Uniphone UD-60 Basic Installation & Programming Manual

Table of Contents

Advertisement

Quick Links

Installation &
Programming
Manual
UD-60 Basic/Plus
Uniphone Telecommunication Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UD-60 Basic and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Uniphone UD-60 Basic

  • Page 1 Installation & Programming Manual UD-60 Basic/Plus Uniphone Telecommunication Co., Ltd.
  • Page 2: Table Of Contents

    TAB LE OF CONTENTS 1. SYSTEM SPECIFICATIONS AND INSTALLATION ................1 1.1 System Specifications ..........................1 1.2 Available Capacity ...........................2 1.2.1 Total 60 ports when adopting F8001 CPU card ................2 1.2.2 Total 82 ports when adopting F8013 CPU card ................2 1.3 Specification of interfaces/ accessories ....................3 1.3.1 F8007 Digital Station Card (STA-4) ....................3 1.3.2 F8027 Digital Station Card (STA-8) ....................3 1.3.3 F8006 Trunk Card (TRK-4) ......................3...
  • Page 3 2. PROGRAMMING GUIDE ........................22 2.1 Programming Instruction ........................22 2.2 Set to Default Parameter/Value ......................22 2.2.1 Method 1 - By the programming clear code ................22 2.2.2 Method 2 - By DIP Switch ......................22 2.3 Start to Program ............................22 2.3.1 Program by Key Telephone ......................23 2.3.2 Remote Programming via keyphone ....................23 2.4 SYSTEM PROGRAM : Kind 1 ......................24 Kind 1 (11-25) ............................25...
  • Page 4 2.9 FLEXIBLE NUMBER/FUNCTION KEY PROGRAM: Kind 6 ............64 2.9.1 To change the station number .......................64 2.9.2 To change the flexible function number: ..................65 2.9.3 To check the physical location: .....................65 2.10 CALL RESTRICTION PROGRAM: Kind 7 ...................66 2.11 Tone Source / Make Break PROGRAM: Kind 8 ................67 2.11.4 Tone source and default .......................68 Item: 33-56 ...............................69 2.12 TONE SOURCE TIME PROGRAM: Kind 18 .................70...
  • Page 5 5.2 Appendix2: List of Function number and operation code ..............85 F064-F153 ..............................86 F154-F171 ..............................87 5.3 Appendix3 Physical Location of System tone source .................87 5.4 Appendix4 Physical Location, Line No and programed No..............88 UD-60 Basic (F8001 MPU) ........................88 UD-60 Plus (F8013 MPU) ........................89...
  • Page 6: System Specifications And Installation

    1. SYSTEM SPECIFICATIONS AND INSTALLATION 1.1 System Specifications MODEL UD-60 Basic UD-60 Plus Power Source AC 110V-240V, 50/60Hz Power Consumption (except stations) Max. DC Output Power 150W External Back-up Battery 24V/4-50AH Max. Battery Charge Current 27. 6V/0.5A Max. CO + Stations 8 –...
  • Page 7: Available Capacity

    1.2 Available Capacity 1.2.1 Total 60 ports when adopting F8001 CPU card CO Line Key Telephone Station/ Single Line Telephone Station 1. Above “*” capacity of system should install the STA-4 (F8007) or SLT-8 (F8008) station card on 1st~6th slot and 7th or 8th slot. If STA-4 or SLT-8 card is installed on the 7th slot, it must occupy the 7th &...
  • Page 8: Specification Of Interfaces/ Accessories

    1.3 Specification of interfaces/ accessories 1.3.1 F8007 Digital Station Card (STA-4) Item Description Capacity of Each Digital Station Card 4 Loops Maximum Connection Station of Each Loop Parallel connection with 2 stations Maximum Voltage Supply -27.6V Maximum Current Supply 300 mA 100Ω...
  • Page 9: F8016 Trunk Card (Trk-8)

    1.3.4 F8016 Trunk Card (TRK-8) Item Description Capacity of Each Trunk Card 8 Loops 600 Ω Resistance of CO Line Loop Cabling Method 2 wires twist connection A. DTMF Dialing: dialing time & signal is programmable. Dialing Method B. Pulse Dialing: breaking ratio 1:2 Speed 10pps〜20pps Only available when installed F8013 MPU Remark...
  • Page 10: F0854 Voice Mail Card (Vm-4)

