Download Print this page

Ace PWM400 Quick Start Manual

1q pwm chassis adjustable speed drive for pmdc brushed motors

Advertisement

Quick Links

Specifications
Line
Armature
Voltage
Voltage Range
Model
(VAC)
(VDC)
Current (Amps)
115
0 - 130
PWM400-2
230
0 - 240
115
0 - 130
PWM400-5
230
0 - 240
115
0 - 130
PWM400-10
230
0 - 240
* Heat sink kit HSK- 0001 must be used when the continuous output current is over 5 amps.
10 amps up to 25°C ambient. Derate to 7 amps when over 25°C ambient.
AC Line Voltage
......................................................115/230 VAC ± 10%, 50/60 Hz, single phase
Form Factor
..........................................................................................................................1.05
Acceleration Time Range
....................................................................................0.5 - 6 seconds
Deceleration Time Range
....................................................................coast to stop - 6 seconds
Analog Input Voltage Range (Signal must be isolated; S1 to S2)
Input Impedance (S1 to S2)
.........................................................................................70K ohms
Load Regulation
...................................................................................1% base speed or better
Speed Range
......................................................................................................................100:1
Vibration (0 - 50 Hz)
............................................................................................0.5G maximum
(>50 Hz)
...............................................................................................0.1G maximum
Ambient Temperature Range
...................................................................................10°C - 40°C
Weight
..............................................................................................................................0.8 lbs
Safety Certifications..........................................
UL/cUL Recognized Equipment, file # E132235
Safety
Certifications..................................................
CSA Certified Component, file # LR41380
Installation
Mounting
• Drive components are sensitive to electrostatic discharge. Avoid direct contact with the circuit
board. Hold the drive by the chassis or heat sink only.
• Protect the drive from dirt, moisture, and accidental contact.
• Provide sufficient room for access to the terminal block and calibration trim pots.
• Mount the drive away from heat sources. Operate the drive within the specified ambient operating
temperature range.
• Prevent loose connections by avoiding excessive vibration of the drive.
• Mount the drive with its board in either a horizontal or vertical plane. Eight 0.19" (5 mm) wide slots
in the chassis accept #8 pan head screws. Fasten either the large base or the narrow flange of the
chassis to the subplate.
• The chassis should be earth grounded. Use a star washer beneath the head of at least one of the
mounting screws to penetrate the anodized chassis surface and to reach bare metal.
Heat Sinking
The PWM400-10 requires an additional heat sink when the continuous armature current is above 5
amps. Use ACE heat sink kit part number HSK-0001. Use a thermally conductive heat sink compound
(such as Dow Corning 340® Heat Sink Compound) between the chassis and the heat sink surface for
optimal heat transfer.
Wiring
Use 18 - 24 AWG wire for logic wiring. Use 14 - 16 AWG wire for AC line and motor wiring.
Shielding Guidelines
As a general rule, ACE recommends shielding of all conductors. If it is not practical to shield power
conductors, ACE recommends shielding all logic-level leads. If shielding of logic-level leads is not
practical, the user should twist all logic leads with themselves to minimize induced noise. It may be
necessary to earth ground the shielded cable. If noise is produced by devices other than the drive,
ground the shield at the drive end. If noise is generated by the drive, ground the shield at the end
away from the drive. Do not ground both ends of the shield.
Fusing
ACE drives require an external line fuse for protection. Use fast acting fuses rated for 250 VAC or
higher and 150% of the maximum armature current. Fuse the HOT leg of the AC line when using 115
VAC and both lines when using 230 VAC.
PWM400
1Q PWM Chassis Adjustable Speed Drive
for PMDC Brushed Motors
Continuous
• DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED. Have a
