Operating instructions Varitain

4. Operation

If the product is not to be used for an extended period of time, no preparation is required�
A visual inspection before recommissioning is recommended�
Connection only by an electrically qualified person.

4.1. Powering the reefer containers

According to international regulations, the plugs of the reefer containers' cables can only be plugged in and unplugged
when the circuit-breaker is open�
Preparations
Check before connecting:
1
The plug housing is undamaged�
The bayonet ring is available with unspoiled seal�
The plug is clean and dry�
The auxiliary projection of the plug is present�
The plug complies with the valid standards IEC 60309-1, IEC 60309-2�
Connecting the reefer containers
Check if the connection of the reefer container works�
2
Lay the cable to the CEE socket gang�
3
Turn the bayonet cap of the socket counterclockwise
4
and remove it�
Slide the bayonet ring over the bush�
6
Tighten clockwise�
8
PushIn Advance
®
Article-No.: 50108391
Notice Use only approved plugs�
i
Check plug for compatibility before use� Connectors
that comply with the standard are permitted�
No power supply to the CEE socket with other plugs�
Caution
Tripping hazard�
 Lay cables in accordance with IMO regulations in
the intended cable routing zones�
Push the CEE plug firmly into the socket.
5
The LED lights up green�
7
6
Ed. 1.0 – 05/2023