    1.3.7 F0854 Voice Mail Card (VM-4) Item Description Loop Number 4 Loops Voice Capacity 2,000 hours Max. Mail Boxes Max. Recording time per mail box 250 sec. Max. Support Languages Max. Companies’ Auto-Attendant 8 Companies Multistage Directories 4 levels 820 sections Storage device Flash Disk / H.D Web Control Panel...
  • Page 11: F8010 Analog Doorphone Card (Dhvr)

    1.3.12 F8010 Analog Doorphone Card (DHVR) Item Description 600 Ω, 1 Loop 2 wires〜4 wires (3 groups) Door phone Interface Electric Lock 1 Loop 3 wires (power included) 1.3.13 STA-SLT Converter Unit (SLT-2DA) Item Description Original STA port 1 port (2B+2D) Converted Loop 2 SLT loops 600 Ω...
  • Page 12: Installation Instructions

    1.4 Installation Instructions 1.4.1 Installation steps 1.4.1.1 Turn the AC power and back-up battery OFF. 1.4.1.2 Make sure the power supply is 100V to 240V or else please install the constant voltage regulator if the voltage instability or exceed the range. 1.4.1.3 To install the external back-up battery.
  • Page 13: After Installation Test

    1.4.5 After Installation Test 1.4.5.1 Turn the power on 1.4.5.2 Check LED indicator of each card/board. In working: The LED indicator keeps 1sec. On 1 sec. OFF repetitively. Faulty or incorrect installation: the LED indicator is OFF. 1.4.6 Troubleshooting Item Trouble Approach Incorrect installation...
  • Page 14: Connection Figure Of Ud-60 System

    Power Switch Fuse Power cable Outlet hole UD-60 Basic (F8001 MPU) P1-P6: Free slot, may installed 4/8 ports card/board, available for all types of card/board. CPU : Specific for MPU card/board (F8001) only. P7-P8: 2*4 ports or 1*8ports card/board. P9 : 4ports card/board.
  • Page 15: Connecting Instruction Of Mpu Card

    1.6 Connecting Instruction of MPU Card 1.6.1 F8001 MPU Card Slot DHVR Total 8 ports or 4 ports 8 ports 8 ports 8 ports 8 ports 8 ports 8 ports 0 port 4 ports Max . Port each slot only Description: BT1: the 3V Lithium Battery –...
  • Page 16: F8013 Mpu Card

    1.6.2 F8013 MPU Card Slot Max . Port 8 ports 8 ports 8 ports 8 ports 8 ports 8 ports 2 ports 8 ports 8 ports 8 ports 8 ports P4: RS-232 Connector P5: Built-in Station port P12: External Radio/CD player P2: Slot Connector Handle...
  • Page 17: Rs-232 Connection

    1.6.3 RS-232 Connection Computer one way simple one way simple metering System two ways connection with handshake metering RS-232 25 pins 9 pins 25 pins 9 pins 25 pins 9 pins CD(1) GND(2) TXD(3) RXD(4) CTS(5) RTS(6) 1.6.4 Digital key telephone A.
  • Page 18: Connecting Instruction Of The Digital Station Card

    1.7 Connecting Instruction of the digital station card 1.7.1 F8007 4-ports (2B+2D) Digital Station Card (STA-4) P2: Station Line port Check wire arrange from here Wiring method 1 Slot Connector Handle Wiring method 2 LED P2: Station line 1-4 Max. installation distance of the digital apparatus Wiring method 1.
  • Page 19: F8027 8-Ports (1B+1D) Digital Station Card (Sta-8)

    1.7.2 F8027 8-ports (1B+1D) Digital Station Card (STA-8) P2: Station Line port Check wire arrange from here Handle Slot Connector P2: Station line 1-8 Max. installation distance of the digital apparatus The wire is Φ0.55mm Wires twist cable STA Terminal Phone Max.
  • Page 20: Connecting Instruction Of Analog Trunk Card And Cid Card

    1.8 Connecting Instruction of Analog Trunk Card and CID card 1.8.1 F8006 4-ports of Trunk Card (TRK-4) CID-4 P2: CO Line port Check wire arrange from here Connect 2,3 wire to Trunk Line Slot Connector Handle LED P2: CO line 1-4 Description: P2 : Connect to trunk line directly.
  • Page 21: F8016 8-Ports Of Trunk Card (Trk-8) For Ud-60 Plus Only

    1.8.2 F8016 8-ports of Trunk Card (TRK-8) for UD-60 Plus only. CID-8 P2: CO Line port 1 2 3 4 5 6 7 8 Check wire arrange from here Slot Connector Handle P2: CO line 1-8 Description: P2 : Connect to trunk line directly. RJ11-1 –...
  • Page 22: Connecting Instruction Of Single Line Telephone Card

