Download Print this page

Orientalmotor World K Series Operating Manual

Terminal box type 6 w
Hide thumbs Also See for World K Series:

Advertisement

Quick Links

O P E R AT I N G M A N U A L
World K Series
Terminal Box Type 6 W
Induction Motors and
Reversible Motors
Introduction
„ Before using the motor
Only qualified personnel should work with the product. Use the product correctly
after thoroughly reading the section "Safety precautions. " In addition, be sure to
observe the contents described in warning, caution, and note in this manual.
The product described in this manual has been designed and manufactured to be
incorporated in general industrial equipment. Do not use for any other purpose.
Oriental Motor Co., Ltd. is not responsible for any damage caused through failure to
observe this warning.
Regulations and standards
„ UL Standards, CSA Standards, CCC System
This product is recognized by UL under the UL and CSA Standards, and also certified
by CQC under the China Compulsory Certification (CCC) system.
The motor model name represents the model that conforms to the standards.
Applicable standards
UL 1004-1, UL 1004-2
CSA C22.2 No.100, CSA C22.2 No.77
GB/T 12350
• Thermal Class: 130 (B)
z Standards for accessories
Capacitor: UL File No.E83671 (CYWT2),
VDE License Nos.112847 (capacitors with a rated voltage of 250 VAC),
114747 (capacitors with a rated voltage of 450 VAC)
Capacitor cap: UL File No.E56078 (YDTU2)
„ CE Marking
This product is affixed the CE Marking under the Low Voltage Directive.
z Low Voltage Directive
• Applications standards
EN 60034-1, EN 60034-5, EN 60664-1, EN 60950-1
• Installation conditions
(For EN standard)
Overvoltage category
, Pollution degree 3 (except for the motor mounting surfase),
Class
equipment
• Motor temperature rise tests
Temperature rise tests required by the standards are conducted for the pinion shaft
type motors in a state of attaching a gearhead.
The tests for the round shaft type motors are conducted in a state of attaching a heat
radiation plate.
Heat radiation plate size: 115×115 mm (4.53×4.53 in.), thickness: 5 mm (0.20 in.),
material: aluminum alloy
„ Electrical Appliance and Material Safety Law
The three-phase round shaft motor type bears a
„ RoHS Directive
The products do not contain the substances exceeding the restriction values of RoHS
Directive (2011/65/EU).
HM-9249-7
Certification Body / File No.
UL /UL File No.E64199
CQC
mark.
Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and safety
precautions.
• Please read it thoroughly to ensure safe operation.
• Always keep the manual where it is readily available.
Safety precautions
The precautions described below are intended to prevent danger or injury to the
user and other personnel through safe, correct use of the product. Use the product
only after carefully reading and fully understanding these instructions.
Handling the product without observing the instructions that
WARNING
accompany a "Warning" symbol may result in serious injury or
death.
Handling the product without observing the instructions that
CAUTION
accompany a "Caution" symbol may result in injury or property
damage.
The items under this heading contain important handling
Note
instructions that the user should observe to ensure safe use of
the product.
• Do not use the product in explosive or corrosive environments, in the
presence of flammable gases, locations subjected to splashing water, or near
combustibles. Doing so may result in fire, electric shock or injury.
• Assign qualified personnel the task of installing, wiring, operating/
controlling, inspecting and troubleshooting the product. Failure to do so
may result in fire, electric shock or injury.
• Do not transport, install the product, perform connections or inspections
when the power is on. Always turn the power off before carrying out these
operations. Failure to do so may result in electric shock.
• The motor is class
equipment. Install the motor so as to avoid contact with
hands, or ground it to prevent the risk of electric shock.
• Install the motor in an enclosure in order to prevent electric shock or injury.
• Keep the input-power voltage within the specification to avoid fire and
electric shock.
• Connect the cables securely according to the connection diagram in order to
prevent fire and electric shock.
• Do not forcibly bend, pull or pinch the lead wires. Doing so may result in fire
and electric shock.
• Be sure to insulate the connection terminal of the capacitor. Failure to do so
may result in electric shock.
• Turn off the power in the event of a power failure, or the motor will suddenly
start when the power is restored and may cause injury or damage to
equipment.
• Do not touch the connection terminal of the capacitor immediately after the
power is turned off (for a period of 30 seconds). The residual voltage may
cause electric shock.
• Do not disassemble or modify the motor. This may cause electric shock or
injury.
• Do not use the motor beyond its specifications, or electric shock, injury or
damage to equipment may result.
• Do not touch the motor during operation or immediately after stopping. The
surface is hot and may cause a burn.
• Do not hold the motor output shaft. This may cause injury.
• Keep the area around the motor free of combustible materials in order to
prevent fire or a burn.
• To prevent the risk of damage to equipment, leave nothing around the
motor that would obstruct ventilation.
• To prevent bodily injury, do not touch the rotating parts (output shaft) of the
motor during operation.
• When an abnormality is noted, turn off the power immediately, or fire,
electric shock or injury may occur.
• The motor surface temperature may exceed 70 °C (158 °F) even
under normal operating conditions. If the operator is allowed
to approach the running motor, attach a warning label as
shown in the figure in a conspicuous position. Failure to do so
may result in a skin burn(s).
WARNING
CAUTION
Warning label
1

Advertisement

loading

Summary of Contents for Orientalmotor World K Series

  • Page 1 O P E R AT I N G M A N U A L Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures and safety World K Series Terminal Box Type 6 W precautions.
  • Page 2: Installation

    Preparation Installation „ Checking the product „ Location for installation Verify that the items listed below are included. Report any missing or damaged items Install it in a well-ventilated location that provides easy access for inspection. The to the branch or sales office from which you purchased the product. location must also satisfy the following conditions: •...
  • Page 3 • Use the gearhead with pinion shaft which is identical with one of Note Three-phase type (Connection diagram: ② ) motor. • Do not forcibly assemble the motor and gearhead. Also, prevent The motor rotates in the clockwise direction (CW) if connected metal objects or foreign substances from entering in the gearhead.
  • Page 4: Operation

    „ Connection method to a terminal box Operation The motor rotates when the power supply is turned on. For protection against electric shock, do not turn on the power supply until the Terminal block wiring is complete. Terminal cover • Make sure that the motor case temperature does not exceed Note 90 °C (194 °F) when operating the motor.
  • Page 5: Troubleshooting

    Published in February 2022 • Please contact your nearest Oriental Motor o ce for further information. Technical Support Tel:800-468-3982 Singapore 8:30am EST to 5:00pm PST (M-F) Tel:1800-842-0280 www.orientalmotor.com www.orientalmotor.com.sg Schiessstraße 44, 40549 Düsseldorf, Germany Tel:1800-806-161 www.orientalmotor.com.my Technical Support Tel:00 800/22 55 66 22 www.orientalmotor.de...

This manual is also suitable for:

2ik6gn-aw2b2ik6gn-cw2b2ik6gn-sw2b2rk6gn-aw2b2rk6gn-cw2b