Hp-ib isolated dac power supply programmer
Hide thumbs Also See for 59501B:
Table of Contents

Advertisement

NOTE: The dotted line connections represent jumpers which must be removed. All other jumpers must be installed.
HP POWER SUPPLY
(64 27B - 6448B, 6464C -6483C )
J30
TERM
CURRENT „
(PROGRAMS
OUTPUT
VOLTAGE
OF
SUPPLY )
* OPTION
80
J30 PC 30
(VOLTAGE-
TO-CUR-
RENT CON¬
VERTER
J
* FACTORY INSTALLED SPECIAL
OPTION (J30) REQUIRED ON
POWER SUPPLY (SEE PARA 3-48)
## MAY BE USED IN PLACE OF
POWER SUPPLY'S VOLTAGE
CONTROL
595018
I-
jZERO ADJUST |
©
ai
y^\
(+)
Figure 3-10. CV Programming Connections for HP Power
Supply Models 6427B-6448B and 6468C-6483C
HP POWER SUPPLY
(6453A, 64568, OR 6459A)
59501B
Figure 3-11. CV Programming Connections for HP Power
Supply Models 6453A, 6456B, and 6459A
HP POWER SUPPLY 6464C **
595018
X
INTERNAL JUMPER (DESIGNATED R7 ON SCHEMATIC IN 6464C
OS S MANUAL) MUST BE REMOVED.
** VOLTAGE PROGRAMMING WITH UNITY GAIN-6464C OUTPUT
VOLTAGE VARIES IN A 1 TO 1 RATIO WITH 5950IB PROGRAMMING
VOLTAGE.
Figure 3-12, CV Programming Connections for HP Power
Supply Model 6464C
BIPOLAR POWER SUPPLY
AMPLIFIER
(SEE TABLE BELOW)
5950IB
MODEL NO.
AMPLIFIER
INPUT
TERMS
REMARKS
A
8
6823A,24C
CS
IN
SET FRONT PANEL MODE SWITCH
TO AMPLIFIER.
6825A,26A,
27A
A 2
AI
SET FRONT PANEL MODE SWITCH
TO VAR GAIN AMP.
SET RANGE
SWITCH TO DESIRED OUTPUT
RANGE.
Figure 3-13. CV Programming Connections for Bipolar
Power Supply Amplifiers 6423A, 6824C, 6825A-27A
3-9