    1.9 Connecting Instruction of Single Line Telephone Card 1.9.1 F8008 4-ports / 8-ports of Single Line Telephone Card (SLT-4 / SLT-8) SLT-4 SLT-8 Handle Slot Connector P2: SLT line 1-8 P2: SLT line 1-4 Description: P2: Connect to single line telephone directly. P2: SLT port 4/8 1 2 3 4 5 6 7 8 Check wire...
  • Page 23: Connecting Instruction Of Interface Card

    1.10 Connecting Instruction of Interface Card 1.10.1 F8059 Four-Loops of VoIP card (IP-4) Slot Connector Handle LED10 K3 K2 P8:LAN P4:WAN LED5 Description: P1 : Expanding Card F0658 (VM-4B) P4 : WAN port, LED5,10 will light-on when connecting. P8 : LAN port LED3,4 will light-on when connecting. K2: Press 1sec to initial the IP Card hardware.
  • Page 24: F0854 4-Loops Of Vm Card (Vm-4)

    1.10.2 F0854 4-Loops of VM Card (VM-4) Handle Slot Connector P7:USB Disk P4:WAN Description: P1 : Expanding Card F0658 (VM-4B) P4 : WAN port, LED5,10 will light-on when connecting. P7 : Storage, USB disk K2: Press 1sec to initial the IP Card hardware.
  • Page 25: Connecting Instruction Of Accessories

    1.11 Connecting Instruction of Accessories 1.11.1 STA-SLT Converter Unit (SLT-2DA) INPUT OUTPUT CHANNEL SELECT DIGITAL LINE L0 L1 (L0&L1) (L1) (L2) Description: INPUT: Connected with the digital station port (2 wires) OUTPUT: Connect with the single line phone (normal phone) CHANNEL SELECT: L1- for L1 SLT;...
  • Page 26: Dhu-A7

    Standby: dim Red light Calling: bright Red light C: Screw D: Call Button E: Microphone Uniphone Wiring: P1: Connect to the pin5,6 of P3 of DHVR card. Please switch the wire as (2,1) if LED (B) of the doorphone not light-on (polarity...
  • Page 27: Programming Guide

    Remarks 1: PGM VER 2.XX means "VERSION 2.XX of the system software". It will be updated without notice. Remarks 2: the default digit of Physical location, Line No and programmed No. are 3 digits for UD-60 Plus and 2 digits for UD-60 Basic.
  • Page 28: Program By Key Telephone

    2.3.1 Program by Key Telephone The description of each function key when program by a key telephone PAGE TRAN SPKR HOLD REDIAL To confirm and copy this item to all the downward PAGE Copy of trunk lines or stations; It will return to the original physical location if press “page”...
  • Page 29: System Program : Kind 1

    2.4 SYSTEM PROGRAM : Kind 1 To program the system parameter, class of service, priority, restriction and ring of system. **PGM VER 2.XX** or setting Welcome ISDK SET password screen: Enter Kind Enter Item HOLD Number number Item Description Default Instruction 0: Null (depends on K1 item1,2,60,95) 1: Only active system auto-day/night transfer...
  • Page 30: Kind 1 (11-25)

    Kind 1 (11-25) Item Description Default Instruction 1-9999 ms To press “HOLD” key during set up the speed 11 Pause time 1000 dial number if there’s waiting time (eg. Waiting to press the extension number) on the speed dialling number. 0: 24-hour format 12 Time display format 1: 12-hour format...
  • Page 31: Kind 1 (26-38)

    Kind 1 (26-38) Item Description Default Instruction 0: Circulation (First STA – Last STA) 1: From the 1st STA 2: From the last STA 27 Route for auto-grabbing station 3. Circulation (Last STA – First STA) Related program: K2 item 73, function no.43 164-9999 ms 28 Time units of tone break bit Related program: K8, K18...
  • Page 32: Kind 1 (39-48)

    Kind 1 (39-48) Item Description Default Instruction System speed dialling table for over class Each table has 10 groups, Group "0" is included of service (OCS): 00, 01..09; Group "1" is included 10….19. OCS=0: 0 1 2 3 4 5 6 7 8 9 OCS 0: 0123456789 OCS=1: OCS=2:...
  • Page 33: Kind 1 (46-59)

    Kind 1 (46-59) Item Description Default Instruction 10-9999 x 3.333 ms 49 The longest time of SLT flash The longest flash time when the single line telephone pressed "HOOK"/”FLASH” 0-9999 seconds The duration from dialling the prefix digit to the 50 Detecting time of trunk line dialling last digit of the telephone number.
  • Page 34: Kind 1 (60-70)

