CONTENTS 1 SAFETY PRECAUTIONS 2 ACCESSORIES 3 INSTALLATION SITE 4 INSTALLATION 4.1 Dimensions of the unit 4.2 Installation requirements Servicing space requirements Mounting the indoor unit 5 CONNECTING THE REFRIGERANT PIPING 6 CONNECTING THE WATER PIPING Connecting the space heating(cooling) water piping Connecting the domestic water piping Connecting the recirculation water piping Connecting the drainage hose to the indoor unit...
Page 4
9 TEST RUN AND FINAL CHECKS 9.1 Final checks 9.2 Test run operation (manually) 10 MAINTENANCE AND SERVICE TECHNICAL SPECIFICATIONS ERROR CODE ANNEX A...
1 SAFETY PRECAUTIONS DANGER WARNING CAUTION NOTE WARNING This appliance which connect 1-phase 6KW backup heater can be connected only to a supply with system impedance no more than 0.3079Ω. In case necessary, please consult your supply authority for system impedance information.
Page 6
Special requirements for R32 WARNING WARNING NOTE WARNING NOTE charged charged >...
Page 7
Use Table 2 in page5 to calculate the total minimum floor area (A mintotal required for the total refrigerant charge (m Use Table 3 in page5 and dm to calculate the minimum opening area (VA ,cm for natural ventilation between # A room and # B room ≥VA ≥VA...
Remove the wooden base Four one of them Four Fig. -4 Fig. - Fig. -5 WARNING Do not install the IDU near a bedroom; Suggest install it in a garage, utility room, corridor, basement, or laundry room; Be sure to adopt adequate measures to prevent the unit from being used as a shelter by small animals. Small animals making contact with electrical parts can cause malfunction, smoke or fire.
Select an installation site where the following conditions are satisfied and one that meets with your customer's approval. - Safe places which can bear the unit's weight and where the unit can be installed at an even level. - Places where there is no possibility of flammable gas or product leak. - The equipment is not intended for use in a potentially explosive atmosphere.
unit:mm NAME NAME Refrigerant gas connection 5/8"-14UNF Space heating (cooling) water inlet .R1" Refrigerant liquid connection 3/8" -14 UNF Space heating (cooling) water outlet .R1" Domestic hot water outlet R3/4‘’ Drainage Domestic hot water water Solar circulation outlet ( inlet (Plugged by the nut). Domestic cold water inlet Solar circulation inlet ( The content in the dotted...
﹤ Fig. -3 Fig. -4 5 CONNECTING THE REFRIGERANT PIPING l l a n i l c i f , t i please refer to "Installation and ower's manual (M-thermal split outdoor unit) Connecting the 16mm refrigerant pipe to the refrigerant gas connection. Additional tightening Outer Tightening...
CAUTION When flared joints are reused , the flare part should be re-fabricated. 6 CONNECTING THE WATER PIPING 6.1 Connecting the space heating(cooling) water piping To facilitate service and maintenance, two shut-off valves(field supply) and one overpressure bypass valve should be installed.
6.3 Connecting the recirculation water piping If domestic hot water recirculation function is requested,the recirculation pipe should be connected. 1.Removing the nut of the recirculation on the indoor unit. 2.Connecting the recirculation water pipe to the indoor unit. Fig.6-3 Fig.6-4...
6.4 Connecting the drainage hose to the indoor unit The water coming from the pressure relief valve and the condensate water is collected in the drain pan. The drain Connect the drainage pipe with a throat bander and insert the drainage pipe into the floor drain. Throat bander Floor drain Fig.
Page 19
flow switch should be removed and dried, then can be reinstalled in the unit. There need drying Fig. -7 NOTE 1.Counterclockwise rotation, remove the flow switch. 2.Dry the flow switch completely. CAUTION Be careful not to deform the unit’s piping by using excessive force when connecting the piping. Deforming the piping may lead to malfunction of heat pump.
Connect the water supply to the filling valve and open the valve. with water until the indicates a pressure of approximately 2.0 bar. air in the circuit as much as possible using the automatic air purge valves. least 2 full turns to release air from the system.
