1. Product Overview

As a result of torque measurement and calibration requires strict certification, torque
instruments must possess good temperature, precision, and resolution capabilities, and must
also have the ability to correct for disturbances (ESD and EMI). And while the characteristics
of peripheral components must meet specification requirements, measurement chip
specifications must also meet requirements. Because of this, the simplification of peripheral
passive elements can enable an instrument to accurately measure torque values, which will
not only save cost, but also improve maintenance and assembly quality, and lessen the
chance of damage to the used objects.

2. Product Features

Simple multifunctional operation, vibration resistance, can preset torque value, unit switching,
mode switching, memory & storage, digital up & down increments, power-saving mode, LED
flashing & audible alarm, etc...
2.1 Digital torque, angle degree and default value display.
2.2 LCD backlight display.
2.3 Can be used in both clockwise and counterclockwise directions.
Accuracy: CW±2% (clockwise) CCW±3% (counterclock- wise)
Angle accuracy : ±2° (Angle series)
2.4 Can store 30 memory default values.
2.5 Power saving mode (enters power-saving mode after 2 minutes).
2.6 Have buzzer and LED backlight indicators.
2.7 Low voltage detector (reminds user of battery life).
2.8 Unit : Nm/kgf.cm/lbf.in/lbf.ft
Function and Name for Each Parts
Upper Cover
Unit display
1
11
Down Cover
Memory group display
2
12
Battery cover
F/K/A(Track/Peak/Angle )
3
13
(A mode -
Extension bar
4
square hole
Angle series only)
Extension bar
5
square head
Percentage display
14
Function Button
6
Battery life display
15
LCD display
7
monitor
LED indicators.
8
Buzzer
9
Torque value display
10

3. Technical Specifications

Model Type
General Series
Angle Series
Torque Accuracy*1
CW:±1.5% CCW:±2.5%
Angle Accuracy*2
Max. angle measure
LED Indicator
2 LED(1 Green + 1 Red )
Track(F) / Peak hold(K) / Angle(A)
Operation Modes
Unit
Nm、kgf.cm、lbf.in、lbf.ft
Battery life
48 hrs.
(Continuousoperation)
Battery life
1 year
(Standby Mode)
Up to 90% non-condensing
Humidity

4. Before using the adapter

4.1 Battery installation

4.1.1 Open battery cover.
4.1.2 Insert battery, make sure
polarity is correct.
4.1.3 Replace the battery cover.
4.2 Low Voltage Notification
If the system detects a voltage level of less than 2.3V, a
battery icon will appear at the upper right corner of the
screen, and the system will shut down a few seconds
later.
GTA - Digital Angle Torque Adapter Series
Memory Capacity
30 Sets
OperatingTemperature
-10℃ ~60℃
+/- 2°
Storage Temperature
-20℃ ~70℃
720°
Drop Test
Vibration Test
Life Test
10000 cycle
Environmental test
EMC Test
※ *1 Torque Accuracy:According to ISO6789:2003, a specified measuring
range from 20% to 100% of the maximum torque value of the respective tool.
※ *2 Angle Accuracy:1° for 90° rotation at 45°/sec.
Angle series installs two AAA batteries.
(Can use zinc-carbon or alkaline battery.)
General series install single CR2032 battery.
N-m

5. Product Functions

The function panel have 6 buttons, the
function is as follow:

5.1 Power and Reset

Power ON Press the C button to turn on the wrench. Next, the backlight comes up, and all
the text on the LCD flashes. After displaying 0000 from left to right, the wrench enters into
operation mode.
The adapter horizontally set, press the C key to boot, backlit LCD text full flash, from left to right shows
0000, the adapter automatically detects whether there is to stand still, if such as not standing, LCD from
left to right continuous display 0000, until the adapter is completely static, the four 0 at the same time
display three times, enter the operating mode.
When this product is used for the first time, it will display the product's maximum operating value after
entering the operating mode. The units are preset as N-m, the memory will display the first set, the mode
will be tracking mode T, and the battery scale will show the voltage detected at that time (all 30 memory
data sets will have the same preset value).
Turn Off : Press C key and hold 3 seconds to switch off.
Clear : Press C key to reset (when device turned on).
P.01

5.2 Unit Switching

P.02
This product provides international standard metric units of Nm, metric units of Kgf.cm, and
British units of lbf.in and lbf.ft. The units will change each time the U/S key is pressed, in the
P.03
order of Nm,Kgf.cm, lbf.in, and lbf.ft; the preset units are Nm.
P.03
P.04
P.11