    Kind 1 (60-70) Item Description Default Instruction 0: Null (depends on K1 item1,2,60,95) 1: Only active system auto-day/night transfer (not include the station service class) 2: Only active station day/night transfer 3: Auto day/night transfer for system & station service class Relatives programs: K1 item 58,59 60 Day/Night transfer type for holiday The priority of transfer: A.
  • Page 35: Kind 1 (91-105)

    Kind 1 (71-90) Item Description Default Instruction System speed dial + Individual speed dial x 72 Max. numbers of individual speed dialling 0025 Station quantity <= 2000 numbers Related function no. 4, 163 00-63 scales 73 Receiving volume of internal DTMF tone (Standard value: 40, adjusted unit: 1 dB) For remote program: function no.
  • Page 36: Kind 1 (106-120)

    Kind 1 (91-105) Item Description Default Instruction 0:Auto-return to IDLE after active the queuing function, it will ring the queuing station as soon as the communication ended 91 Reserve/Queuing way 1:keep on waiting till the communication end and ringing directly. Application: Enable the caller to queue up a busy station instead of keeping dial the station.
  • Page 37 Kind 1 (106-120) Item Description Default Instruction Unmasked some prefix digits of the called 0~31 digits number while SMDR printing Application: Hotel/hostel/rental apartment that allow to select if print the complete called Masked suffix digits of the called number number. while SMDR printing 0: according to the setup of busy forwarding Incoming directive F168, the waiting time...
  • Page 38: Kind 1 (121-137)

    Kind 1 (121-137) Item Description Default Instruction Phone Book: enter name for the preceding 0: No 90 telephone numbers of dialling plan 1: Yes 0: No 123 Send the DND message to RS-232 1: Yes 0:$TO:04/07/07 20 22 01 1234567 0000 03:11:04 00012 00000 1:$TO:04/07/07 20 22 011234567 0000 03:11:37 00:00:10 2:$TO:04/07/07 20 22 V016 1234567 0000 03:12:22 00008 00000 3:$TO:04/07/07 20 22 V016 1234567 0000 03:13:02 00012 00000...
  • Page 39: Kind 1 (138-167)

    Kind 1 (138-167) Item Description Default Instruction Display FSK name to instead of telephone 0: No (Only display the FSK phone number) number 1: YES 0: No Dial out by PSTN line instead while IP line 1:Yes dial failed Relative program:K1 Item174 Only keep Fur Elise when setting value without Switch Music on hold of built-in DSP 0:012345...
  • Page 40: Kind 1 (168-182)

    Kind 1 (168-182) Item Description Default Instruction 0: No 171 Lighting on the button LED of UHK phone 1:Yes 0: No 173 Active SA/SB function of UHK phone 1: Yes Relative program: K2 Item197 174 PSTN Route while IP line dial failed K3 Item47 181 Auto-reboot time of DSP card 24-hour format...
  • Page 41: Station Line Program : Kind 2

    2.5 STATION LINE PROGRAM : Kind 2 To program the station parameter, or individual ringing tone, class of service and functions. **PGM VER 2.20** or setting password screen: Welcome UD SET Enter Item Enter Kind HOLD number Number Item Description Default Instruction 0: in use...
  • Page 42: Kind 2 (08-20)

    Kind 2 (08-20) Item Description Default Instruction Enter station no. (match to K1 item 23) Press "FWD" key or operation code of function 08 No-answer forwarded station on daytime ---- no. 2 + " 7 " + "station no. " Press "...
  • Page 43: Kind 2 (21-34)

    Kind 2 (21-34) Item Description Default Instruction 0: "MIC" function key OFF 1: "MIC" function key ON 21 Status of manual full handsfree Related function no. 50 Only available for handsfree keyphone and K2 item 20 must to be set at “0” 0: Page/Broadcast 2: Station line 0:….
  • Page 44: Kind 2 (35-49)

    Kind 2 (35-49) Item Description Default Instruction 35 Incoming call ringing group on daytime ..… Default 16 stations Match to K2 item 33-34 36 Incoming call ringing group on nighttime ..… 00-63 scales (standard value: 40, unit: 1dB) 37 Ring volume Related function no.
  • Page 45: Kind 2 (50-65)

    0: No Allow the caller to active the MIC of 1: Yes receiver’s keyphone For Uniphone full handsfree keyphone only. Relative program: K2 Item20,120,151. 0:To recover the default (According to K2 To memorize the adjusted volume during item 103-106)
  • Page 46: Kind 2 (66-83)

