Do you have a question about the RG10N2 (D2S) and is the answer not in the manual?
Questions and answers
Summary of Contents for Vivax RG10N2 (D2S)
Page 1
VIVAX CONTENT Remote controller Specifications ……….……………………………………...2 Function buttons ………………………………………………………………….. 2 Handling the remote controller …….……………………………………..…..4 Remote LCD screen indicators …………..…………………………………..5 How to use the basic functions ………..……………………………………...6 How to use the advanced functions ………..……………………………13 NOTES: The design and specifications are subject to change without prior notice for product improvement.
Page 2
VIVAX REMOTE CONTROLLER SPECIFICATIONS Model RG10N2 (D2S)/BGEF RG10N2 (D2S)/BGEFU1 Rated voltage 3.0V (Dry batteries R03/LR03X 2) Signal Receiving Range Environment -5°C 60°C NOTE: • Buttons design is based on typical model and might be slightly different from the actual one you purchased, the actual shape shall prevail.
Page 3
VIVAX FUNCTION BUTTONS Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use the Basic/Advance Functions section of this manual.
Page 4
Buttons and Functions Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.
Page 5
VIVAX Remote screen Indicators Information is displayed when remote controllers i powered up Breeze Away display (some units) Active clean feature display Fresh feature display Sleep mode display Transmission Follow me feature display Lights up when remote Wireless control feature display (some units)
Page 6
VIVAX HOW TO USE THE BASIC FUNCTIONS SETTING TEMPERATURE The operating temperature range for units is 16-30 C/60-86 F.You can increase or decrease the set temperature in 0.5 increments. AUTO operation In AUTO mode, the unit will automatically select the COOL, FAN, HEAT or DRY mode based on the set temperature.
Page 7
VIVAX HOW TO USE THE BASIC FUNCTIONS DRY OPERATION (DEHUMIDIFYING) 1. Press the MODE button to select DRY mode. 2. Set your desired temperature using the Temp + or Temp — button. 3. Press the ON/OFF button to start the unit.
Page 8
VIVAX HOW TO USE THE BASIC FUNCTIONS HEAT OPERATION 1. Press the MODE button to select HEAT mode. 2. Set your desired temperature using the Temp + or Temp — button. 3. Press the FAN button to select the fan speed in a range of Au%-F%, in conjunction with Temp + or Temp —...
Page 9
VIVAX SETTING THE TIMER FUNCTION Your air conditioning unit has two timer-related functions: TIMER ON - sets the amount of timer after which the unit will • automatically turn on. TIMER OFF - sets the amount of time after which the unit will •...
Page 10
VIVAX TIMER OFF function The TIMER OFF function allows you to set a period of time after which the unit will automatically turn off, such as when you wake up. 1. Press the Timer button, the Timer off indicator "...
Page 11
VIVAX Setting both TIMER ON and TIMER OFF at the same time Keep in mind that the time periods you set for both functions refer to hours after the current time. For example, say that the current time is 1:00 PM, and you want the unit to turn on automatically at 7:00 PM.
Page 12
VIVAX Unit turns Unit turns Time starts 2.5 hours later 5 hours later Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM. HOW TO USE THE ADVANCED FUNCTIONS...
Page 13
VIVAX LED display Press LED Press this button button more than 5 seconds(some units) Keep pressing this button more Press this button to turn on and turn than 5 seconds, the indoor unit will off the display on the indoor unit.
Page 14
VIVAX Silence function: Keep pressing Fan button for more than 2 seconds to activate/disable Silence function(some units). Due to low frequency operation of compressor, it may result in insufficient cooling and heating capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button while operating will cancel silence function.
Page 15
VIVAX Some units Active clean function( Follow me function( (some units) : The FOLLOW ME function enables The Active Clean Technology washes the remote control to measure the away dust, mold, and grease that may temperature at its current location...
Page 16
VIVAX 1. FEATURES AND FUNCTIONS OF WIRED CONTROLLER Feature: Malfunction code display: it can display the error code, helpful for service. 4-way wire layout design, no raised part at backside, more convenient to place the wires and install the device. Room temperature display.
Page 17
VIVAX 3. WIRE CONTROLLER ICON MEANING 1. Operation mode indication 8. PTC function indication 2. Fan speed indication 9. C° / F° indication 3. Left-right swing indication 10. Temperature display 4. Up-down swing indication 11. Lock indication 5. Faceplate function indication 12.
Page 18
VIVAX 5. OPERATION Remote signal receiving function The wired remote controller can be a remote signal receiving device, you can use the wireless remote controller to control the air-conditioner through the wired remote controller when the system have been powered on.
Page 19
VIVAX Room temperature sensor selection Indoor unit Follow me ptc Press the Follow me/PTC button to select whether the room temperature is detected at the indoor unit or the wire controller. When the Follow me function indication appears,the room temperature is detected at the wire controller.
Page 20
VIVAX 2. Push the Mode(A/B) button to select Unit A or Unit B, the wire controller select in a sequence that goes from(this step do not need to perform if the wire controller is connected with one unit only): 3. Press the button “+” and “-” to control the lift and drop of the faceplate.
Page 21
VIVAX 6. TIMER FUNCTIONS WEEKLY timer Use this timer function to set operating times for each day of the week. On timer Use this timer function to start air conditioner operation. The timer operates and air conditioner operation starts after the time has passed.
Page 22
VIVAX 7. WEEKLY TIMER Day of the week setting confirm Press the button “ + ” and “ - ” to select the day of the week.and then press the Press the Timer button to select the CONFIRM button to confirm the setting.
Page 23
VIVAX To set the DAY OFF (for a holiday) confirm Press the button “ + ” and “ - ” to select During the weekly timer, press the the day to set the DAY OFF. Confirm button to set the day.
Page 24
VIVAX Other days can be copied by repeating step 4 and 5. confirm Other days can be copied by repeating step 4 and 5. Press the Back button to back to the weekly timer. 7. WEEKLY TIMER Delete the time scale in one day During the weekly timer, press the Confirm button.
Page 25
VIVAX 8. FAULT ALARM HANDING If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident, investigate the system according to the following procedures. MALFUNCTION & PROTECTION DEFINE DISPLAY DIGITAL TUBE Error of communication between wire controler...