Installation & Operation - Whitehall P-10-M-SDP Instructions For Operation And Care

Excellence in hydrotherapy
Hide thumbs Also See for P-10-M-SDP:
Table of Contents

Advertisement

Installation Instructions:
NOTE: THESE INSTALLATION
INSTRUCTIONS ARE USED FOR ALL
WHITEHALL AND -SL MODELS 27
GALLONS OR MORE.
REFERENCE DRAWINGS
ASSEMBLIES
MOTOR/TURBINE
RAISING/LOWERING/NO SHELF
RAISING/LOWERING/SHELF/LG
DRAIN ELBOW/VALVE
CASTERS
THERMOMETER
ASSEMBLY PROCEDURE:
A-
TO INSTALL MOTOR/TURBINE ASSEMBLY 1 , LOOSEN
HANDLE 2 AND ALIGN AND ENGAGE MOTOR SUPPORT ROD
3 WITH RAISING AND LOWERING ASSEMBLY 4 . TIGHTEN
LEVER HANDLE 2 . NOTE: INTERNAL BUSHING MAY NEED
ADJUSTING.
B-
PLACE DISCHARGE NOZZLE 5 INTO STORAGE SOCKET 6
PROVIDED.
C-
TO INSTALL THERMOMETER; THREAD SENSING ROD 7 THRU
UPPER BRACKET 8 AND INTO LOWER BRACKET 9 BEFORE
TIGHTENING SCREW 10 .
D-
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
CLOCKWISE, THEN FULLY COUNTERCLOCKWISE TO
COMPLETELY LUBRICATE THE PLUNGER ASSEMBLY.
E-
PROVIDE ELECTRICAL SERVICE AND PROPERLY INSTALLED,
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) FOR MOTOR
SPECIFIED. MOTOR SPECIFICATIONS AVAILABLE ARE EITHER
120V AC / 60 HZ ON 15A CIRCUIT OR 240 V AC / 50 HZ ON 10A
CIRCUIT.
WARNING
WARNING
Turbine assembly is provided with a 3-way plug. The
third prong functions as a built-in ground and must be
plugged into a matching grounded GFCI receptacle to
properly ground the product.
OPERATION:
A-
FILL TUB AS DESIRED USING FILLER HOSE BY OTHERS.
WATER LEVEL SHOULD BE A MAXIMUM OF 4" BELOW THE
AND A MINIMUM OF 6" ABOVE BOTTOM OF PUMP 12 .
B-
TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY
CLOCKWISE. THIS PROVIDES MAXIMUM PRESSURE AND
AGITATION.
C-
TURN ON THE SWITCH 13 .
D-
ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY
PUSHING DOWN ON THE TOP OF THE MOTOR SUPPORT
CASTING 14 UNTIL THE PUMP 12 IS AT THE DESIRED
LOCATION AND TIGHTEN HANDLE 2 TO LOCK IN PLACE.
4
WHITEHALL MANUFACTURING • P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A.
Phone (800) 782-7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com
PAGE NUMBER
5/6
7
8
9
10
11
7
8
10
9
E-
ADJUST PRESSURE CONTROL VALVE HANDLE 11 TO
DELIVER DESIRED LEVEL OF AGITATION AND PRESSURE.
DRAINING PROCEDURE:
A-
IF A FLOOR DRAIN IS AVAILABLE USE THE DRAIN VALVE 15
LOCATED AT THE BOTTOM OF THE TUB.
B-
IF EMPTYING INTO A SINK, ROTATE PRESSURE CONTROL VALVE
HANDLE 11 COUNTER-CLOCKWISE, LOWER THE PUMP 12 TO
THE BOTTOM OF THE TUB. PLACE DISCHARGE NOZZLE 5 INTO
INTO SINK, TURN ON SWITCH 13 (NOTE: WHEN WATER STOPS
DISCHARGING FROM THE NOZZLE, TURN OFF THE SWITCH).
DRAIN RESIDUAL WATER USING DRAIN VALVE 15 OR DRY
SPONGE.
5
6
11
12
13
1
14
3
4
2
15