    Kind 2 (66-83) Item Description Default Instruction 0: According to the class of service 1: Check Out (Lock class) 66 Check-In/ Check-Out status 2: Check In (Daytime class) Related programs: K2 item 39-41, function no. 62-63 Whether accept daytime/nighttime transfer 0: No after check-in 1: YES...
  • Page 47: Kind 2 (84-97)

    Kind 2 (84-97) Item Description Default Instruction 0: No 1: Yes Related function no. 88, 165 Accept "Hold" from the other party on Application: When the user transfers the call by intercom call holding the line but not transfer the line. It better to connect with display type phone if want to know the caller before answer the call.
  • Page 48: Kind 2 (98-110)

    Kind 2 (98-110) Item Description Default Instruction 0: mute (8) 98 The volume of key sound 7 scales (9-15) To recover the default setting of station by pressing " # " key and then "HOLD" key. 99 To recover the default setting of station ---- Application: When change the different type of keyphone or program disordered happened...
  • Page 49: Kind 2 (111-123)

    Kind 2 (111-123) Item Description Default Instruction 0-9999 x (K1 item 28) 111 Ringing time of called station's ring tone Match to program K2 item 3, 109, 112-114 112 Call to other stations, ringing source 1 The setting value refer to Appendix2 Related programs: K2 item 3, 109, 111-114 113 Call to other stations, ringing source 0 TP:0:0123456789 - >...
  • Page 50: Kind 2 (124-131)

    DSS key) For digital key phone ports only. 0: By Ring 1: By voice calls directly (for Uniphone key phone only) Application: For baby call/listening, 2-ways 128 Ring tone type of incoming call handsfree communication event. It enable to talk directly if adopting handsfree keyphone and K2 item 20 set as “1”;...
  • Page 51: Kind 2 (132-142)

    Kind 2 (132-142) Item Description Default Instruction 0-9999 ms Invalid dialing duration after the intercom 0001 Remark: The last display data will be keeping call is hung up until the setting time is over. 000: Do not implement LCR function 001-009: Select ARS group directly 100-299: Refer to K22 table 300-499: Refer to K23 table...
  • Page 52: Kind 2 (143-161)

    0: Start to communicate after pressing # or F80 156 Push-to-talk button 1: No use 0: No 157 Send the extension describer No. (IP line) 1: Yes Linemex/Uniphone system only 0: No 158 Whether to send the station billing 1: Yes 0: Null 161 Station call restriction...
  • Page 53: Kind 2 (162-193)

    Kind 2 (162-193) Item Description Default Instruction 00-99 groups Recording group of voice mail while on Application: Enable to group the stations into the recording same voice mail group, it will active the group voice mail while the station recording. Application: Enable to store the recording message on a specific station.
  • Page 54: Co/Isdn/Voip Line Program: Kind 3

    2.6 CO/ISDN/VoIP LINE PROGRAM: Kind 3 To program the parameter, class of service, priority, restriction and ring of trunk line. **PGM VER 2.XX** or setting Welcome ISDK SET password screen: CO line HOLD Item Kind 3 HOLD number Item Description Default Instruction 0: In use...
  • Page 55: Kind 3 (12-21)

    Kind 3 (12-21) Item Description Default Instruction 0: No (If connect CO line to another PBX) 1: Yes 12 Outward call restriction Related program: K1 item 33-38, K2 item 38-41. 0: Switch to "transfer" status (for conference call) While hunting a new CO line, hang up the 1: Auto hang up (The original line will hang up if last hunted CO line press new CO line key)
  • Page 56: Kind 3 (22-31)

    Kind 3 (22-31) Item Description Default Instruction According to flexible number plan (K6). Application: Enable the station user to grab the 22 Busy call forward on daytime ---- next designated idle CO line when the user pressed a busy CO key. This function is similar to the station call forward.
  • Page 57: Kind 3 (32-41)

    Kind 3 (32-41) Item Description Default Instruction 00-63 scales (standard value: 40, unit: 1 dB) Application: To adjust the transmission volume while active the CO-CO call forwarding Transmission volume of CO to CO call forwarding Volume Trunk P BX Trunk Adjus tment 00-63 scales (standard value: 40, unit: 1dB) Application: To adjust the transmission volume...
  • Page 58: Kind 3 (42-55)

