HEAD
ADJUSTMENT
A
EL
REC ANGLE
PS ANGLE
tea)
a)
Ga
3. HEAD ANGLE ALIGNMENT
if
| |
ADJUSTMENT (Refer to Fig. 10)
1) Playback Head
a. Connect a High Sensitivity AC Voltmeter to the
left and right channel Output Terminals of the
tape deck.
b. Set the Track Selector to STEREO and set the
machine to 7-1/2 ips tape speed.
c. Playback
an
8,000Hz
3-3/4 ips alignment
adjustment test tape.
d. Loosen screw (j). Adjust PB angle in the direc-
tion of the arrow and change the angle of the
head-to-tape contact.
Fix the PB head at a position where the output
level is not effected by an additional tension to
the supply reel.
2) Recording Head
a. Connect an Audio Frequency Oscillator to the
a 16,000Hz
sine wave
signal.
Adjust
the
Attenuator or the Line Recording Level Con-
trols to obtain a —20 dBm High Sensitivity AC
Voltmeter indication.
c. Reset Monitor Switch to TAPE and set deck to
recording mode.
1, HEAD HEIGHT ADJUSTMENT
2. HEAD AZIMUTH ALIGNMENT
d. Loosen screw (i). Adjust REC
angle in the
(Refer to Fig. 10)
ADJUSTMENT
(Refer to Fig. 10)
direction of the arrow and change the angle of
1) Erase Head
1) Playback Head
the head-to tape contact.
Loosen screws (a) and (b) shown in Fig. 10 and
adjust erase head height. Tighten screws at posi-
tion at which the upper edge of the tape is 0.1 mm
lower than the upper edge of the left channel head
core of the erase head.
2) Recording Head
Adjust head height adjustment screws (c) and (d)
shown in Fig. 10 so that the upper edge of the
tape and the upper edge of left channel head core
of the recording head are the same height.
3) Playback Head
Adjust head height adjustment screws (f) and (g)
shown in Fig. 10 so that the upper edge of the
tape and the upper edge of left channel head core
of the playback head are the same height.
a. Connect a High Sensitivity AC Voltmeter to
the left and right channel Output Terminals of
the tape deck.
b. Set the Track Selector to STEREO and set the
machine to 7-1/2 ips tape speed.
c. Playback
an
8,000Hz
3-3/4 ips alignment
adjustment test tape.
d. Adjust adjustment
screw (h) to obtain max-
imum High Sensitivity AC Voltmeter indication
on both channels.
2) Recording Head
a. Connect an Audio Frequency Oscillator to the
line input through an Attenuator, and connect
a High Sensitivity AC Voltmeter to the line
output. Then load a blank test tape.
b. Set the Monitor Switch to SOURCE and supply
a
16,000Hz
sine wave
signal.
Adjust
the
Attenuator or the Line Recording Leve! Con-
trols to obtain a —20 dBm High Sensitivity AC
Voltmeter indication.
c. Reset Monitor Switch to TAPE and set deck to
recording mode.
d. Adjust adjustment
screw
(e) to obtain max-
imum High Sensitivity AC Voltmeter indication
on both channels.
Fix the REC head at a position where the out-
put level is not effected an additional tension to
the supply reel.
(e.g. slightly touching the supply reel).
NOTES:
1. As
head
adjustment
greatly affects
tape deck performance, be sure that
these
adjustments
are
carried
out
properly.
. Be careful not to use magnetized tools
near the heads.
. As the level of old tape varies greatly.
use new tape.
4. Demagnetize
heads before and after
head adjustment.