C a t a l o g u e KVM60 00 TABLE OF CONTENTS 1 Preface 2 Description of AC drive 2.1 Description of the label of AC drive 2.2 Description of model 2.3 Description of serial number 2.4 Product standard specification 3 Technical Specifications 4 Mechanical Dimensions of AC Drive 5 Main Circuit Connection Functions...
1. Pr ef a ce V1.0 Thank you for using the KVM6000 series high-performance current vector control AC drive. Please carefully read this manual before the installation in order to ensure the correct installation and operation of the AC drive, give full play to its superior performance, and ensure safety.
2.1 Description of th e l a b e l o f A C d r i ve MODEL:KVM6000-04D0G05D5P43A AC drive Model Input power Spec. MODEL: KVM 6000- 04D0G05D5P43A INPUT: 3PH 380-480V 50-60Hz Output power Spec. OUTPUT: 3PH 0-Vin 0.1-320Hz...
D e s c r i p t i o n o f A C d r i v e KVM60 00 2 . 4 Pr o d u c t standard specification Voltage Voltage 220V 38 0V Rated output current(A) Rated output current(A)...
T e c h n i c a l S p e c i f i c a t i o n s KVM60 00 3. Technical S p ec ifica ti ons Item Specifications • Vector control: 0–300 Hz Maximum frequency •...
Page 7
T e c h n i c a l S p e c i f i c a t i o n s KVM6000 Item Specifications It can limit the torque automatically and prevent fre- Torque limit and quent over current tripping during the running process. control Torque control can be implemented in the CLVC mode.
Page 8
T e c h n i c a l S p e c i f i c a t i o n s KVM600 0 It e m S peci fic at i o n s Expanding capacity: 1 DO terminal Output terminal 1 relay output terminal 1 AO terminal that supports 0–20 mA current output or...
KVM60 00 M e c h a n i c a l d i m e n s i o n o f A C d r i v e 4. Mec h a n i ca l dimension of AC d r i v e A Structure Installation Hole B Structure...
Page 10
KVM60 00 M e c h a n i c a l d i m e n s i o n o f A C d r i v e 2 2 0V Class Power Installation Structure ( m m ) (Kw) Hole 0.4Kw...
O p e r a t i o n a n d d i s p l a y KVM60 00 Type Function Description Terminal Name Digital input 1 S1-COM Digital input 2 S2-COM 1. Optocoupler coupling isolation, compatible with dual Digital input 3 S3-COM polarity input...
KVM600 0 F a u l t s a n d s o l u t i o n s 7.2 Description of LED operation panel indicators Description Description Indicator Indicator ST OP motor STOP motor RUN motor reverse rotation motor forward rotation JOG state control source as panel...
Page 14
KVM600 0 F a u l t s a n d s o l u t i o n s 4: Manual torque boost or V/F 4: Adjust the manual torque boost or V/F curve is not appropriate. curve. 5: The input voltage is too low. 5: Adjust the voltage to the normal range.
Page 15
KVM60 0 0 F a u l t s a n d s o l u t i o n s 5: The drive board is faulty. 5: Contact technical support. Undervoltage 6: The main control board is Err09 6: Contact technical support. faulty.
Page 16
KVM600 0 F a u l t s a n d s o l u t i o n s Encoder 3: The encoder is damaged. 3: Replace the damaged encoder. Err20 4: The PG card is faulty. 4: Replace the faulty PG card. fault EEPROM 1: The EEPROM chip is damaged.
KVM600 0 F u n c t i o n C o d e T a b l e 9.F unc t ion Code Table P0 Standard Parameter group Function Setting Range Parameter Name Default Address Code 0: heavy load rating (G) → constant torque AC drive rated application P0-00...
Page 18
KVM600 0 F u n c t i o n C o d e T a b l e Digital setting of 0.01~Maximum output frequency auxiliary P0-09 50.00Hz 0009H source Y frequency Maximum output 0.00~320.00Hz 50.00Hz P0-10 000AH frequency Source of 0: Set by P0-12 1: AI1 2: AI2...
KVM60 0 0 F u n c t i o n C o d e T a b l e P1 Motor parameters Function Setting Range Parameter Name Default Address Code 0:No auto-tuning 1:Asynchronous motor stationary auto-tuning Motro 2:Asynchronous motor (rotational)complete Auto-tuning P1-00 0100H...
