5. RF AGC
Adjustment Parts
Checking Point
R190
• Connection Method
MAIN PCB
• Adjustment Procedure
1) Turn on the VCR. Tuning CH21 (471.25MHz)
2) Connect the signal generator output (PM5418 pattern Gen) to ANT INPUT of RF102 (Modulator)
3) Connect the oscilloscope to JPT02
4) Adjust R190 to obtain 6.0±0.2V DC.
Measuring Equipment
Oscilloscope
JPT02
PM5418 Gen
RF OUT
PM5418
Modulator ANT IN
RF102
RF101
JPT02
R190
RF103
RF Signal : PAL B/G (Color Bar or 100% white)
CH : 21 CH (471.25MHz)
UHF BAND
Input Level : 60 dBµV (I)
63 dBµV (B/G)
(75 ohm Loaded)
Condition of Adj.
EE Mode