Level Calibration
Dolby NR Level Calibration
The Dolby NR standard level (200 nW/m)
of the Nakamichi
1000 is set to 0 dB.
Particularly, when you record with Dolby
NR "In" adjust the OdB signal of the built-in
400 Hz Test Tone to OdB according to each
of the tapes to be used.
'
© Set the position of the Tape Selector
Switch according to the type of the tape in
DRL
= DOLBY NR
MONITOR
aN
uN
TAPE
use.
Aeonioo sen
DOLBYNR
MONITOR
iN
TAPE
Cy
iA
ouT
SOURCE
@ Set the "Monitor Switch" to 'Tape'.
@ If away from OdB, adjust the Tone Cal
Level to obtain the accurate OdB.
If the levels are not within
1 4B of "O
dB", adjust the appropriate
Level
Calibration
Controls
(Left or Right, EX or
SX)
clockwise or counter-clockwise
(Fig.
A or Fig. B) to obtain a O dB reading
on
both
meters.
Note:
The recorder must be in the record mode
with the "Monitor" switch in the "Tape"
position in order to perform this calibration.