  • Page 1 Smart Radiator Thermostat Featuring LoRaWAN ® WT101 User Guide...
  • Page 2 The device must not be disassembled or remodeled in any way.  The device is not intended to be used as a reference sensor, and Milesight will not should  responsibility for any damage which may result from inaccurate readings.
  • Page 3 Revision History Date Doc Version Description Sept. 15, 2023 V 1.0 Initial version...
  • Page 4: Table Of Contents

    Contents 1. Product Introduction ......................... 5 1.1 Overview ...........................5 1.2 Key Features ..........................5 2. Hardware Introduction ........................5 2.1 Packing List ..........................5 2.2 Hardware Overview ......................... 6 2.3 Button and LED Patterns ......................7 2.4 Dimensions (mm) ........................7 3. Power Supply ............................. 7 4.
  • Page 5: Product Introduction

    With 1 pre-set date period and up to 16 customized heating plans, it enables the smart management of heating system and save unnecessary cost in a way. WT101 is a smart and highly environment-sensitive products, abnormal temperature difference and extreme-low temperature can quickly trigger it and it will take fast steps in correcting them by adjusting the valve opening.
  • Page 6: Hardware Overview

    1 × Theft-deterring 1 × Quick Start 1 × Collar Kit Guide Warranty Card Valve Adapter (Optional) Danfoss RA Danfoss RAVL Danfoss RAV M28 (Comap, Herz, Giacomini If any of the above items are missing or damaged, please contact your sales representative. 2.2 Hardware Overview The motor is used to push the radiator values to open or close as required.
  • Page 7: Button And Led Patterns

    2.3 Button and LED Patterns Function Action LED Display Quick press the reset button once or Light On: Device is on. Check On/Off Status rotate the control knob. Light Off: Device is off. Press and hold the reset button for more Reboot Blink slowly than 3 seconds.
  • Page 8: Installation Instruction

    3. Install the two batteries with correct direction, which is shown on the battery cover. 4. Restore the battery cover in place. After installing the batteries, the device will turn on automatically and the LED display will light on for 3s. Note: 1) The device can be powered by 1.5V AA Li-FeS or alkaline batteries, not Li-SoCl...
  • Page 9: Thermostat Installation

    Danfoss RA Danfoss RAVL Danfoss RAV Giacomini Comap Herz 4.2 Thermostat Installation 1. Place the base plate on the valve or valve adapter and screw it tightly. The groove on the base plate should be faced to the direction of display. 2.
  • Page 10: Operation Guide

    5. Operation Guide 5.1 NFC Configuration WT101 can be monitored and configured via NFC. Please refer to the following configuration steps. 1. Download and install the Milesight ToolBox App from Google Play or Apple App Store. 2. Enable NFC on the smartphone and launch Milesight ToolBox.
  • Page 11: Lorawan ® Settings

    5.2 LoRaWAN Settings ® Configure AppEUI, Join Type, Application Key, and other basic LoRaWAN ® information. You can also keep all settings by default. Parameters Description Device EUI Unique ID of the device which can also be found on the label. App EUI The default App EUI is 24E124C0002A0001.
  • Page 12: General Settings

    1) Please contact sales for device EUI list if there are many units. 2) Please contact sales if you need random App keys before purchase. 3) Select OTAA mode if you use Milesight IoT cloud to manage devices. 4) Only OTAA mode supports rejoin mode.
  • Page 13 Parameters Description The interval of reporting battery level, temperature, motor status to Reporting Interval network server. Default : 1 0 min, Range: 1 - 1440 min Set the unit of temperature displayed on the LED display and Temperature Unit configuration page. Set the LED display direction to suit thermostat mounting orientation.
  • Page 14 Parameters Description Set target environment temperature. The device will adjust the valve Target Temperature every 10 minutes if the gap between target temperature and current temperature is more than tolerance value. Target Temperature Set the tolerance value between target temperature and current Tolerance temperature.
  • Page 15: Advanced Settings

    5.4.2 Heat Schedule WT101 supports to set at most 16 heat schedules within 1 pre-set date period. 1. Sync the device time via ToolBox App. Besides, the device can also ask for the time from...
  • Page 16 2. Set a heating date period, and the reporting interval except the heating date period. Temperature control will stop during non-heating period. 3. Set time-based control events and these events only execute within the heating date period. If the repeat day is not selected, this event will only execute once.
  • Page 17: Maintenance

    4. Click Save Schedule to export above settings as a schedule file. Click Select Schedule to import the schedule file to another device. 5.5 Maintenance 5.5.1 Backup WT101 supports backup templates for easy and quick configuring devices in bulk. The backup...
  • Page 18 feature is only for devices with the same model and LoRaWAN frequency band. ® 1. Go to Template page on the App and save the current settings as a template. The saved templates are also editable. 2. Select one saved template and click Write, then attach the smartphone to another device via NFC to reuse the template.
  • Page 19: Upgrade

    2) Only the Android version of ToolBox supports the upgrade feature. 5.5.3 Reset to Factory Default WT101 supports two methods to reset the device which are as following: Via Hardware: Press and hold the reset button for more than 10s until the LED display blinks quickly.
  • Page 20: Device Payload

    1 Byte 1 Byte M Bytes 1 Byte For decoder examples please find the files on https://github.com/Milesight-IoT/SensorDecoders. 6.1 Basic Information WT101 reports basic information whenever joining the network. Channel Type Description 0b (Power On) Device is on 01(Protocol Version) 01=>V1...
  • Page 21: Sensor Data

    Example: ff0bff ff0101 ff166791d19604050005 ff090100 ff0a0101 ff0f00 Channel Type Value Channel Type Value (Power On) (Reserved) (Protocol Version) (V1) Channel Type Value Channel Type Value 6791d19604050 0100 (Device SN) (Hardware Version) (V1.0) Channel Type Value Channel Type Value 0101 (Software (V1.1) (Device Type) (Class A)
  • Page 22 Examples: 1. Automatic Temperature Control periodic packet: report as reporting interval (10 minutes by default). 017564 0467e600 03670701 0b903a02 09903a02 Channel Type Value Channel Type Value Temp: 07 01=>01 64=>100% 07=263*0.1=26.3°C Channel Type Value Channel Type Value Target Temp: e6 Motor Stroke: 3a 00=>00 e6=230 02=>02 3a=570...
  • Page 23: Downlink Commands

    Type Value Channel Type Value 01=uninstalled 03=Calibration cleared 6.3 Downlink Commands WT101 supports downlink commands to configure the device. The application port is 85 by default. Channel Type Description 10 (Reboot) 17 (Time Zone) 2 Bytes, UTC timezone * 10...
  • Page 24 unit: min 57 (Release Open Window Status) b4 (Valve Opening Percentage) 1 Byte, unit: % 3 Bytes, b0 (Freeze Protection) Byte 1: 00-disable, 01-enable Byte 2-3: threshold temperature*10, unit: °C 25 (Child Lock) 00-disable, 01-enable Examples: 1. Reboot the device. ff10ff Channel Type...
  • Page 25 ffaf011e 3c00 Channel Type Value 01=enable af (Open Window Cooling rate: 1e=30*0.1=3 °C/min Detection) Stop control time: 3c00=>00 3c=60 minutes 7. Set valve opening percentage. ffb432 Channel Type Value b4 (Valve Opening Percentage) 32=>50% 8. Set freeze protection. ffb0011e00 Channel Type Value 01=enable...