6.9 TYPICAL APPLICATIONS 6.9.1 Application1 .... FHL1 FHL2 FHLn One zone for floor heating loops 6.9.2 Application 2 FCU1 FCU2 FCUn .... FHL1 FHL2 FHLn One zone for floor heating loops and fan coil 6.9.3 Application 3 Double zone for floor heating loops and radiators...
Page 22
Code Assembly unit Code Assembly unit Outdoor unit Expansion vessel (Field supply) Indoor unit with tank P_o: Outside circulation pump (Field supply) User interface Filling valve (Field supply) Shut-off valve (Field supply) Bypass valve (Field supply) Filter (Accessory) P_s: solar pump (Field supply) Solar pannel pump (Field supply) Plate heat exchanger (Field supply) Solar pannel (Field supply)
7 FIELD WIRING WARNING A main switch or other means of disconnection, having a contact separation in all poles, must be incorporated in the fixed wiring in accordance with relevant local laws and regulations. Switch off the power supply before making any connections.
Fig. -1 Use the correct screwdriver to tighten the terminal screws. Small screwdrivers can damage the screw head and prevent appropriate tightening. Over-tightening the terminal screws can damage the screws. Attach a ground fault circuit interrupter and fuse to the power supply line. In wiring, make certain that prescribed wires are used, carry out complete connections, and fix the wires so that outside force cannot affect the terminals.
High voltage wire Low voltage wire Fig. 7.5 Connecting the main power supply Leakage Protection Switch must be installed to the Power Supply of the unit. L2 L3 optional optional L2 L3...
NOTE The ground fault circuit interrupter must be a high-speed type breaker of 30 mA (<0.1 s).Flexible cord must meet 60245IEC(H05VV-F) standards. 7.6 Connecting for other components Print Connect to Print Connect to Solar energy input Indicator light of unit signal operating status (field supply)
Page 28
The wiring of the thermostat should correspond to the CN24 CN21 CN28 settings of the user interface. Refer to ROOM CN16 CN32 CN13 THERMOSTAT. CN15 CN29 CN18 CN25 CN42 CN40 DIS1 CN31 CN41 CN22 CN35 CN36 be correct. CN17 26 27 15 16 18 19 20 23 24...
Page 31
7.6.12 For room thermostat: Room thermostat type 1(High voltage): "POWER IN" provide the working voltage to the RT, doesn’t provide the voltage to the RT connector directly. Port "15 L1" provide the 220V voltage to the RT 25 26 27 28 1 2 3 4 5 connector.
7.6.13 For solar energy input signal 25 26 27 28 1 2 3 4 5 29 30 31 32 6 7 8 9 10 CN30 CN11 CONNECT TO SOLAR KIT INPUT 220-240VAC Voltage 220-240VAC Maximum running current(A) Wiring size(mm 0.75 8 START-UP AND CONFIGURATION The unit should be configured by the installer to match the installation environment (outdoor climate, installed options, and user expertise.
DANGER Switch off the power supply before making any connections. After the installation of the unit, check the following before switching on the circuit breaker: Field wiring:Make sure that the field wiring between the local supply panel and unit and valves (when applicable), unit and room thermostat (when applicable), unit and domestic hot water tank, and unit and backup heater kit have been connected according to the instructions described in the chapter , according to the...
8.4 About FOR SERVICEMAN 8.4.1 DHW MODE SETTING "FOR SERVICEMAN" is designed for the installer to set DHW = domestic hot water the parameters. Go to > FOR SERVICEMAN> 1.DHW MODE SETTING. Press . The following pages will be Setting the composition of equipment. displayed: Setting the parameters.
Page 35
2 COOL MODE SETTING 8.4.5 TEMP. TYPE SETTING 2.1 COOL MODE 2.2 t_T4_FRESH_C 2.0HRS About TEMP. TYPE SETTING 2.3 T4CMAX 43°C The TEMP. TYPE SETTING is used for selecting whether 2.4 T4CMIN 20°C the water flow temperature or room temperature is used 2.5 dT1SC 5°C to control the ON/OFF of the heat pump.
Page 36
OTHER In this case, the setting value of zone 1 is T1S,the setting value of zone 2 is T1S2. The OTHER HEATING SOURCE is used to set the parameters of the backup heater, additional heating If you set DOUBLE ZONE and ROOM TEMP. to YES, sources .