KVM60 0 0 F u n c t i o n C o d e T a b l e q-axis inductance 0.001mH~65.535mH Model P1-19 0113H dependent (synchronous (AC Drive>55kW) motor) P1-20 Reserved 0115H Back EMF Model (synchronous P1-21 0.1V~6553.5V 0114H dependent motor)
Page 21
KVM60 0 0 F u n c t i o n C o d e T a b l e Speed loop proportional P2-04 1~100 0204H gain 2 Speed loop P2-05 0.01~10.00s 1.00s 0205H integral time 2 Switchover P2-03~ maximum frequency P2-06 10.00Hz 0206H...
KVM600 0 F u n c t i o n C o d e T a b l e Field weakening automatic 10~500% 100% 0216H P2-22 adjustment gain Field weakening P2-23 2~10 0217H integral multiple P 3 V/F C o n t r o l P a ra me te r s Function Setting Range Parameter Name...
KVM60 0 0 F u n c t i o n C o d e T a b l e Voltage acceleration P3-16 0.0~1000.0s 10.0s 0310H time of V/F separation Voltage deceleration 0 V~r at ed m o to r v o lt a g e P3-17 0311H time of V/F...
Page 24
KVM60 00 F u n c t i o n C o d e T a b l e 39:Frequency source switchover terminal1 40:Frequency source switchover terminal2 41:Frequency source switchover terminal3 42:Frequency source switchover terminal4 S7 terminal P4-06 0406H 43:Command source switchover terminal 1 function 44:Command source switchover terminal 2 45:Counter input terminal...
Page 25
KVM60 0 0 F u n c t i o n C o d e T a b l e BIT0: Terminal of coast to stop recovery mode 0: Restore the original instruction after invalidation 1: Do not restore the original instruction after invalidation BIT1: Terminal of emergency stop recovery mode...
KVM60 0 0 F u n c t i o n C o d e T a b l e 11:Current 1 reached 12:Current 2 reached Y4 terminal P4-23 0417H 13:Zero current output function 14:Output current out of limit 15:Torque limited 16:OL1 motor overload pre-warning 17:OL2 AC drive overload pre-warning Y5 terminal...
Page 27
KVM60 0 0 F u n c t i o n C o d e T a b l e AI2 input voltage P5-06 0.00~10.00V 0.00V 0506H minimum value AI2 input voltage lower limit P5-07 0.00~100.00% 0.00% 0507H corresponding setting AI2 input voltage P5-08 0.00~10.00V...
KVM60 00 F u n c t i o n C o d e T a b l e 15: PUL input value 16: Module temperature HDO output 17: Internal temperature P5-31 051FH selection 18: Excitation quantity 19: RS485 communication settings BIT0: AO1 signal selection 0:0~10V 1:4.00~20.00mA...
KVM60 0 0 F u n c t i o n C o d e T a b l e Initial frequency P6-08 0.00 50.00Hz ~ 0.00Hz 0608H of stop DC braking Stop DC P6-09 0 150% ~ 0609H braking current Waiting time of P6-10 0.00 60.00s...
Page 30
KVM60 00 F u n c t i o n C o d e T a b l e BIT0: Panel digital potentiometer setting selection 0: Invalid 1: Main frequency 2: Auxiliary frequency 3: Upper frequency MF.K Key 4: V/F separated voltage 5: PID setting P7-03 function 0703H...
KVM60 0 0 F u n c t i o n C o d e T a b l e Accumulative power Read-only P7-16 consumption 0~655.35 million kWh 0710H (10000 kWh) Accumulative power Read-only P7-17 0~9999kWh 0711H consumption BIT0: 0: Stop 1: Run AC drive status Read-only...
Page 32
KVM600 0 F u n c t i o n C o d e T a b l e Frequency detection P8-17 50.00Hz 0811H value (FDT2) Detection P8-18 0:Second 1:Minute 2:Hour 0.00Hz 0812H range of FDT2 Detection range of P8-19 frequency 3.0Hz 0813H...
KVM60 0 0 F u n c t i o n C o d e T a b l e P9 Fault and pr otection paramete r s Function Setting Range Parameter Name Default Address Code BIT0:Motor overload protection selection 0:Invalid 1:Valid BIT1:Ground fault duringpower-on...
Page 34
KVM60 00 F u n c t i o n C o d e T a b l e 15 -- ERROR_EXTERNAL EQUIPMENT 16 -- ERROR_COMMUNICATE 17 -- ERROR_CONTACTOR 18 -- ERROR_CURRENT_DETECTION Read-only P9-05 0905H 19 -- ERROR_AUTO-TUNING fault type 20 -- ERROR_ENCODER 21 -- ERROR_EEPROM_READWRITE 22 -- ERROR_HARDWARE_AC DRIVE...
Page 35
KVM60 0 0 F u n c t i o n C o d e T a b l e AC drive status Read-only P9-18 Same as P9-09 0912H upon 2nd fault S terminal status Read-only P9-19 Same as P9-10 0913H upon 2nd fault Y terminal status...
