Summary of Contents for Exepd AB1 3 Series

  • Page 1 Control and Signal Devices AB1-[D/E/K/M/N/P/W]3- ****** Exepd GmbH i_PARK TAUBERFRANKEN 23 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de...
  • Page 2: Table Of Contents

    Operation, maintenance and troubleshooting ............ 7 Installation in a housing/device of the type of protection increased safety "e" and protection by housing "t" ..................8 Accessories, spare parts ................. 8 Service address .................... 8 AB1-X3-YB002eng 31.07.2023 www.exepd.de page 2 of 8...
  • Page 3: Product Description

    Ex d gaps cannot be changed). 3. Applied Standards EN IEC 60079-0 / General requirements EN 60079-1/ Flameproof enclosure EN IEC 60079-7 / Increased safety EN 60079-31 / Protection by housing AB1-X3-YB002eng 31.07.2023 www.exepd.de page 3 of 8...
  • Page 4: Type Key

    Explosion protection: (Exact data see type plate / information plate) II 2G Ex db eb IIC T6 Gb  II 2D Ex db IIIC T85 °C Db  Associated EU Declaration of Conformity: AB1-X3-YC0001 Type examination certificate: IBExU22ATEX1083 X AB1-X3-YB002eng 31.07.2023 www.exepd.de page 4 of 8...
  • Page 5: Technical Data Indicator Light Ab1-M3

    92mm (with mushroom print attachment) Electrical metrics 1-3 switching elements (break contact positively separated, auxiliary contact changeover) Rated voltage: 24 VDC/230 VAC Permissible rated current: ≤1 A Connecting cable: max.7x0.5 mm² Protection class II (protective insulation) AB1-X3-YB002eng 31.07.2023 www.exepd.de page 5 of 8...
  • Page 6: Technical Data Key Switch Ab1-K3

    "t" or by a suitable device Attachment/installation location. The metal housing of the control and signal device must be included in a suitable grounding/potential equalization dimension, e.g., through suitable installation or using grounding lugs. AB1-X3-YB002eng 31.07.2023 www.exepd.de page 6 of 8...
  • Page 7: Assembly And Installation

    Maintenance work and work to eliminate faults may only be carried out by trained specialist personnel. Before maintenance and/or troubleshooting, the specified safety regulations must be observed. The warnings on the devices must be observed! Before recommissioning, the applicable laws and guidelines must be observed. AB1-X3-YB002eng 31.07.2023 www.exepd.de page 7 of 8...
  • Page 8: Protection By Housing "T

    Tightening torque: 8 Nm 12. Accessories, spare parts Locking screw Grounding set (tab with nut) metal nut 13. Service address Exepd GmbH i_PARK TAUBERFRANKEN 23 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de www.exepd.de...