LG LMX30665 Series Service Manual page 48

Table of Contents

Advertisement

9-6 Poor cooling in Fresh food section
No
1
Check the sensor resistance.
<CON7>
The sensor is determined by
the temperature.
For example, 30
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the fresh food door and Check the
air flow.
4
Check the air temperature.
Cold or not ?
Checking flow
indicates 32°F.
Result & SVC Action
Temperature
23°F
32°F
41°F
50°F
59°F
Status
Windy
No windy
Status
Cold
Not cold
- 48 -
Result
°C
38
°C
30
°C
24
°C
19.5
°C
16
SVC Action
Go to the 4
Check the R Fan motor
Check the damper
(Go to the 5)
SVC Action
Explain to customer
Check the Compressor
And sealed system

Advertisement

Table of Contents
loading

Table of Contents