Page 36
KVM600 0 F u n c t i o n C o d e T a b l e Over-speed P9-41 0.0~60.0s 1.0s 0929H detection time Detection value of P9-42 too large speed 0.0~50.0%(Maximum frequency) 20.0% 092AH deviation Detection time of P9-43 too large speed 0.0~60.0s...
KVM60 0 0 F u n c t i o n C o d e T a b l e BIT2: Power on time arrival (Err29) action selection Same as BIT0 BIT3: Load loss (Err30) action selection Protection 0: Immediately-stop, fault alarm P9-52 action 0934H...
Page 38
KVM60 00 F u n c t i o n C o d e T a b l e Feedback PA-04 0.00~10.000 1.000 0A04H signal gain Feedback 0~65535 PA-05 1000 0A05H signal range BIT0: Feedback feature selection 0: Positive characteristic when the feedback signal of PID is less than the given value, the output frequency of AC drive will rise.
Page 39
KVM60 0 0 F u n c t i o n C o d e T a b l e PID setting PA-14 0.00~650.00s 0.00s 0A0EH change time PID feedback PA-15 0.00~60.00s 0.00s 0A0FH filter time PID output PA-16 0.00~60.00s 0.00s 0A10H filter time...
KVM60 0 0 F u n c t i o n C o d e T a b l e Wake-up base PA-35 0.0~6500.0S 30.0s 0A24H duration PB C om m u n i c a t i on c on tr o l fu nc ti o n p a r a m e t e rs Function Setting Range Parameter Name...
KVM60 00 F u n c t i o n C o d e T a b l e BIT2: The third set of transmission frame selection Master send Ditto PB-08 0031 0B09H selection BIT3: Selection of the fourth set of trans- mission frames Ditto PC Optimization Parameters...
KVM600 0 F u n c t i o n C o d e T a b l e PD Inte r na l c on tr ol PLC F un ctio n an d f re q ue ncy par ame ter s Function Setting Range Parameter Name...
Page 43
KVM60 0 0 F u n c t i o n C o d e T a b l e Running time of PD-17 10.0 0D11H PLC reference 2 Running time of PD-18 10.0 0D12H PLC reference 3 Running time of PD-19 10.0 0D13H...
Page 44
KVM60 00 F u n c t i o n C o d e T a b l e Running direction and acceleration/ PD-34 0000 0D22H deceleration time of PLC reference 4 Running direction and acceleration/ PD-35 0000 0D23H deceleration time of PLC reference 5 Running...
KVM60 0 0 F u n c t i o n C o d e T a b l e Running direction and acceleration/ PD-43 0000 0D2BH deceleration time of PLC reference 13 Running direction and acceleration/ PD-44 0000 0D2CH deceleration time of PLC reference 14...
KVM60 00 F u n c t i o n C o d e T a b l e PF parameter PF-02 3~66 0F02H group length PF-03 0F03H Edit definition ~ ~ by user PF-67 0F27H A0 T or q u e c o n tr ol p a ra me t er s Function Setting Range Parameter Name...
KVM60 0 0 F u n c t i o n C o d e T a b l e Torque given A0-06 0.0~10.00 0.10 1006H filter time A0-07 1007H ~ Reserved ~ A0-09 1009H Forward maximum frequency in 0 .0 H z~m a xi mu m f re q u e n cy A0-10 50.00Hz 100AH...
KVM60 00 F u n c t i o n C o d e T a b l e Timing rotation 0.00~maximum frequency A1-07 50.0Hz 1107H frequency limit Timing rotation the A1-08 quantity of rest ~ 1108H motors Add pump 0.00~maximum frequency A1-09 48.00Hz...
Page 49
KVM60 0 0 F u n c t i o n C o d e T a b l e Actual output U-09 2119H frequency Target torque U-10 211AH Output torque U-11 211BH Output excitation U-12 211CH Power factor angle U-13 211DH PID setting...
Page 50
KVM60 00 F u n c t i o n C o d e T a b l e Target voltage upon V/F U-42 213AH separation Output voltage U-43 213BH upon V/F separation Encoder U-44 213CH feedback speed Linear speed U-45 213DH Synchronous motor...
POWER ~ INPUT KVM-6000 S h ield e d cab le (C lose to AC dri ve gro und term i nal ) Note2 (G ro un d re sis ta nce < 10 Ω)...
Page 52
S t a n d a r d w i r i n g d i a g r a m KVM60 00 Note :1、When installing DC reactor, be sure to remove the short connector between terminals ;KVM6020 and below structure without terminal.