    Kind 3 (42-55) Item Description Default Instruction 00-63 scales (standard value: 40, unit: 1dB) 44 Volume of DTMF dialling Application: If DTMF signal of CO line is too high or too low. 00-63 scales (standard value: 40,unit: 1dB) Application: If volume of incoming call is too high or too slow.
  • Page 59: Kind 3 (56-75)

    Kind 3 (56-75) Item Description Default Instruction 0/1: Detect by hardware 56 A/u Law type 2: u Law 3: A Law The system should be installed Caller-ID 57 Telephone no. of MSN (1) card (CID) 58 Telephone no. of MSN (2) Application: When the users accept some 59 Telephone no.
  • Page 60: Kind 3 (76-97)

    Kind 3 (76-97) Item Description Default Instruction Setting value: 0-16 84 The starting digit of Caller-ID It will not send the digit when the value is “16”. 0 1 2 3 4 5 6 7 8 9 *:11 #:12 A:13 B:14 C:15 D:10 Application: when the local CO incoming type 85 The ending digit of Caller-ID 1: 5...
  • Page 61: Kind 3 (98-120)

    Kind 3 (98-120) Item Description Default Instruction 0: No (call out directly without check) 1: Yes Remark: Firstly to pick the CO line and dial the Check ARS group while dialing out by number to execute LCR, the system will route to assigned CO line and also execute LCR the setting data and hang up the call if the number is on prohibited table.
  • Page 62: Kind 3 (121-138)

    Kind 3 (121-138) Item Description Default Instruction 0: Hot line 121 Day Class of VoIP trunk mode 1: Intercom only 122 Night Class of VoIP trunk mode 2-7: Match to K 1 item 33-38, function no. 15 0: Not allow 123 Whether allow to active VoIP page/broadcast 1: Allow 124 Daytime Group of IP card...
  • Page 63: Doorphone Program: Kind 4

    2.7 DOORPHONE PROGRAM: Kind 4 To program the parameter, class of service, priority, restriction and ring of doorphone. **PGM VER 2.XX** or setting Welcome ISDK SET password screen: Doorphone Item HOLD Kind 4 HOLD number Item Description Default Instruction 00 Usage status of doorphone 0: in use 1: Null 0: None 1: DTMF 2: Pulse 01 Dialling type...
  • Page 64: Kind 4 (17-34)

    Kind 4 (17-34) Item Description Default Instruction For 16-buttons doorphone only 23 Ringing group of 1 doorphone key Please refer to K2 item 46 0: Unlisted 1-99: Serial no 24 Sequential number of doorphone Application: If installed more than 1pc of doorphone.
  • Page 65: Kind 4 (35-52)

    Kind 4 (35-52) Item Description Default Instruction 0: No 1: Yes 35 Send warning tone of call waiting Application: To alert the on-line station there’s another incoming call waiting 0: No 36 Bill metering 1: Yes (send the simple running account) Only workable when install the RS-232 interface 00: Invalid 37 ARS Group...
  • Page 66: Kind 4 (53-72)

    Kind 4 (53-72) Item Description Default Instruction 00: Null 01-32 channel 53 Video channel of this line Application: Switch the channel of video controller when call incoming 0: CO to CO is prohibited 54 Duration for CO to CO call-forwarding 1-9999 seconds 00-99 groups Recording group of voice mail while on...
  • Page 67: Dss Program: Kind 5

    2.8 DSS PROGRAM: Kind 5 2.8.1 Connection Figure Station no. 25 Station no. 24 (DSS phone) (V005-L1) (V004-L0) physical locations of station lines Note: The master keyphone and DSS must be installed on the same station port- the master keyphone on L1 and 1 DSS on L0.
  • Page 68 System has reserved Installation position of 004 for 1 DSS console DSS ADR : 004 K000 : L Move cursor here and then press 2 switch to Station (shown code: L) after pressing HOLD DSS ADR : 004 L25 means station/extension no. 25 K000 : L25 K000 is for master keyphone Extension 25 is the master keyphone of this DSS console...
  • Page 69: To Change The Collocated Keyphone

    2.8.3 To change the collocated keyphone Application: Change a different extension to collocated with the DSS console. Notice: To modify the relatives program is necessary. or setting Kind 5 password Physical location HOLD of DSS key Original physical location of DSS console, please press HOLD twice DSS ADR : 004 when cursor is here K000 : L25...
  • Page 70: To Change The Flexible Function Number

    2.9.2 To change the flexible function number: Enable the user to change/program the frequent function code. Line Type : STA12T V001 P20 when cursor is here HOLD Line Type : STA? V001 P21 when cursor is here Line Type : STA? F000_ P201 The prefix code switch to F Input the function number and then HOLD...
  • Page 71: Call Restriction Program: Kind 7

