INSTALLATION INSTRUCTIONS
Step 3. Slide the R1 insulation panel into the side
curtain, the side with pattern should facing the indoor
side.(Fig.13).
Fig.13
Step 4. Repeat on the other side.
INSTALL WEATHER STRIPPING (only
7
applicable to Energy Star models )
In order to minimize air leaks between the room air
conditoner and the window opening,t rim the weather
stripping to the proper length, peel off the protective
backing and plug any gaps if needed (Fig.14).
Fig.14
If AC is Blocked by Stor m Window
Add wood as shown in Fig.15, or remove storm
window before air conditioner is installed.
If Storm Window Frame must remain, be sure the
drain holes or slots are not caulked or painted shut.
Accumulated rain water or Condensation must be
allowed to drain out.
Removing AC From W indow
Turn AC off, and disconnect power cord.
Remove sash seal from between windows, and
unscrew safety sash lock.
Remove screws installed through frame and frame-
lock.
Remove the R1 Panel and close (slide) side panels
into frame.
Keeping a firm grip on air conditioner, raise sash
and carefully remove.
Be carefully not to spill any remaining water while lifting
unit from window. Store parts with air conditioner.