Model G10 - Graphite
Touchscreen Operator Interface Terminal
Installation Guide
FOR USE IN HAZARDOUS LOCATIONS:
U L
Class I, Division 2, Groups A, B, C, and D
C C
US
US
R
Class II, Division 2, Groups F and G
LISTED
Class III, Division 2
IND.CONT. EQ.
T4
E302106
E317425
See the Red Lion website at www.redlion.net for full user manual,
®
Crimson
software and software manual.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that
appear in this document or on equipment must be observed to
ensure personal safety and to prevent damage to either the
device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should
ever be designed to be responsible for the maintenance of
personnel safety or consequential equipment not equipped with
safeguards. Red Lion disclaims any responsibility for damages,
either direct or consequential, that result from the use of this
equipment in a manner not specified.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
WARNING - EXPLOSION HAZARD - Do not disconnect
equipment unless power has been switched off or area is
known to be non-hazardous.
WARNING - EXPLOSION HAZARD - Substitution of
components may impair suitability for Class I, Division 2
DIMENSIONS In inches [mm]
10.84 [275.2]
8.57
[217.7]
®
II 3 G Ex ic nA IIC T4 Gc
II 3 D Ex tc IIIC T135°C Dc
≤60°C
-20°C≤T
AMB
DEMKO 14 ATEX 1387X
IECEx UL 15.0035X
UL23UKEX2879X
Series 10" Color
Ex ic ec IIC T4 Gc
Ex tc IIIC T135°C Dc
For G10C0000 and G10C100 only.
ORDERING INFORMATION
DESCRIPTION
10" Color Touch Screen, Indoor Use
10" Color Touch Screen, Indoor Use, Additional Ethernet Port
10" High Resolution Display, Color Touch Screen, Indoor Use
10" High Resolution Display, Color Touch Screen, Indoor Use,
Additional Ethernet Port
10" Color Touch Screen, Indoor/Outdoor Use
10" Color Touch Screen, Indoor/Outdoor Use, Additional
Ethernet Port
* These products have obtained CCC certification.
SPECIFICATIONS
POWER:
Input Voltage (V)
Typical Power HMI only (W):
Maximum Power HMI only (W):
Available Power for Modules (W):
Max Power HMI with Module(s) (W):
Must use a Class 2 circuit according to National Electrical Code
(NEC), NFPA-70 or Canadian Electrical Code (CEC), Part I, C22.1
or a Limited Power Supply (LPS) according to IEC/EN 60950-1
2.06 [52.4]
2.97 [76]
Module sold
separately
1
Bulletin No. G10-H
Drawing No. LP0909
Revised 11/2023
G10C/R
10
24
30
10
11
11
15
16
17
29
44
46
47
11.1 [281]
(MOUNTING CLIPS INSTALLED)
PART NUMBER
G10C0000 *
G10C1000 *
G10R0000
G10R1000
G10S0000
G10S1000
G10S
10
24
30
15
16
16
20
21
22
29
50
51
52
8.8
[224]
Need help?
Do you have a question about the Graphite G10C and is the answer not in the manual?
Questions and answers