Summary of Contents for Chr. Hansen MilkSafe Fast

  • Page 1 MilkSafe™ Desktop Reader Connect User Manual Page 1 of 15...
  • Page 2: Table Of Contents

    Contents Introduction ..........................3 Intended Use ........................... 3 Materials Included ........................3 Warranty ............................. 3 Main features of the app ......................3 Run Test........................... 3 Test Records ..........................3 Settings............................ 3 Safety Precautions ........................4 Operating location ........................4 Ambient conditions........................4 Power Supply...........................
  • Page 3: Introduction

    The warranty does not cover removable parts (such as cartridges for the test strips) or consumables. The battery included is not covered by the warranty and Chr. Hansen does not carry any responsibility of use.
  • Page 4: Safety Precautions

    screen brightness, connect to Milksafe™ Cloud, LIMS & PLC integration, incubation and calibration verficiation, and software update. Safety Precautions Operating location The location of the Milksafe™ Desktop Reader Connect should be on a desk or on a stable and level surface with enough surrounding space to easily insert the test strip/test cassette or to unplug the Reader.
  • Page 5: Getting Started

    8. If the Reader should be connected to Milksafe™ Cloud, please login with the username and password provided by your administrator (or Chr. Hansen representative). The Reader will hereafter automatically synchronize with the account settings determined in the Milksafe™ Cloud.
  • Page 6: Setting Up The Reader (Advanced Functionalities)

    The scanner may be used to scan the QR code on the Milksafe™ FAST tests. To activate this functionality see under advanced functionalities. Furthermore, the scanner may also be used to scan QR or barcodes during the test flow to record test related information and operator identification. How to use the scanner 1.
  • Page 7: Connectivity And Data Transfer

    Go into Settings on the home screen (password “CH123456”) › Select Milksafe™ Cloud and enable login with the username and password privded by the administrator or Chr. Hansen representative. › The test records on the Reader and any future test results will hereafter be automatically exported to the cloud from where test records can be exported.
  • Page 8: Reader Operation

    Updating the Reader software It is recommend to keep the device updated with the newest software to enable new features, test types etc. The software can be found on Milksafe ™ Downloads, or downloaded automatically from Milksafe™ Cloud if the Reader is connected to the internet. ›...
  • Page 9: Incubating And Reading Cassette Tests (Milksafe™ Fast)

    QR code in this sequence) 7. Insert the test strip into the supplied standard carridge and fully insert the cartridge into the reader housing. Press Start Test, or for Milksafe FAST insert the cassette in the Reader and press Read only 8.
  • Page 10 7. Pipette the milk into the cassette and insert fully the cassette into the Reader housing. Press Incubate and Read 8. The incubation will start automatically and after the defined incubation time the Reader will automativally interpret the test result and show the Result screen after a few seconds. 9.
  • Page 11: Performing A Confirmation Flow

    Performing a confirmation flow A confirmation flow will be initiated on the Reader when the test result is positive or weak-positive (ratio <1.1). Please see below flow chart for illustration: 1. The confirmation flow will be actiaved upon the 1 positive result.
  • Page 12: Test Records And Export Data

    Test Records and Export data › To view previous test results, select Test Records on the home screen of the Reader. The Reader has a storage capacity of approx. 100,000 test results. › To navigate up and down use the Page up and Page Down buttons. ›...
  • Page 13: Maintenance Notes

    3. Select the standard test corresponding to the regular test performed on the reader e.g., for Milksafe FAST 3BTC, please select the standard test cassette with 5 lines and press Start test 4. Upon completion of the verification test, the Reader will deplay the results for temperature and reader verification on the final result screen.
  • Page 14: Service And Repairs

    For all service or repair needed beyond the regular verification protocol, exchange of external devices e.g., hand-held scanner etc., please contact your local Chr. Hansen representative for assistance. Attempts to open or repair the Reader by non-authorized personnel will void the warranty.
  • Page 15 Experts for the dairy industry Chr. Hansen believes in improving the quality of food and health. We believe the best results are achieved when working closely with you. Our experienced application and industry specialists provide you with the knowledge, inspiration, support, and customized solutions you need to be successful.