Atmel AViiVA SC2 Manual
Atmel AViiVA SC2 Manual

Atmel AViiVA SC2 Manual

Cameralink color linescan camera

Advertisement

Quick Links

Features
High Sensitivity and High SNR Performance Linear CCD Sensor
Monoline 1365 RGB Patterns (Total of 4096 Active Pixels)
Built-in Anti-blooming, No Lag
CameraLink
Data Format (Base Configuration)
High Data Rate up to 60 Mpixels/s
Flexible and Easy to Operate via Serial Control Lines:
– Exposure Time: 1 to 32,000 µs
– Gain: -2 dB to 22 dB by Steps of 0.035 dB
– Color Correction
– Trigger Mode: Free Run or External Trigger Modes
– Output Format: Serial (8/10/12 Bits) or Parallel RGB
– Digital Offset and Gain (For Contrast Expansion)
Flat-field Correction (Lens and Light Non-uniformity, FPN and PRNU Correction)
Multi-camera Synchronization
Single Power Supply: DC 12 to 24V
Very Compact Design: 56 x 60 x 39.4 mm (w, h, l)
High Reliability – CE and FCC Compliant
F (Nikon), T2 or M42 x 1 Mount Adapter (Lens Not Supplied)
Description
This smarter C2 is the perfect alternative for users looking for a cost-effective color
linescan camera. The Aviiva SC2 takes advantage of all the features that made the
success of the Aviiva family: accuracy, versatility and easy implementation:
Flat-field correction and contrast expansion functions.
Embedded white balance and color space correction.
A very compact mechanical design that incorporates a 4k color linear sensor.
Atmel manages the entire manufacturing process from the sensor to the camera.
The result is a camera able to operate in 8, 10 or 12 bits with dedicated
electronics offering an excellent signal-to-noise ratio.
Programmable settings let the user work at different integration times, gains and
offsets. The external clock and trigger allow synchronization of several cameras.
Applications
The performance and reliability of this camera make it suitable for machine vision
applications requiring low-cost color capture. Such applications can include print,
packaging inspection or part sorting. With this camera, one avoids the usual problems
observed with tri-linear sensors on optical alignment and object synchronization.
CameraLink
Color Linescan
Camera
AViiVA
SC2
Preliminary
5373A–IMAGE–03/04
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AViiVA SC2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Atmel AViiVA SC2

  • Page 1 This smarter C2 is the perfect alternative for users looking for a cost-effective color Preliminary linescan camera. The Aviiva SC2 takes advantage of all the features that made the success of the Aviiva family: accuracy, versatility and easy implementation: •...
  • Page 2 Typical Performances Table 1. Typical Performances Parameter Value Unit Sensor Characteristics at Maximum Pixel Rate Resolution 1365 RGB patterns or 4096 pixels pixels Pixel pitch µm Maximum line rate Anti-blooming x 150 – Radiometric Performances (Maximum Pixel Rate, Tamb = 25°C) Dynamic range 12 (also configurable in 8 or 10) Spectral range...
  • Page 3: White Balance

    IR cut-off filter in front of the sensor. The AViiVA SC2 sensor has been cali- brated with a 2 mm BG38. The AViiVA SC2 is available with or without a 2 mm BG38 (refer to “Ordering Codes” on page 21).
  • Page 4: Camera Description

    Camera Description Figure 2. Camera Synoptic Power supplies DC power Even pixels analog chain DATA PGA, CDS, ADC CameraLink 12-bit at 30 Mpixels/s transceiver Linear CCD STROBE, 2 taps LVAL Sequencer controller Odd pixels analog chain PGA, CDS, ADC TRIG1, 12-bit at 30 Mpixels/s Image TRIG2...
  • Page 5: Standard Conformity

    A CameraLink data transfer cable ref. 14B26-SZLB-500-OLC (3M • A linear AC-DC power supply Atmel recommends using the same configuration to ensure compliance with the standards described hereafter. CE Conformity All AViiVA cameras comply with the requirements of the EMC (European) directive...
  • Page 6 Camera Command and Control The camera is configured through the serial interface. Please refer to “Serial Communication” on page 15 for the serial line’s detailed protocol. Table 2. Camera Command and Control Setting Command Parameter Description Gain -65 to 643 Gain setting from -2 to 22 dB (~0.035 dB steps) Even gain 0 to 56...
  • Page 7 AViiVA SC2 [Preliminary] Table 2. Camera Command and Control (Continued) Setting Command Parameter Description WB recall 1 to 4 Restores the white balance factors from WB banks 1 to 4 WB storage 1 to 4 Stores the active white balance factors in WB banks 1 to 4 1 to 4 Apply “user matrix 1 to 4”...
  • Page 8: Synchronization Mode

