Bosch Sensortec | BME280 User Manual
4.6 Reset Sensor
▪
Resetting the sensor is possible by cycling VDD level or by writing soft reset command
4.6.1 PO Reset
▪
Power-On Reset option resets the logic part and register values after both VDD and VDDIO reach their
minimum levels
▪
Once PO Reset button clicked, sensor reset to default values and UI reflect the default values
4.6.2 Soft Reset
▪
Soft Reset option is used to erase the possible old settings
▪
Once Soft Reset button clicked, the default values would be updated in UI
4.7 Data Export/ Log
▪
To save the output values plotted by DD2.1 UI , go to Panels -> Data Export, or click Alt+D.
▪
By default, the data values are logged into a text (.txt) file in the destination folder of DD2.1 UI.
▪
The steps to follow data logging are as seen:
© Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution,
as well as in the event of applications for industrial property rights
Figure 17 : Sensor Metrics
16 | 23
Document number: BST-BME280-DSxxx-yy