A2O Pure Use and installation manual Control via app About A2O Pure Dimensions and weight List of included components Installation scheme How to install Operating instructions Replacement of filters Maintenance For the most updated installation manuals in more languages, go to Aquaporin.com/installation or...
Control via app Connect with your purifier Connect your A2O purifier with your smartphone to manage and track your water usage in real time. Receive updates Receive recommendations to make using your A2O purifier simpler and get reminders when it’s time to change filters. Track usage Get an overview of your water usage, monitor filter lifetime, see next maintenance,...
About A2O Pure The A2O Pure is a direct flow water purifier The Aquaporin Inside® Drinking Water with Aquaporin Inside® technology. The Membrane (DWRO®) uses unique “made by device can be used wherever traditional nature” proprietary membrane technology reverse osmosis (RO) devices or other types to remove PFAS, pesticides, heavy metals, of water devices reach their limits.
Page 6
Technical data Flow rate of filtered water 2.1 L/min Water recovery rate 65% (2:1) Membrane capacity 126 L/h Salt rejection > 90% Electrical connection 220–240V AC Power consumption (operation) 95 W Power plug standard Noise level 53 ±1 dB Wi-Fi connection + app Leak detector Membrane flushing (auto-cleaning) Feedwater, pure water and wastewater connection...
Page 7
Warranty and disclaimer This manual contains important instructions Observe: The information and for safe and efficient use of the A2O Pure. It instructions contained in the is part of the device and must be constantly manual have been compiled based available at the place of operation.
Page 8
Operating and safety notes Observe: Improper installation of the device may cause damage to it. Despite all possible precautionary measures, - Observe any country-specific installation some residual risk remains with any product, regulations (such as DIN 1988, EN 1717), especially if it is used improperly. Warranty general hygienic practices and technical claims are void unless the provisions in this data for protecting the drinking water.
Installation scheme Faucet The pressure reducer including check valve for backflow prevention Pure Drain Wastewater must be used. water pipe Inlet water (tap water) Water Inlet water Pure water source Wastewater...
How to install Before you start, thoroughly clean your hands and any tools you will use during installation. The installation will take approximately 1 hour. Before installation, ensure that the cold water Before installation, remove the grey IN and valve is turned off/closed. OUT plugs as well as the DRAIN plug.
Page 13
Drain installation Step 1 Step 2 Drill a ø 7 mm hole in the drainage Place the gasket in the drain clamp, so pipe under the sink. it will sit between the drain clamp and the drain pipe. Gasket Step 3 Step 4 Insert the 1/4″...
Page 14
Step 5 Cut the 1/4″ PE pipe to fit the installation and insert it into the wastewater connection on the A2O Pure. Lock the PE pipe in place with a green retaining ring. Wastewater...
Page 15
Inlet installation Step 1 Connect the valve to the cold water pipe. Cold water pipe Step 2 Step 3 Insert the 3/8″ PE pipe onto the valve. Lock the 3/8″ PE pipe with a blue retaining ring.
Page 16
Note the direction of the pressure reducer! The arrow should be pointing towards the A2O Pure (away from the inlet water ball valve). Step 5 Cut the length of the 3/8″ PE pipe to fit your installation.
Page 17
Faucet installation Step 1 Drill a ø 12 mm hole in your sink, adjacent to your regular faucet. Step 2 Step 3 Peel off the seal on Remove the rubber cover from the spacer (8B). the faucet. Assemble and tighten the faucet with your hands (do not use tools).
Page 18
Cut the length of the 1/4″ PE pipe to fit your in the other end of the push-in fitting. installation and insert it into the “pure water” connection on the A2O Pure. Lock the push-in fitting with a green retaining ring.
Page 19
Connecting power Step 1 Step 2 Turn on the water. Connect the A2O Pure to your power supply. WARNING: Check for leakages before proceeding. TURN...
Page 20
Aquaporin app The filter life indicators on the top panel will To get the most out of your A2O Pure flash and you will hear a sound. You should we recommend that you download the now hear water flowing into the A2O Pure.
Operating instructions User interface overview Water purification Wi-Fi Fault indicator light indicator indicator Rinse button Select/reset Pre-filter Post-filter DWRO® membrane life indicator life indicator life indicator...
Page 22
4 times. Once the light turns steady blue, the filter life has been reset. When the A2O Pure is connected to power, it - If there is no operation for 10 seconds will buzz, and the displays will be on after pressing the “Select”...
Page 23
Wi-Fi connection If water is dispensed while the device is in cleaning mode, the cleaning cycle will resume - To connect your A2O Pure to your smart when the faucet is closed. device, download the Aquaporin app. - Press and hold the “Clean” button until Cleaning after standby mode the Wi-Fi icon flashes.
Replacement of filters There are 3 filters inside the A2O Pure: The 3 filters remove particles, such as sand, dirt, and other sediments down to The pre-filter is a 2-in-1 filter that pretreats 5 microns, and it remove most drinking water...
Page 25
Step 1 Step 2 Close the ball valve. Unplug the power supply. TURN UNPLUG Step 3 Remove the cover and identify the filter that Take out the filter that you are replacing. needs to be replaced. Insert the new filter and tighten to the marked position.
Page 26
Step 4 Step 5 Once the filter has been changed, Plug in the power supply. open the ball valve. TURN Step 6 Step 7 The light on the top panel will flash. The Remember to flush the device before device will flush for 30 seconds and then consuming water! enter standby.
Recommended maintenance Disposal - Replace filter 1 and 2 at least every 12 months. Procedure: The A2O Pure device - Replace filter 3 approximately every consists of various materials 2 years. which need to be disposed of - Sanitize the unit upon commissioning properly.