qualified electrical technician install, adjust and service this equipment. Follow the National
Armature
Horsepower
Electrical Code and all other applicable electrical and safety codes, including the provisions of the
Range
Occupational Safety and Health Act (OSHA), when installing equipment.
1/20 - 1/6
2.0
• Circuit potentials are at 115 or 230 VAC above earth ground. Avoid direct contact with the printed
1/10 - 1/3
circuit board or with circuit elements to prevent the risk of serious injury or fatality. Use a non-
1/6 - 1/2
metallic screwdriver for adjusting the calibration trim pots. Use approved personal protection
5.0
1/3 - 1
equipment and insulated tools if working on this drive with power applied.
1/2 - 1
• Reduce the chance of an electrical fire, shock, or explosion by using proper grounding techniques,
10.0*
over-current protection, thermal protection, and enclosure. Follow sound maintenance procedures.
1
- 2
• ACE strongly recommends the installation of a master power switch in the line voltage input. The
switch contacts should be rated for 250 VAC and 200% of motor nameplate current.
• Do not disconnect any of the motor leads from the drive unless power is removed or the drive is
disabled. Opening any one lead while the drive is running may destroy the drive.
• Under no circumstances should power and logic level wires be bundled together.
• Be sure potentiometer tabs do no make contact with the potentiometer's body. Grounding the
input will cause damage to the drive.
.................................0 - 5 VDC
Line Input
Connect the AC line power leads to terminals L1 and L2. ACE recommends the use of a double-pole,
single-throw master power switch. The switch should be rated at a minimum of 250 VAC and 200% of motor
current.
Motor
Connect the DC armature leads to terminals A1 and A2. If the motor does not spin in the desired direction,
power down the drive and reverse these connections.
Speed Potentiometer
Use a 10K ohm, 1/4 W potentiometer for speed control. Connect the counter-clockwise end of the
potentiometer to S1, the wiper to S2, and the clockwise end to S3. If the potentiometer works inversely of
desired functionality, (i.e. to increase motor speed, you must turn the potentiometer counterclockwise),
power off the drive and swap the S1 and S3 connections.
Inhibit
Short the INHIBIT terminals to coast the motor to zero speed. Open the INHIBIT terminals to
accelerate the motor to set speed. Twist inhibit wires and seperate them from power-carrying wires or
sources of electrical noise. Use shielded cable if the inhibit wires are longer than 18 inches (46 cm). If
shielded cable is used, ground only one end of the shield to earth ground. Do not ground both ends of
the shield. Do not use the inhibit for emergency stopping.
ACE offers two accessory plug harnesses for connecting to the inhibit terminals; part number KTW-0001
[18 in (46 cm) leads] and part number KTW-0002 [36 in (91 cm) leads].
Safety Warnings
Connections
POWER
LOGIC
14300 De La Tour Drive
South Beloit, IL 61080
Phone: (815) 624-6915
Fax: (815) 624-6965
www.americancontrolelectronics.com
Full manuals available online or use QR code
Dimensions
0.19 [5 ]
C505
S3
C503
C504
C502
S2
S1
3.64 [92]
IL50 2
CURRENT
LIMIT
TH50 1
POWE R
IL50 1
CURRENT LIMI T
ACCE L
MAX SPD MIN SP D
IR COM P
DECE L
3.80 [97]
4.30 [109 ]
0.82 [21]
A
2.10 [53]
0.96 [24]
MODEL
DIMENSION "A" HEIGHT
PWM400-2
2.50 [62]
PWM400-5
3.20 [81]
PWM400-10
3.90 [99]
ALL DIMENSIONS IN INCHES [MILLIMETERS]
CW
C505
S3
C503
C504
C502
S2
S1
10K OH M
SPEED A DJUS T
IL50 2
CURRENT
POTENTIOMETER
LIMIT
TH50 1
IL50 1
POWE R
CURRENT LIMI T
DECE L
ACCE L
MAX SPD MIN SP D
IR COM P
Inhibit
Terminals
* NOTE: Do not add fuse to L2
unless input voltage is 230 VAC.
D
1.75 [44]
0.70 [18]
0.19 [5 ]
MOTO R
*FUS E
D
FUSE
ST OP
SWITCH
AC LINE
VOLT AG E
120/240 VA C

Advertisement

loading

Summary of Contents for Ace PWM400

  • Page 1 • board. Hold the drive by the chassis or heat sink only. Connect the AC line power leads to terminals L1 and L2. ACE recommends the use of a double-pole, • Protect the drive from dirt, moisture, and accidental contact.
  • Page 2 Startup Operation Calibration STARTUP DECELERATING & STOPPING Minimum Speed (MIN SPD): The MIN SPD setting determines the minimum motor speed when the Decelerate to Minimum Speed speed adjust potentiometer is set for minimum speed. It is factory set for zero speed. To calibrate the - Verify that no foreign conductive material is present on the printed circuit board.

This manual is also suitable for:

Pwm400-2Pwm400-5Pwm400-10