  • Page 1 TROL2 Digital Agricultural Thermometer USER MANUAL ISO 9001...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION............................3 ACCESSORIES ............................7 DESIGN OF THE DEVICE ........................9 KEYBOARD FUNCTIONS ........................15 INSTRUMENT START-UP ........................17 MEASUREMENT NOTES ........................21 MEASUREMENTS ..........................23 MAIN MENU ............................27 CHANGING BATTERIES ........................37 FINAL REMARKS ...........................39 TECHNICAL SPECIFICATION ......................41...
  • Page 4: Introduction

    INTRODUCTION...
  • Page 5 TROL2 is a response to the expectations of lengths, depending on user needs, while maintaining even the most demanding users who emphasised the...
  • Page 6 By ensuring proper disposal, As a manufacturer, we provide warranty and you help to protect the environment. post-warranty service in Poland. For more information and always up-to-date data please visit www.draminski.pl see more INTRODUCTION...
  • Page 7 SECTION 1 | ACCESSORIES...
  • Page 8: Accessories

    ACCESSORIES SECTION...
  • Page 9 Dramiński TROL2 ACCESSORIES: 1. Operation manual. 4. 4 x 1.5 V batteries type AA, LR6. 2. Electronic Agricultural Thermometer Dramiński 5. Leash with a metal snap hook. TROL2. 6. Shipping packaging. 3. USB – mini-USB cable for communication with a 7.
  • Page 10: Design Of The Device

    DESIGN OF THE DEVICE SECTION...
  • Page 11 EXTERNAL DESIGN TROL2 1. Graphic LCD display with LED backlighting. 6. Mini USB socket with rubber cover. 2. Membrane keyboard. 7. Socket for connecting the temperature probe. 3. Housing made of high quality ABS. 4. Battery compartment cover. 5. Compartment for four 1.5 V AA LR6 type batteries.
  • Page 12 Measuring probe design 8. Probe handle (some measuring probe models are not provided with a handle). 9. Working part of probe (made of stainless steel). 10. Probe end with digital temperature sensor. 11. Transport protection of the measuring probe (adapted to the version of the measuring probe selected from the product range).
  • Page 13 APPROXIMATE DIMENSIONS TROL2 SECTION 2 | DESIGN OF THE DEVICE...
  • Page 14 Available measuring probe models A – Folding probe 3.0 m B – Folding probe 1.5 m C – Non-folding probe 1.5 m D – Non-folding probe 1.0 m (with handle) * it is possible to order another dimension of the probe after consultation with Dramiński S.A. SECTION 2 | DESIGN OF THE DEVICE...
  • Page 15 SECTION 2 | DESIGN OF THE DEVICE...
  • Page 16: Keyboard Functions

    KEYBOARD FUNCTIONS SECTION...
  • Page 17 “Turn off!” option, and if not in use, it will automatically turn off to save batteries). – Turning on the main menu. – Canceling program functions. draminski.com – Accepting program functions. – Preview the mean, the lowest and AGRICULTURAL THERMOMETER the highest indication result.
  • Page 18: Instrument Start-Up

    INSTRUMENT START-UP SECTION...
  • Page 19 Dramiński TROL2 will be ready for use if the compartment menu of the device, use the key). includes properly inserted batteries (note polarity). TROL Switch on the device with the key. 25.6°C a) A welcome message will appear on the display indicat-...
  • Page 20 and the lowest and highest indications. In the “Record” device will pass into standby mode after a period of time, option, it is possible to record the current result, record i.e. the backlight will turn off (this time can be changed in the mean result and reset the mean result.
  • Page 21 ATTENTION! Advanced mode users can download a spe- cial software for communication with a computer from our website www.draminski.pl, which allows for transfer of data from the device to the computer’s hard drive to conveniently and accurately analyse results, archive data, save valuable notes, create special reports, printouts etc.
  • Page 22: Measurement Notes

    MEASUREMENT NOTES SECTION...
  • Page 23 – When the device is switched on, the message “No name – During measurements wait until the indications are sta- found” will appear if the advanced operating mode is ble, which means that the probe has already adopted active (see chapter 7: MAIN MENU) and the connect- the temperature of the tested material and the result can ed probe has not yet been assigned any name (or the be considered final.
  • Page 24: Measurements

    MEASUREMENTS SECTION...
  • Page 25 Temperature measurement: 5. When the probe is connected, the message “Wait!” will appear to indicate that the temperature sensor has 1. Switch on the device and check the display for suffi- been activated. After a few seconds, the temperature cient battery charge. result will appear (reading refreshes every 2 seconds).
  • Page 26 This makes it convenient to view the results in the de- vice menu and upload them to your computer to use the advanced functions to analyse the data collected with special software (the software is free-to-use and available for download on the www.draminski.pl website). SECTION 6 | MEASUREMENTS...
  • Page 27 SECTION 6 | MEASUREMENTS...
  • Page 28: Main Menu

