Summary of Contents for Nihon HSCI-3.6+

  • Page 1 16ch compatible CAN communication device [ HSCI-3.6+ ] Main unit instruction manual 5th : May 16, 2019 NIHON SYSTEM EIGHT CO., LTD. 3-3, Keyakidai, Mito-shi, Ibaraki 310-0842 Japan Tel: +81-29-309-8808, Fax: +81-29-309-8810 SCI Monitor Special Site http://www.insdev.jp/sci/en/...
  • Page 2: Table Of Contents

    Contents 1.Product Summary ______________________________________________________________________________________________ 3 1.1 Overview ___________________________________________________________________________________________________ 3 1.2 functions and features ______________________________________________________________________________________ 3 1.3 Main unit specification _____________________________________________________________________________________ 4 1.4 CPU1 (SH4) Board Specification ______________________________________________________________________________ 4 2.Function explanation _________________________________________________________________________________________ 5 2.1 Front panel description _____________________________________________________________________________________ 5 2.2 Rear panel description ______________________________________________________________________________________ 6 2.3 Connector terminal arrangement ______________________________________________________________________________ 7 2.4 Connection of communication cable ___________________________________________________________________________ 8 2.5 CPU board communication mode ________________________________________________________________________________ 9...
  • Page 3: Product Summary

    1.Product Summary 1.1 Overview This product is a communication interface unit compatible with communication protocols of various ECU. Bidirectional communication with the ECU can be easily done by selecting the communication mode corresponding to the ECU and operating the command by the host computer. 1.2 functions and features 1) High-speed CPU board installed This unit is equipped with a high-speed CPU board to support high-speed processing and improved functions.
  • Page 4: Main Unit Specification

    1.3 Main unit specification 1) Voltage Range : AC100 (±10%) 50/60Hz 2) Power Consumption : 35VA or less 3) Operating Temperature : 5 to 40℃, 20 to 80%RH 4) Dimension : 482.6(W) x 177(H) x 370(D)mm 5) Weight : Approx 6kg 6) Standard Accessory : AC power cable (2m) x 1 piece : Main unit manual and PC side downloader Software storage CD x 1...
  • Page 5: Function Explanation

    2.Function explanation 2.1 Front panel description ⑤ ⑥ ④ ③ ② ① ① POWER It is the power switch of this unit. When power is turned on, the following indicator (②, ⑤) will light for about 2 seconds. ② LINA LINB It is a LIN communication indicator.
  • Page 6: Rear Panel Description

    2.2 Rear panel description ① ② ③ ④ ① AC100V AC power inlet. Connect the supplied AC power cable. ② CAN-M/LIN CAN communication and LIN communication connector. (Dsub-9P female) For the terminal arrangement, refer to "2.3 Connector terminal arrangement". ③ DOUT It is a connector for DOUT.
  • Page 7: Connector Terminal Arrangement

    2.3 Connector terminal arrangement The array of connector terminals mounted on the panel is shown below. 1) SERIAL (Dsub-9P, male, inch screw) Terminal no. Signal name Signal direction Input Input Output Output Input Output Input 2) CAN-M/LIN (Dsub-9P, female, metric screw) Terminal no.
  • Page 8: Connection Of Communication Cable

    2.4 Connection of communication cable When connecting the communication cable to this unit, tighten the plug case screw securely. The CAN/LIN communication cable connector is D-sub9P (male). The DOUT cable side connector is D-sub25P (male). For the plug case for the D-sub connector, please use the following equivalent. 1) Dsub-9P Plug Case Manufacture : Japan Aviation Electronics Industry, Ltd.
  • Page 9: Cpu Board Communication Mode

    2.5 CPU board communication mode (1) CAN communication The following shows how to connect the ECU in the communication mode built into the CPU board. The mode command name for switching from the host to each communication mode is the communication mode name in the following "".
  • Page 10: Ethernet Function

    2.6 Ethernet function Ethernet controller is mounted on the CPU board. Ethernet controller operates as a server function. This server function allows you to perform command communication by connecting to an IP from a personal computer on the network. The factory settings of Ethernet are as follows. Ethernet factory setting ・IP address [192.168.1.14]...
  • Page 11: Inter-Host Communication Monitor Function

    2.7 Inter-host communication monitor function This unit has a monitoring function for communication commands between hosts. The command communication content between the host and this unit can be monitor for each CPU via the following. 1. Via SERIAL 2. Via Ethernet 1.
  • Page 12: About Communication Delimiter

    3.About communication delimiter 3.1 About Ethernet communication delimiter Although the Ethernet communication delimiter is CrLf, an EOF (End Of File) code (1AH) is added to the delimiter of the final message to support multi message transmission and reply. In the case of single message transmission, it is also possible without EOF code. (1)Command Issue(Host→SCI Monitor) ■In case of single message transmission (Normal command) "Transmisson message"...
  • Page 13: About Gpib Communication Delimiter

    3.2 About GPIB communication delimiter The GPIB communication delimiter is CrLf, but EOI (End Of Identify) is added to the delimiter of the final message to support multi message transmission and reply. In the case of single message transmission, it is also possible without EOI code. (1)Command Issue(Host→SCI Monitor) ■In case of single message transmission(Normal command) "Transmisson message"...
  • Page 14: Firmware Update Method

    4. Firmware update method The CPU board of this unit, downloader for the firmware update has been built. The following shows the procedure for firmware update using the downloader. 1) Connect the Ethernet modular jack on the rear panel of the main unit and the PC with a "LAN cable". LAN cable can be used with either "straight"...
  • Page 15 6) Click FileOpen to display the file selection window. Select the program file (SCI3_*.MOT) to be downloaded. (Select the latest Ver.) The program file is in the ¥CPU2-SH4 folder. The selected file name will be displayed in the next window. 7) When a file is selected, the file name is displayed in the following window.
  • Page 16 8) Click DownLoad to start the download. 9) Below is the transition of the screen during downloading. While downloading, the CAN, LIN and ERR indicators blink simultaneously. The download ends in about 30 seconds. 10) Below is the screen at the end of download. 11) Quit the PC side program and turn off the power of this unit.
  • Page 17: Revision History

    6. Revision History Revision Date Description Feb.28,2011 The 1st edition was newly created. May 10,2011 Changed the shipping settings of the Ethernet IP address. (Consideration the link with SCI monitor 3.) Ethernet side 192.168.1.4 ⇒ 192.168.1.14 Ethernet-M side 192.168.1.204(No change) Jun.30,2011 Added SH4 high-speed download function on CPU2 side.