    2.10 CALL RESTRICTION PROGRAM: Kind 7 To program the restricted dialing table to reject the incoming number or only accept the telephone number to dial-in. or setting Kind 7 HOLD password 0-5: Restricted dialing table (there are 30 sets number in each table.) Limit Table:0 6-8: Allowed dialing table (there are 30 sets number...
  • Page 72: Tone Source / Make Break Program: Kind 8

    2.11 Tone Source / Make Break PROGRAM: Kind 8 or setting HOLD Kind 8 password T-n:00 When cursor is here  press [HOLD] T-n:00 The item 00 application of the item see Appendix II (system tone source supply of physical location.) H: a-b (a: tone source of make break 1, b: tone source of make break 0) Make break 1: on / selection H: 240 channel Make break 0: off / selection –...
  • Page 73: Tone Source And Default

    2.11.4 Tone source and default Item Description Default Remark 240 – 223 1111111111111110 00 Internal dialing tone Internal dialing tone with setting "Do Not 240 – 223 1110011111111110 Disturb" 240 – 241 1111000011110000 02 Dialing tone for call transfer 03 Dialing tone of LCR/ARS 247–...
  • Page 74: Item: 33-56

    Item: 33-56 Item Description Default Remark 245 – 223 1111111110000000 33 Special line call ringing tone 245 – 223 1111100000000000 34 CO call transfer ringing tone 245 – 223 1111100000000000 35 Un-discriminating ringing tone 245 – 223 1111100000000000 36 Recall ringing tone Tone time 243 –...
  • Page 75: Tone Source Time Program: Kind 18

    2.12 TONE SOURCE TIME PROGRAM: Kind 18 or setting Kind HOLD password Item Time: HOLD number 000-999 2.12.1 Time unit is according to K1 item 28 to program. The initial value is 0.2 sec. 2.12.2 For item using, please refer to tone source name and default. 2.12.3 To change item, please adjust by [VOLUME] key.
  • Page 76: Account Code Program: Kind 11

    2.14 ACCOUNT CODE PROGRAM: Kind 11 Enable to program 400 sets 4/8 digits PIN code for account code feature. The preceding 4 digits can be printed by RS-232 simple running account. or setting Kind HOLD password Enter 4/8 digits of PIN code 0-99 sets: refer to the class of program K1 item 81.
  • Page 77: Caller-Id Display Status Program: Kind 14

    2.15 CALLER-ID DISPLAY STATUS PROGRAM: Kind 14 or setting Kind HOLD password Group: 00-19 sets L00: 00 Identify the number length (00 means do not check) C: The prefix digit which need to be amend (available CT:00L00C……… amended number can be up to 7 digits. +………...
  • Page 78: Lcr (Least Cost Route) Program

    2.16 LCR (Least Cost Route) PROGRAM Least Cost Route is a system programmable feature that automatically selects the least cost route available at the time an outside call is made; LCR had associated with ARS (Automatic Route Selection) in the system. 5 different programming kinds for LCR table: K21:LCR Parameter Set K22:LCR Prefix Code Table...
  • Page 79: Kind 22: Lcr Prefix Code Table

    Item Name Default Remark 05 ARS2 Hunting Mode Same as above 06 ARS3 Hunting Mode Same as above 07 ARS4 Hunting Mode Same as above 08 ARS5 Hunting Mode Same as above 09 ARS6 Hunting Mode Same as above 10 ARS7 Hunting Mode Same as above 11 ARS8 Hunting Mode Same as above...
  • Page 80: Kind 23: Lcr Time Table

    2.16.3 KIND 23: LCR Time Table Max. Table pointer range is 300 - 349 Check all carriers available time list for fee charged. The system can select the least expensive available route and carrier at certain time. This table can set least cost time of some holiday or special day if provided from carrier. And disable to check month day when you fill "00-00"...
  • Page 81: Kind 24: Lcr Adjust Code Table

    2.16.4 KIND 24: LCR Adjust Code Table Max. Table point range is 500 - 599 Max. Added prefix digits 20. Use the "LCR Adjust Code Table" program when it is necessary to delete some prefix digits and/or add digits from the user-dialed number. For example, if the user manually dial a Carrier Access Code but the carrier is not the least cost, modification is required.
  • Page 82 ARS Group Table 50 Item Pointer ARS/Group Remark If all line occupied in ARS001,search next P700 ARS001002003004 ARS002→003→004 Dial-out from ARS001, If all lines occupied in ARS001 P701 ARS001000000000 System will dial-out from normal CO line. If all line occupied in ARS009002003004, P702 ARS009002003004 System will indicate busy on screen of phone.
  • Page 83: Input The User's/Contact Name