    MAIN MENU SECTION...
  • Page 29 2. Temperature probes Thanks to the functions contained in the main menu of the device, the user can quickly turn off the device, adjust TROL 28.09.2023 TROL 28.09.2023 operational settings to their needs, manage memory and Main menu Temp. probes Turn o ! Add probe much more.
  • Page 30 perature probes/ Rename, then use the key or and confirm with the key or cancel with the key to select the appropriate probe from the list key (Note! the probe and its measurements will be irre- and confirm with the key.
  • Page 31 etc. go to Main menu / Operating mode, then using TROL 28.09.2023 TROL 28.09.2023 Main menu Temp. probes key select the Advanced option and Turn o ! RAPS PROBE NO 13 Temp. probes RAPS PROBE NO 14 confirm with the key, e.g.
  • Page 32 TROL 28.09.2023 TROL TROL 28.09.2023 TROL 28.09.2023 28.09.2023 Settings Language Display Language English Backlight intensity Backlight intensity Display Polski Backlight o time Memory LCD contrast Deutsch Power auto o Français 5.2 Display screen 5.2 b) Backlight off time – adjustment of the time after which the backlight of the display is off and the de- TROL 28.09.2023...
  • Page 33 5.2 c) LCD contrast – to change the contrast of the LCD TROL 28.09.2023 TROL 28.09.2023 display, go to Main menu / Settings / Display / LCD Memory Available memory Available memory Number of probes contrast, then select the appropriate value using Delete temperature re 249 / 250 Erasing memory...
  • Page 34 5.5 Temperature scale tings / Memory / Erasing memory and confirm with key. Note! the data will be irretrievably deleted To change the temperature scale from Celsius to Fahren- from the device, so if the data is important, remem- heit or vice-versa, go to Main menu / Settings / Temper- ature scale, then select the appropriate scale using the ber to first transfer it to the computer using special software.
  • Page 35 5.6 a) Set date – to set the current date, go to Main TROL 28.09.2023 TROL 28.09.2023 Date & time menu / Settings / Date & time / Set date, then Set date Hour Set time use the key to select the appropriate Date notation value and press the key to confirm the year/...
  • Page 36 DRAMIŃSKI S.A. key, e.g. ul. Wiktora Ste ena 21 11-036 Sząbruk, Polska e-mail: dm@draminski.com phone: +48 89 675 26 00 TROL 28.09.2023 TROL 28.09.2023 Date & time Time notation MADE IN POLAND...
  • Page 37 SECTION 7 | MAIN MENU...
  • Page 38: Changing Batteries

    CHANGING BATTERIES SECTION...
  • Page 39 The device features an automatic indication that the bat- – check whether the cover has latched properly into the tery is discharged. In this case, the “Change batteries” container to make sure that it does not slip out. message in the form of a graphic symbol will be displayed immediately after turning on or during use and the device will automatically turn off.
  • Page 40: Final Remarks

    FINAL REMARKS SECTION...
  • Page 41 – The housing can be cleaned with a wet cloth using de- – DRAMIŃSKI S.A. requests to send any comments and in- tergents. Do not use very hot water or boiling water du- form us about the results of using the device. Customer ring washing.
  • Page 42: Technical Specification

    TECHNICAL SPECIFICATION SECTION...
  • Page 43 Approximate reader weight (with batteries) 330 g 1,0 m non-folding – 510 g 1,5 m folding – 770 g, Probe weight (depending on the model) 1,5 m non-folding – 850 g 3,0 m folding – 1760 g reader: 19 x 8 x 7 cm Approximate dimensions measuring probes: 1,0 m / 1,5 m / 3,0 m (depending on the model) Cable length...
  • Page 44 250 names of temperature probes (automatically recognised with the probe ID Memory capacity number). 1.1 million measurements with date and time 20 language versions Memory status check from menu entry Available units °C / °F Measuring range from -55°C to +125°C / from -67°F to +257°F Measurement resolution 0,1 °C / °F Sampling...
  • Page 45 5°C to 45°C Place of manufacture Poland Manufacturer Dramiński S.A. Electronic Agricultural Thermometer TROL2 – 5906874410516 1.0 m probe, non-folding – 5906874410554 EAN codes 1.5 m probe, folding – 5906874410530 1.5 m probe, non-folding – 5906874410523 3.0 m probe, folding – 5906874410547...
  • Page 46 DRAMIŃSKI S.A. Wiktora Steffena 21 11-036 Sząbruk, Poland tel. 89 675 26 00 e-mail: dm@draminski.com www.draminski.com Instr.TROL111023EN1.1...

Table of Contents