5.3 Memory Function

All memory data sets are preset as the maximum value. To set a memory value, press the
M key, and the digit on the far right of the M-01 display will begin to flash; use ▲ (up) or
▼ (down) to select the memory data set (up and down keys can be held down for
continuous increase or decrease). Press the M key after selected, will stop flash and leave
the function.
P.01
5.4 (F) Mode/ (K) Mode/(A) Mode (Angle Series)
(F) Mode: (preset as tracking mode at time of first use)
After setting a value (assuming the value is 50Nm), the force applied by the wrench
will gradually increase from 0000. When force is applied, the displayed value will
change as the user applies different amounts of force; the reading will increase as
force increases, and decrease as force decreases. The reading will jump to 50Nm
when the user relaxes his grip and lets up.
(K) Mode:
After the value is selected (assuming 50Nm is selected), when the wrench is applied with
force, the value increases from 0000 upwards. When the force is applied by the force, the
displayed value will change according to the force of the applying force, and after the force is
completely stopped, the value is displayed. For the final torque value, flashes for 10 seconds.
After 10 seconds, continue to apply the torque value will automatically accumulate (at this
time, any action and button are invalid). After 10 seconds, no force will continue to return to
the selected value, or press C can be returned to the selected value.
(A) Mode (Angle series):
After setting a degree (assuming is 50°), the force applied by the wrench will gradually
increase from 0°. When the force is exerted, the displayed value will change according to the
angle of the force applied, and the force will stop completely. The display value is the final
angle value and torque value. The angle value and torque value are interactively displayed.
Flashing for 10 seconds. Continue to force the angle value within 10 seconds will
automatically accumulate (in this case, any action and buttons are invalid). After 10 seconds,
no continue to force automatically return to the selected value, if not press C key to clear,
then the next time the force is applied, the angle value will continue to accumulate from the
previous value, until over the selected value will automatically clears the accumulated value,
switch mode and shutdown it also clears the angle accumulated value.
P.02

5.5 Measurement Range Selection

Values can be freely selected as long as force is not being measured or memory selection
has not been performed. After completing torque measurement in either mode, the selected
value can be displayed.
1m
5.6 ▲( U P ) / ▼ ( D O W N ) selection
10 G
Pressing the ▲ (up) key once will cause the value on the far right to increase by one;
pressing the key continuously will cause the value to increase continuously. Pressing the
Pass
▼ (down) key once will cause the value on the far right to decrease by one.
Pass
5.7 LCD Backlights Warning & Buzzers
(There will be a beep each time a key is pressed.)
In Track mode, the two LED light will function as green and red. Assume that the torque
value is set at 20Nm. When the user starts applying force to the wrench, the value changes
from 0000. When the force reaches 80% of the set value, the green light starts to flash, and
the buzzer starts to sound. When the torque value approaches the set value, the green light
flashes faster and the buzzer sounds faster. When the force reaches 100% of the set value,
the green light comes up permanently, and the buzzer sounds continuously. When the force
exceeded the set value(101%) , the red light comes up, and the buzzer continues to sound.
The value decreases when the force applied to the wrench is decreased.
P.03
Button
C
Power & Reset
U/S
Unit Selection
M
Memory Selection
F/K/A
A-Mode (Angle series)
Number Increasing (UP)
Number Decreasing(DOWN)
lb-in
lb-ft
1 lb-in
1
0.083
12
1
1 lb-ft
1 Nm
8.851
0.737
1 kg.cm
0.868
0.072
Function
Mode Switch
P.04
Nm
Kg.cm
0.113
1.152
1.356
13.83
1
10.2
0.098
1
P.05
P.06
P.07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GTA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for M7 GTA Series

  • Page 1 Operator’s Manual Button Function 5. Product Functions Power & Reset The function panel have 6 buttons, the Unit Selection GTA - Digital Angle Torque Adapter Series function is as follow: Memory Selection Mode Switch F/K/A A-Mode (Angle series) ▲ Number Increasing (UP) ▼...
  • Page 2 ※ Method of Use █ Digital Torque Adapter The Peak Mode is similar to the Track mode. However, in Peak Mode, the LED light and the buzzer stops after force applied to the wrench is completely removed. • Please use the correct •...

This manual is also suitable for:

Gta general seriesGta angle series

Table of Contents