INSTALLATION/USE INSTRUCTIONS
All connections MUST
be made with the electri-
cal supply switched off
and the batteries discon-
nected.
GENERAL WARNINGS
This manual is intended for technically qualified and trained installers.
Mottura Serrature di Sicurezza S.p.A. thanks you for choosing this product and reminds you:
- Read the instructions very carefully before installing or doing any maintenance on the device.
- All assembly and connection procedures must be done according to Rules of Good Engineering as well as in conformity to law.
- DO NOT install this device in explosive environments or atmospheres or in the presence of flammable fumes/gases.
- DO NOT install this device on a door with risk of contact with water or atmospheric agents unless the door is adequately protected.
- Always disconnect the power supply and isolate all live parts before installing or doing any maintenance on the device. Take all possible precautions
to eliminate the risk of electrical shock when doing the installation and/or maintenance procedures described in this manual.
- The installer must give these instructions and all maintenance instructions to the user.
- Keep these instructions for future use and attach the sales receipt to validate the warranty.
- In case of problems, contact your authorized dealer only.
Mottura Serrature di Sicurezza S.p.A. may change the characteristics of the products described in these instructions at any time and without notice.
WARRANTY TERMS
This device has been inspected by Mottura Serrature di Sicurezza S.p.A. and is guaranteed against all manufacturing defects for the period
defined by Italian law; the period begins on the date of purchase as demonstrated by the sales receipt. The warranty is effective if the sales
receipt, bearing information identifying the device, is shown to the dealer or service personnel. The warranty covers the replacement or repair of
parts found defective due to faulty manufacture; shipping costs to and from service centers are charged to the customer.
In case of a repeated malfunction of the same origin or a malfunction that cannot be repaired, Mottura Serrature di Sicurezza S.p.A. may decide,
in its final judgment, to replace the entire device. The warranty on the replacement device will continue to the expiration of the original device.
If the device must be serviced at the customer's home, the customer is required to pay (if requested) a minimum charge to cover the transfer
costs of authorized service personnel.
Transport is at the customer's risk if the customer ships the device, and at the service personnel's risk if the device is picked up and transported
by service personnel.
LIMITS OF LIABILITY
The warranty does not cover damage deriving from:
- negligence, carelessness, or use other than as described below
- failure to protect the device before doing any procedure that may generate scrap or waste (welding, drilling of panels, drilling of structure, etc.) that prevents
its correct functioning
- maintenance work not conforming to these instructions or done by unauthorized personnel
- use of accessories/components that are not original Mottura products
- shipping of the device without the necessary precautions
- any circumstances not attributable to manufacturing defects.
Operating temperature: -10°C to +55°C. In addition, Mottura Serrature di Sicurezza S.p.A. declines all liability for any harm to persons or damage to property
deriving from failure to comply with all of the instructions and warnings contained in this manual.
12/24 V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 99.724 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mottura 99.724

  • Page 1 In case of a repeated malfunction of the same origin or a malfunction that cannot be repaired, Mottura Serrature di Sicurezza S.p.A. may decide, in its final judgment, to replace the entire device.
  • Page 2: Table Of Contents

    The user assumes all risks in case of use that does not comply with the description contained herein. Mottura S.p.A. is in no way responsible for any non-compliant and unforeseen uses for this product, which may cause problems or damage of any kind to people, animals, things and the environment.
  • Page 3: Introduction

    1 - INTRODUCTION Relay MODULE (99.724) to start up to an actuator previously stored access credentials. Access credentials can be a numeric code, a TAG RFID, or a fingerprint that can be inserted by means of a dedicated external device connected to the control unit.
  • Page 4: Set-Up Button Functions

    2 - SET-UP BUTTON FUNCTIONS Relay MODULE is factory set up end does not require any changes. The fol- lowing steps should only be performed only if needed to change the original setting. For example : replacing the keypad escutcheon with other device or if you change the system and want to change the behavior of the output relays.
  • Page 5: Electrical Wiring

    30V / 2A ac-dc If only the control unit is powered, we recommend that you use MOTTURA’s network adapter cod. 99.683. Relay contacts provide an impulse with a fixed duration of 1 sec. Please refer to the wiring diagrams provided before...
  • Page 6: Keypad Programming - Tag Management

    SERVICE TAG Press P (1) If the lock is new or has been reset, you can enter the programming mode using any free Mottura TAG! (2) which will become a MASTER TAG. To end, press “E” or wait for 30 seconds (exit time - timeout).
  • Page 7: Deleting Individual Tag

    5.3 DELETING INDIVIDUAL TAGS Enter master TAG Press P Press P Press P Enter TAG ERROR! MASTER TAG TAG not TAG deleted recognised WARNING : The master TAG used to enter the program- ming mode CANNOT be deleted. To end, press “E” or wait for 30 seconds (exit time - timeout). 5.4 DELETING ALL TAGS Press P Enter master TAG...
  • Page 8: Disabling/Enabling Service Tag Keys

    5.5 ENABLING/DISABLING SERVICE TAGS Press P Enter master TAG Press P Press P Press P SERVICE TAGS, if entered, are enabled 7 -ENABLE 7 - DISABLE SERVICE TAGS, if entered, are disabled To enable enter 1-2-3 and To disable enter 3-2-1 and Press P or E to exit Press P press E...
  • Page 9: Keypad Programming - Code Management

    6 - KEYPAD PROGRAMMING - CODE MANAGEMENT ONLY for escutcheons 99775/99776 before each operation, press any key to activate the escutcheon 6.1 MEMORIZING PERSONAL ACCESS CODES WARNING Enter a code composed of a minimum of 3 to a maximum Present Enter the code of 8 digits Press P...
  • Page 10: Deleting All Personal Access

    6.3 DELETING ALL PERSONAL ACCESS Present Press P MASTER TAG To exit, press "E" or wait 30 sec. Deleting CODES in (timeout). Type 9-8-7 progress and press E WARNING : If you push the "P" button, you will get the output from the programming.
  • Page 11: Double Relay Function

    7 - DUAL RELAY FUNCTIONING ONLY for escutcheons 99775/99776 before each operation, press any key to activate the escutcheon Where there are two relays, you have 10 seconds after entering your access credentials to select the RELAY to be closed by pressing: - "P"...
  • Page 12 Press 2 Fingerprint valid Enter the CODE Press E and press E IFingerprint FINGERPRINT scan Press 2 NOT valid Return to point 1 Enter TAG Press  Fingerprint valid Fingerprint FINGERPRINT scan Press  NOT valid Return to point 1 www.mottura.it...

Table of Contents