    8. Matrix coefficients R″ CRR CRG CRB R′ × G″ CGR CGG CGB G′ B″ CBR CBG CBB B′ 9. Switch off all lights before starting the FPN (dark) calibration. This calibration must be done before the PRNU calibration. 10. Place a white reference in front of the camera before starting the PRNU (white light) calibration. The light level must be between half and full dynamic range.
  • Page 9 AViiVA SC2 [Preliminary] Triggered Mode with Integration Time Setting The integration period starts immediately after the rising edge of the TRIG1 input signal and is set by the serial line. This period is immediately followed by a readout period. The readout time depends on the number of pixels and the pixel rate.
  • Page 10 Trigger and Integration Time Controlled by Two Inputs The TRIG2 signal’s rising edge starts the integration period and the TRIG1 signal’s rising edge stops the integration period. This period is immediately followed by a readout period. Table 6. Trigger and Integration Time Controlled by Two Inputs Label Description Integration time duration...
  • Page 11 AViiVA SC2 [Preliminary] Figure 7. Timing Diagram Internal Clock CLK_IN CLK_IN (case H=0) LVAL Always set to 1 DVAL STROBE DATA First valid pixel (1) Last valid pixel (4096) Parallel RGB Mode In this mode the color pixels are output in parallel. The data format is 8 bits for each color and the test pattern can replace the CCD data (T command).
  • Page 12 Figure 8. Timing Diagram Internal Clock CLK_IN CLK_IN (case H=0) LVAL DVAL STROBE DATA RED R1365 DATA GREEN G1365 DATA BLUE B1365 First valid data (1) Last valid data (1365) AViiVA SC2 [Preliminary] 5373A–IMAGE–03/04...
  • Page 13 AViiVA SC2 [Preliminary] Camera If multiple cameras are synchronized (there is more than one camera on one acquisition Synchronization board): • The “master” camera provides DATA, STROBE and LVAL signals to the acquisition board. The other cameras only provide DATA. •...
  • Page 14: Electrical Interface

    Electrical Interface Power Supply We recommend inserting a 1 amp fuse between the power supply and the camera. Table 9. Power Supply Signal name Type Description – DC power input: +12V to +24V (±0.5V) – Electrical and mechanical ground I = Input, O = Output, IO = Bi-directional signal, P = Power/ground, NC = Not connected Camera Control The CameraLink interface provides three LVDS signals dedicated to camera control (CC1 to CC4).
  • Page 15: Serial Communication

    AViiVA SC2 [Preliminary] Serial The CameraLink interface provides two LVDS signal pairs for communication between the Communication camera and the frame grabber. This is an asynchronous serial communication based on the RS-232 protocol. The serial line’s configuration is: • Full duplex/without handshaking. •...
  • Page 16: Connector Description

    Connector All connectors are on the rear panel. Description Note: Cables for digital signals must be shielded twisted pairs. Power Supply The camera connector type is a Hirose HR10A-7R-6PB (male). The cable connector type is a Hirose HR10A-7P-6S (female). Table 13. Power Supply Connector Pinout Signal Signal Figure 9.
  • Page 17: Bit Assignments

    AViiVA SC2 [Preliminary] Bit Assignments The following bit assignments are compliant with the CameraLink specification in the base configuration. Table 15. Bit Assignments When Used in RGB Serial Mode with 12-bit Data DS90CR285 DS90CR285 DS90CR285 DS90CR285 Pin Name Pin Name Pin Name Pin Name DATA-00...
  • Page 18 Table 18. Bit Assignments When Used in RGB Parallel Mode (3 x 8-bit Data) DS90CR285 DS90CR285 DS90CR285 DS90CR285 Pin Name Pin Name Pin Name Pin Name RED-00 RED-07 BLUE-02 Tx19 GREEN-05 Tx14 RED-01 GREEN-00 BLUE-03 Tx20 GREEN-06 Tx10 RED-02 GREEN-01 BLUE-04 Tx21 GREEN-07...
  • Page 19: Mechanical Characteristics

    AViiVA SC2 [Preliminary] Mechanical Characteristics Weight The camera’s typical weight (without lens or lens adapter) is 220g or 7.7 ounces. Dimensions The camera’s dimensions, without the lens, are: • 56 mm width • 60 mm height • 39.4 mm length Figure 10.
  • Page 20: Sensor Alignment

    Sensor Alignment Figure 11. Sensor Alignment Diagram Y axis First pixel center y + ∆y ∆θx, y Active area Mechanical reference point x + ∆x X axis Z axis Active area center z + ∆z ∆tilt Mechanical reference point X, Y plans Mounting of Lens (Lens not Supplied) The camera can be provided with a Nikon F, T2 or M42 x 1 mount.
  • Page 21: Ordering Codes

    AViiVA SC2 [Preliminary] Ordering Codes Table 19. Ordering Code Part Number Resolution Description AT71SC2CL4010-BA0 4096 AViiVA SC2 CL 4010 without BG38 filter AT71SC2CL4010-BA1 4096 AViiVA SC2 CL 4010 with BG38 filter AT71KFPAVIVA-ABA – F mount (NIKON) AT71KFPAVIVA-AKA – T2 mount (M42 x 0.75) AT71KFPAVIVA-ADA –...
  • Page 22 No licenses to patents or other intellectual property of Atmel are granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical components in life support devices or systems.

This manual is also suitable for:

At71sc2cl4010-ba0At71sc2cl4010-ba1