    2.17 INPUT THE USER’S/CONTACT NAME Input by ASCII code. 1. Max. 8 characters 2. To input ***6 on keyphone (K 6 item 115), then key in the individual name 3. To input on program K27 and then key-in the name 2.17.1 Table of ASCII Code Key-in ASCII (Symbol Number English Alphabet) as following synopsis: Low 4-bit...
  • Page 84: Rs-232 Data Form And Command

    3. RS-232 DATA FORM AND COMMAND 3.1 OUTPUT OF SIMPLE RUNNING ACCOUNT 3.1.1 Description of RS-232 form Refer to K1 item 52 & 53 and K3 item 20, 25 & 74 0123456789 0123456789 0123456789 0123456789 0123456789 0123456789 0123456789 0123456789 The printing form of simple running account: $TO:10/08/01 20 21 01 88673740801 0000 08:15:33 00168 00000 Description of RS-232 form:...
  • Page 85: Check-In (Ci) Program

    3. NoAnser T06 7 Sec NoAnser: No Answer T06: the 6 trunk line 7 Sec: ringing 7 second No incoming telephone number (without installed the CID card or caller didn’t send the number) 4. L20Anser T06 7 Sec NoAnser: No Answer L20: extension 20 7 Sec: ringing 7 second No incoming telephone number (without installed the CID card or caller didn’t...
  • Page 86: Check-Out (Co) Program

    3.3 CHECK-OUT (CO) PROGRAM 3.3.1 Send "CO" command and station number to system. Send “CO” command and station number with ended by 0DH, 0AH. The command will send simultaneously to RS-232 while the attendant telephone orders the “CO” command. Eg.: “CO 20" 0DH, 0AH : The Check-out station is 20. 3.3.2 Description for system response A.
  • Page 87: Description For System Response

    3.4.2 Description for system response A. "OK SET ALARM", station No., time, 0DH, 0AH : the alarm setup is OK. B. "Over 60 minutes!", 07H, 07H, 0DH, 0AH : Minute error! Please enter 00-59 minutes. C. "Over 24 Hours!", 07H, 07H, 0DH, 0AH : Hour error! Please enter 00-23 hours. D.
  • Page 88: Glossary And Feature Program

    4.GLOSSARY AND FEATURE PROGRAM 4.1 Glossary Abbreviated Dialing Also named Speed dialing. Absence Message Enable to display the absence reason on the caller’s digital key telephone. Account Call Let different class of users use the same station to call out by their individual password. It also able to manage the call cost more effectively if collocated with SMDR/Billing system.
  • Page 89 Call Pick-up Enables users in a programmed call pick-up group (e.g. call center in the same group) to answer calls for each other or a user can pick up a call at any extension by dialing a feature code or feature button.
  • Page 90: Appendix

    5. Appendix 5.1 Appendix1: Incoming Directive Directive No. Application Remark F128 Built-in DISA (DSP) F168 CO/Station Common incoming directive F170 Doorphone Built-in VM/ External DISA F171 (ISDK2 –DISA/UDF2-DISA) F172 ISDN line Route to K26 (DDI) 5.2 Appendix2: List of Function number and operation code Function Operation Function...
  • Page 91: F064-F153

    F064-F153 Function Operation Function Operation Function Name Function Name Number Code Number Code F064 Night transfer *164 F065 F066 On-line point-out/teaching F067 F068 Morning call (DSS) F069 Display station DND status F070 F071 F072 F073 Alarm 2 F074 Alarm 3 F075 Alarm 4 F076 Alarm 5 F077 Alarm 6...
  • Page 92: F154-F171

    F154-F171 Function Operation Function Operation Function Name Function Name Number Code Number Code F154 F155 IP One-touch-dial/DSS Key *164 F156 IP Function number F157 IP Operation code Release the electric door lock (can’t F158 F159 use * or # key) F160 Speaker key F161 Page key F162 Transfer key...
  • Page 93: Appendix4 Physical Location, Line No And Programed No

    5.4 Appendix4 Physical Location, Line No and programed No. UD-60 Basic (F8001 MPU)
  • Page 94: Plus (F8013 Mpu)

    UD-60 Plus (F8013 MPU)

This manual is also suitable for:

Ud-60 plus

Table of Contents