- Inform DPI if you detect any malfunctions in the device components. Use only original DPI spare parts for servicing and repair. Note: EEBD Sekur Navy Cap 10 and Sekur Navy Cap 15 are designed only for escape from a hazardous atmosphere.
The SEKUR NAVY CAP range of equipment provides the user with escape breathing protection from contaminated or oxygen deprived environments in hazardous situations. Safety warning: the duration starts from the moment of activation of the air supply and not from the moment the hood is put on.
When components or assemblies are soaked in detergent or disinfectant solutions, they should be manually agitated. DPI does not recommend any type of mechanical, electrical or ultrasonic rinsing. Do not immerse the hood or valve in degreasing or disinfectant solutions.
Page 5
Disinfectant cod. No. 4437.0360 Do not exceed 30 °C. Rinsing and drying: remove residues of detergent and disinfectant solutions with plenty of clean running water, then wipe dry. When the components are dry, the temperature of 60 °C must not be exceeded 6.2.
Page 6
- Spray anti-fog liquid on the inner surface of the visor hood keeping it as far away as possible and spread it with a soft, clean cloth. Wipe the visor clean after a few minutes. DPI recommends the use of the following anti-fogging liquid: code 4200.2005...
Page 7
(10 minutes for Sekur Navy Cap 10 and 15 minutes for Sekur Navy Cap 15 respectively). If the duration is shorter or longer than indicated on the bag by more than 2 minutes, contact an authorised service centre.
Page 8
o Insert the straight part of the pin into the hole in the black marked face, as shown in figure 10 and figure 11, and push until the pin clicks into place. The positioning must adhere exactly to what is reported in Figure 11 to facilitate the activation of the air supply when the bag is opened.
Page 9
i) 3. Partially close the zip tie (fig. 24) and, when it is close enough, insert the free end of the plastic fastener into the hole in the inner flange of the zip tie. Then insert this free end of the clamp also through the ring of the "V"...
8. Transport and storage SEKUR NAVY CAP equipment, in both the 10 and 15 minute "ready to use" versions, should: - Be transported and stored in their original packaging when new and not yet used. - Be protected from dust and dirt, physical and mechanical damage and direct sunlight during transport and storage;...