Page 37
If YES is selected, the following pages will be displayed: 9 SERVICE CALL 11 TEST RUN PHONE NO. *************** MOBILE NO. ****************** 11.1 POINT CHECK 11.2 AIR PURGE 11.3 CIRCULATED PUMP RUNNING 11.4 COOL MODE RUNNING CONFIRM ADJUST 11.5 HEAT MODE RUNNING ENTER on the user is the phone...
Page 38
During HEAT MODE test running , the default target outlet When in air purge mode, SV1 will open, SV2 will close. water temperature is 35°C. The IBH (internal backup 60s later the pump in the unit (PUMPI) will operate for heater) will turn on after the compressor runs for 10 min.
Page 39
12.1 PREHEATING FOR FLOOR 12 SPECIAL FUNCTION Do you want to turn off the preheating Active the settings and active the for floor function? “SPECIAL FUNCTION”? CONFIRM CONFIRM 12 SPECIAL FUNCTION to scroll the cursor to YES and press , the preheating for floor will turn off.
During floor drying, all the buttons except are invalid. When the heat pump malfunctions, the floor drying mode will turn off when the backup heater and additional heating source is unavailable. If you want to turn off floor drying up, please press .
Page 41
8.4.16 SETTING PARAMETERS The parameters related to this chapter are shown in the table below. Setting Order number Code State Default Minumum Maximum Unit interval DHW MODE Enable or disable the DHW mode:0=NON,1=YES DISINFECT Enable or disable the disinfect mode:0=NON,1=YES DHW PRIORITY Enable or disable the DHW priority mode:0=NON,1=YES PUMP_D...
Page 42
HEAT MODE Enable or disable the heating mode The refresh time of climate related curves for heating t_T4_FRESH_H hours mode The maximum ambient operating temperature for heating T4HMAX ℃ mode The minimum ambient operating temperature for heating T4HMIN ℃ mode dT1SH The temperature difference for starting the unit (T1) ℃...
Page 43
12.4 t_DRYUP The day for w arming up during floor drying up The continue days in high temperature during floor 12.5 t_HIGHPEAK drying up The day of dropping temperature during floor drying 12.6 t_DRYD The target peak temperature of w ater flow during 12.7 T_DRYPEAK °C...
10 MAINTENANCE AND SERVICE 9 TEST RUN AND FINAL CHECKS In order to ensure optima l availabilit y of the unit, a number of checks and inspection s on the unit and the field wiring The installer is obliged to verify correct operation of unit have to be carried out at regular intervals.
11 TECHNICAL SPECIFICATIONS unit ower suppl input er to the technical capa sions 730*1920*730 730*2180*730 late heat changer changer lectric heater ernal water water pressure ilter water low low switc ower input panssion essel operating pressure pressure eight t weight 140kg 157kg 159kg...
12 ERROR CODES When a safety device is activated, an error code will be displayed on the user interface. A list of all errors and corrective actions can be found in the table below. Reset the safety by turning the unit OFF and back ON. In case this procedure for resetting the safety is not successful, contact your local dealer.
Page 48
ERROR MALFUNCTION FAILURE CAUSE CODE OR PROTECTION AND CORRECTIVE ACTION 1. The EEprom parameter is error, rewrite the EEprom data. 2. EEprom chip part is broken, change a new EEprom chip Indoor unit EEprom failure part. 3. main control board of indoor unit is broken, change a new PCB.
Page 49
ERROR MALFUNCTION FAILURE CAUSE CODE OR PROTECTION AND CORRECTIVE ACTION Three times “PP” The same to "PP". protection and Tw_out< 7℃ 1.Check the resistance of the sensor. 2.The Tbt1 sensor connector is loosen,reconnect it. Buffer tank up 3.The Tbt1 sensor connector is wet or there is water in,remove temp.sensor(Tbt1) fault the water ,make the connector dry.Add waterproof adhesive.
ANNEX A: Refrigerant cycle CD E Water side Refrigerant side ⑤ ④ ⑦ ⑩ ⑥ ③ ② ① ⑨ ⑧ HEATING COOLING B CD E Water side Refrigerant side ⑤ ④ ⑦ ⑩ ⑥ ③ ② ① ⑨ ⑧ HEATING COOLING Optional Unit Item...