NLTroubleshooting
Malfunction
E:32-00 lights up alternately
selend or indication
for water supply
burns.
E:34-00 lights up alternately
selend.
E:61-02 lights up alternately
selend.
46
Cause and Troubleshooting
Remove the strainer from the inlet hose
5.
Clean the strainer.
6.
Place the strainer in the inlet hose.
7.
Screw the water connection.
8.
Check the water connection for leaks.
9.
Put the plug back in the socket.
10.
Turn on the device.
11.
Water flows continuously into the appliance.
Close the tap.
1.
Contact the service department
2.
→ Page 54 .
No device error. Water drain pump is blocked or cover
of water drain pump is loose.
Clean the drain pump.
1.
→ "Clean the drain pump", page 52
Tighten the drain pump cover securely.
2.
→ "Clean the drain pump", page 52
Remark:This is not a fault of the device. The device has
detected a problem with pumping down. The problem
can most likely be corrected by the user or the installer.
We point out that errors by the user or by
tallation are not covered by the warranty and
the ins
will be brought.