 7 8 9 OFF DIP10=1;...
Page 8
Supplier: illuminFx Lighting Systems Rochester New York 14606 www.illuminfx.com (585) 254-8010 ...
Need help?
Do you have a question about the DC4DIN and is the answer not in the manual?