VANDAL RESISTANT UTILITY LUMINAIRE
PRODUCT PARAMETER
INPUT VOLTAGE
120-277V
VALIDATION
UL WEL LOCATION, IP65, IK10
SURGE PROTECTION
10Kv SPU INCLUDED
THROUGH WALL WIRING INSTALLATION (Caution: Before beginning installation turn off the circuit breaker and light switch)
FIG. 1
1. Separate the fixture front from the fixture base by loosening the
(4) screws. (Fig. 1)
2. Remove the conduit plug in the back of the fixture base.
FIG. 4
1. Separate the fixture front from the fixture base by loosening the
(4) screws. (Fig. 1)
2. Securely fasten the fixture base to the wall using appropriate
hardware supplied by others.
3. Secure conduit to the fixture base in the desired hole(s). (Fig. 4)
4. Feed wires through the conduit into the fixture base. (Fig. 5)
www.spitzerlighting.com
I N S T A L L A T I O N M A N U A L
•Carefully remove the fixture from the carton.
•Before beginning assembly, installation, or operation of product, make sure all parts are present. Compare parts with package contents
list and diagram on previous page. If any part is missing or damaged, do not attempt to assemble, install or operate the product.
Contact customer service for replacement parts.
• Tools required for assembly (Not Included): screwdriver, phillips screwdriver, pliers, electrical tape, wire cutters, safety glasses, ladder,
wire stripper.
FIG. 2
3. Feed wires from wall through the hole in the back of the fixture
base. (Fig. 2)
4. Securely fasten the fixture base to the wall using appropriate
hardware supplied by others.
THROUGH CONDUIT WIRING
FIG. 5
5. Make electrical connections; see Electrical Connections section.
6. Reattach the fixture front to the fixture base. Alternate screws
and push on the fixture front while tightening the screws to ensure
that the fixture front is fully seated against the fixture base. Ensure
wiring remains within the fixture base and does not get pinched.
(Fig. 3)
702 Interchange Blvd., Newark, DE 19711
SAFETY INFORMATION
BE SURE THE POWER IS OFF! RISK OF ELECTRICAL SHOCK: Always use the switch to power off. Do not perform any operations while
this unit is powered on. The electrical system you want to connect the device to must be grounded. Read the instructions before using
or powering this device. The safety instructions must remain with the unit in case of transfer. Any damage to the device linked to an
inappropriate use is excluded from support by the warranty. Before connecting, make sure that the current and voltage are compatible
with this device. We highly recommend that all installations are made by QUALIFIED ELECTRICIAN. We are NOT responsible by any
means for the use or misuse of the following information. We are NOT responsible in whole or part for any harm or damage that may
or may not be caused. We reserve the right to revise the components of any product, due to part availability or change ETL, CUL, UL
standards without assuming any obligation or liability to modify any products previously manufactured and without notice. These
instructions do not cover all details of variations in equipment, nor do they provide every possible contingency to be met. Turn off /
unplug power when installing or service device.
PRE - INSTALLATION
FIG. 3
5. Make electrical connections; see Electrical Connections
section.
6. Reattach the fixture front to the fixture base. Alternate screws
and push on the fixture front while tightening the screws to
ensure that the fixture front is fully seated against the fixture
base. Ensure wiring remains the fixture base and does not get
pinched. (Fig. 3)
Note: Be careful not to over tighten the screws.
IMPORTANT: Weatherproof your outdoor installation. Be sure
to seal all holes in the enclosure, such as the mounting, con-
duit, plugs, sensors, and photo controls with silicone sealant.
Note: Be careful not to over tighten the screws.
IMPORTANT: Weatherproof your outdoor installation. Be sure
to seal all holes in the enclosure, such as the mounting, conduit,
plugs, sensors, and photo controls with silicone sealant.
Specification is subject to change without notice
1/2

Advertisement

loading
Need help?

Need help?

Do you have a question about the DFU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Spitzer LIGHTING DFU

  • Page 1 VANDAL RESISTANT UTILITY LUMINAIRE I N S T A L L A T I O N M A N U A L SAFETY INFORMATION PRODUCT PARAMETER BE SURE THE POWER IS OFF! RISK OF ELECTRICAL SHOCK: Always use the switch to power off. Do not perform any operations while this unit is powered on.
  • Page 2 VANDAL RESISTANT UTILITY LUMINAIRE I N S T A L L A T I O N M A N U A L ANGLE ADJUSTMENT (Caution: Before beginning installation turn off the circuit breaker and light switch) FIG. 7 FIG. 6 Electrical Connections Universal voltage driver permits operation at 120V - 277V, 50 or 60 Hz.