PRL-1600C C Series Wireless Pulse Link System Technical Manual Revision: C1 Date: 12/15/2023 Solid State Instruments A division of Brayden Automation Corporation 6230 Aviation Circle Loveland, CO, USA 80538 (970)461-9600 e-mail: support@brayden.com...
Introduction The PRL-1600C Pulse Radio Link is a Transmitter and Receiver system that wirelessly sends up to four channels of KYZ pulses from the transmitter to a paired receiver. The short-hop PRL-1600C has a range of up to 5,000 feet depending on site topography and solves the problem of getting pulses across parking lots, vacant lots, roads, railroad tracks or other obstacles.
Packet Transmissions and Receptions are visually indicated with LEDs on both base and radio/antenna units. SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail:support@brayden.com...
It has been reported that other high-power RF transmitters mounted within close proximity can jam or corrupt the signal even though they are not using the same frequencies. SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail:support@solidstateinstruments.com...
INSTRUCTION SHEET PRNT-1600C PULSE RADIO TRANSMITTER FCC ID: TIT-PRT-1600 Transmitter Radio/Antenna PRNT-1600C PCB Assembly PRNT-1600C (Tx) Transmitter/ Transmitter/ Antenna Spring-loaded Antenna Unit 1 2 3 4 5 6 7 8 9 Lever (Press Board down to open) Insert wire Ty-Rap holes here and for Cable release lever...
Page 7
INSTRUCTION SHEET PRT-1600 PULSE RADIO TRANSMITTER (con't) PRNT-1600C PRT-16C Transmitter/ Transmitter Antenna Unit Base Unit 8-Conductor 24AWG Control (Not to Scale) Cable with shield -100' max. POWER INPUT - The PRNT-1600C receives its power supply from the PRT-16 Transmitter Base unit. METER INPUTS - See the PRT-16C Base Unit Instruction Sheet (page 10) for detailed information on connecting the K-Y pulse inputs to the Electric Meter's KYZ Pulse output.
Page 8
SDO- SHIELD SILVER *** NOTE:*** The Shield MUST be SILVER connected for proper operation. CONTROL CABLE TO BASE UNIT SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail: support@brayden.com Revision: 12/15/23...
***Do not switch #8 UP if the system is already TABLE 3 TABLE 4 paired.*** Input Mode SW#7 Run/Learn SW#8 FORM A (2W) FORM C (3W) LEARN SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail: support@brayden.com Revision: 12/15/23...
Page 10
PRNT-1600C Transmitter/Antenna Unit. For best results, it is advisable to keep this length of this cable to the minimum practical distance. STATUS LED's - These LED's indicate current system status. See Page 21. SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail: support@brayden.com...
For best results, keep the distance between the Receiver and the Base Unit to the minimum practical distance. When PCBA installation is complete, secure cap to mounting bracket using sheet metal screw in slot. SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, CO 80538 Phone: (970)461-9600 E-mail:support@brayden.com...
Page 12
INSTRUCTION SHEET PRR-1600C PULSE RADIO RECEIVER (con't) PRNR- Dip Switch S1 1600C PRR-16C Receiver/ Receiver Antenna Unit Base Unit 8 conductor #24AWG shielded Control Cable -100' (Not to Scale) max. POWER INPUT - The PRNR-1600C receives its power supply from the PRR-16 Receiver Base unit. PULSE OUTPUTS - See the PRR-16C Base Unit Instruction Sheet for detailed information on connecting the KYZ Outputs to the receiving device.
Page 14
MOVs on board. STATUS LED's - These LED's indicate current system status. See Page 22 & 23. SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail:support@brayden.com...
Page 15
SDO- SHIELD SILVER *** NOTE:*** The Shield MUST be SILVER connected for proper operation. CONTROL CABLE TO BASE UNIT SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail: support@brayden.com Revision: 12/15/23...
Form A mode, each set (Y1-Y2 and Y3-Y4) must be operated at the same voltage, from the same voltage source. Four 2W outputs OUTPUT #2 OUTPUT #1 SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail:support@brayden.com Revision: 12/15/23...
During extremely heavy rain, transmissions may not be reliable. REVISIONS Solid State Instruments PRL-1600C div. of DATE DESCRIPTION Wireless Pulse Link Brayden Automation Corp. System Diagram 6230 Aviation Circle Loveland, CO 80538 DATE ORIGINAL SCALE (970)461-9600 12/15/23 www.solidstateinstruments.com LATEST REVISION JOB NO.
Troubleshooting and Tech Support 1.) Use shielded 8-conductor control cable between the PRT-16C Transmitter Base Unit and the PRNT-1600C Transmitter/Antenna unit, as well as between the PRR-16C Receiver Base Unit and the PRNR-1600C Receiver/Antenna unit. Solid State Instruments’ part number 0715- 1005 is a the standard indoor-rated 8-conductor #24AWG shielded control cable sold by the foot.
Page 20
8. The system’s maximum reliable transmission distance will change with each installation since it is dependent on all of the environmental and electrical factors of each particular installation. While the distance is nominally specified as up to 5,000 feet, it may not work at the full range in some installations. 9.
Appendix A - PRT-1600C Dip Switch Settings and LED Indicators PRT-16C Transmitter Base DIP Switch Settings V1.20 LED1-LED5 # of SPI Hop Sequence Not Used Input Mode Learn Mode Timeout (10 minutes) Transmissions DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8 Enabled Form C...
Page 22
Appendix B - PRR-1600C Dip Switch Settings and LED Indicators PRR-16C Receiver Base DIP Switch Settings V1.20 LED1-LED5 Hop Sequence Fixed Pulse Width Not Used RSSI Enable Learn Mode Timeout (10 minutes) DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8 Enabled 100mS Enabled...
Page 23
RUN operations, that indicates an overrange error, that too many pulses have been received to output them in 10 seconds. SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail:support@brayden.com...
Page 24
LEARN Mode - During the LEARN mode, LED #2 RED should blink slow, about 1 blink per second, while it is learning. When it is done learning, it will blink about 4 times per second. SOLID STATE INSTRUMENTS a division of Brayden Automation Corp. 6230 Aviation Circle, Loveland, Colorado 80538 Phone: (970)461-9600 E-mail:support@brayden.com...
FCC / IC NOTICES This product contains FCC ID: OJM-HUMA-900 / IC: 5840A-HUMA900 This device complies with Part 15 of the FCC rules and Industry Canada license-exempt RSS standards. Operation of this device is subject to the following two conditions: 1. This device may not cause harmful interference, and 2.