READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.
Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit
or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.
1.
Installation and servicing of UV units or systems (in an
air conditioning system or not) can be hazardous. Only
trained and qualified service personnel should install,
repair or service equipment.
2.
Untrained personnel can perform basic maintenance
functions such as replacing lamp(s) and/or filter(s). All
other operations should be performed by trained service
personnel.
3.
The unit is not to be used by persons (including children)
with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge.
CAUTION: Unit is not a toy. Keep away from
unsupervised children. Do not leave children unattended
with the unit.
4.
DO NOT hang onto the UV unit or system.
5.
Some UV units or systems could be heavy: Make sure
you have a minimum of 2 people to safely move or install
these UV units or systems, and make sure you adopt the
most ergonomic position possible (use UV unit or system
handles, if applicable).
CAUTION: Installing or maintaining heavy equipment,
especially overhead, can cause back pain or other injuries.
6.
When installing or servicing an overhead UV unit or system,
be careful not to fall off the stepladder. Furthermore, make
sure the UV unit or system latches are always in place to
prevent falling parts.
CAUTION: Some parts of some UV units and systems
may open suddenly if the UV unit or system is installed
high up without its locks.
7.
Units that are obviously damaged must not be operated.
Installation Date: _______________
Installer Contact Info.: _________________________________________
SANUVAIR
Commercial Model

IMPORTANT SAFETY INSTRUCTIONS

NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP.
8.
CAUTION: When working on the UV unit or system,
observe precautions on the literature, tags and labels
attached to the UV unit or system, and all other safety
precautions considered as best practices in the HVAC
industry, if applicable.
9.
When applicable, local regulation may comprise more
restrictive installation and/or certification requirements.
The aforementioned requirements prevail on those of this
document and the installer agree to conform to these at his
own expense.
10. Follow all the safety instructions outlined in this document
and respect all local and national codes applicable.
11. All UV units or systems contain a UV-C source. Damage to
the housing or unintended use of the UV unit or system may
result in harmful UV-C leaks. UV-C may, even in little doses,
cause harm to the eyes and skin.
12. Never expose eyes or skin to an operating UV lamp.
Therefore, before installing or performing maintenance
on the UV unit or system, TURN OFF AND DISCONNECT
the UV unit or system from all power sources (there
may be more than one switch to disconnect) and also
disconnect the HVAC system, is applicable.
CAUTION: Electrical shock may cause injuries or
possibly death. FIRST AID INSTRUCTIONS: If injured,
consult a doctor.
13. UV rays may damage certain types of filters (polymer or
plastic); please keep the UV unit or system light away from
shining directly on plastic.
Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.1
S600
®
14. When installing or performing maintenance on the UV unit
or system, it is recommended to wear safety gloves. In
order to avoid reduced performance of lamp(s), do not
touch lamp glass without gloves.
15. Just like conventional fluorescent lamps, UV lamps contain
a small quantity of mercury: if a lamp breaks, clean and
dispose of with care. UV lamps can be disposed/recycled
after use in the same way as any other fluorescent lamps.
Contact and follow the specific instructions of your local
and national authorities.
15.1. Dispose of unit or system according to the specific
instructions and standards of your local and national
authorities.
16. Use only specified SANUVOX branded replacement
UV lamps for your UV unit or system. Use of any other
lamps will void your warranty and can result in damage to
the UV unit or system.
17. Sanuvox UV units or systems are not waterproof. DO NOT
INSTALL OUTDOORS OR IN WET LOCATION unless
specified otherwise.
18. Use of this unit or system supplements, but does not
replace, infection control best practices. Users must follow
all these practices, particularly with regard to cleaning and
disinfecting surfaces.
For any inquiries on a UV unit or system, contact :
Installed by: _________________
Instruction Manual
SAVE THESE INSTRUCTIONS
Robert Smith
146 Barr St, Saint-Laurent
Quebec, CA, H4T 1Y4
1-888-726-8869
techsupport@sanuvox.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SANUVAIR S600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sanuvox SANUVAIR S600

  • Page 1: Important Safety Instructions

    146 Barr St, Saint-Laurent Units that are obviously damaged must not be operated. Quebec, CA, H4T 1Y4 1-888-726-8869 techsupport@sanuvox.com Installation Date: _______________ Installed by: _________________ Installer Contact Info.: _________________________________________ Sanuvox Technologies Inc, © 2020 All rights reserved. September 2023 EN v.1...
  • Page 2: Table Of Contents

    Step by Step Lamp Replacement How to Clean your Product Step by Step Inlet Filter Cleaning STORAGE ULTRAVIOLETS ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE TROUBLESHOOTING Problems & Solutions Table A. Step by Step Lamp Test WARRANTY CUSTOMER SERVICE www.sanuvox.com 1-888-726-8869...
  • Page 3: About The Product

    ® room. Compact and efficient, the Sanuvair S600 can be installed in less than 30 minutes. ® For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869. COMPONENTS How it Works The Sanuvair S600 is comprised of a ventilator, fan speed control, a mesh filter, three UV lamps and the cabinet enclosure. The ®...
  • Page 4: Setup & Installation

    CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869. What’s included The SANUVAIR S600, a mesh filter, three (3) UV lamps and a basic installation kit.
  • Page 5 Once the lamp is firmly into position, release the clamp that will hold the lamp in place. Proceed the same with the two other lamps. Your new SANUVAIR S600 ® is now ready to operate! www.sanuvox.com 1-888-726-8869...
  • Page 6: Operation

    S600 is quick and easy. Simply turn off the power source, open the lamp access door, remove ® and dispose of the old lamps, replace them with new Sanuvox branded UV lamps, close the access door and turn the power source back on. See below for detailed step by step instructions.
  • Page 7: How To Clean Your Product

    Once a year or as needed, clean the interior of the unit (wall and motor plate), with mild non-abrasive soap. It is recommended to use products that are environmentally friendly. CAUTION: Under no circumstance should water be sprayed or splashed onto the product. www.sanuvox.com 1-888-726-8869...
  • Page 8: Step By Step Inlet Filter Cleaning

    (DNA/RNA) of microorganisms, which inactivates them. Unlike conventional UV lamps on the market, Sanuvox units and systems use a patented process that delivers a maximum dose of UV to the moving air stream or surfaces. CAUTION: Never expose eyes or skin to an operating UV lamp.
  • Page 9: Troubleshooting

    This indicates that the filament is good. Check the other two pins. If both sets of filaments test OK, the lamp is functioning. If one or both sets of filaments read an open circuit (infinity) on resistance, the lamp is defective. www.sanuvox.com 1-888-726-8869...
  • Page 10: Warranty