Are defined to be tested every temperature probe connected to the electronic.
If the sensor related to the probe detects an acceptable value of temperature:
The display is notified the index.
If the sensor has an interrupt:
The display is notifying and blinking the current temperature index and message failure „Er".
Press the push button „next", to activate the next component.
The push button „action" is not used in these phases.
Pressing the push button „next" again to goes in the next phase

4.9 Software and Parameters

All codes of software and parameters are notified on the display.
The digits shows letter by letter. The digits shows each character in second steps and a short beep from the
buzzer.
Between two different codes a bar is showed on digits for one second.
The push button „action" is not used in these phases.
Pressing the push button „next" again to goes in the next phase

4.10 Life time display

The maximum value can be notified 9999 days. Each number is notified on the display (starting from Most
Significant) if you pressing „next" push button, a short beep from the buzzer device and showing the next
digit.
Pressing the push button „next" again to goes in the next phase.

4.11 Final phase

On the display is notified a time counter in second steps the number 0 to 99.
To return to the normal mode you have to press for 5 seconds the „action" push button which made start the
Service mode.