Fault
E:32-00 will light up
alternately or indicator
for water supply lights
up.
E:34-00 will light up
alternately.
E:61-02 will light up
alternately.
Cause and troubleshooting
Remove the filter from the supply hose
5.
Clean the filter.
6.
Re-insert the filter in the supply hose.
7.
Screw the water connection back on.
8.
Check the water connection for leaks.
9.
Restore the power supply.
10.
Switch the appliance on.
11.
Water is continuously running into the appliance.
Turn off the water tap.
1.
Call Customer Service → Page 51.
2.
Not an appliance fault. Wastewater pump is blocked
or the cover of the wastewater pump is loose.
Clean the wastewater pump.
1.
→ "Clean wastewater pump", Page 50
Secure the cover of the wastewater pump so it
2.
clicks into position.
→ "Clean wastewater pump", Page 50