Vision sensor VDS 10 series operation manual catalogue Chapter 1: Product Introduction ..........................3 1.1 Product description ............................3 1.2 Main characteristics ............................3 1.3 Appearance introduction ..........................4 1.4 Definition of interface and scatter line ....................6 1.5 Accessories and dimensions ........................7 Chapter 2 Equipment Installation and Operation ..................8...
Page 3
Vision sensor VDS 10 series operation manual Chapter 6: List of FAQ ..............................34 6.1 Client software identified the device but showed "inaccessible"........34...
Chapter 1: Product Introduction 1.1 Product description This manual is applicable to Akusense vision sensor VDS 10 series, can be applied to 3C, food, electronic semiconductor, auto parts and other industries. Built-in a variety of depth vision detection tools, equipped with lighting, acquisition, processing, communication and other functions, excellent product performance provides reliable detection results for presence, negative, counting and other anti-error scenarios.
Vision sensor VDS 10 series operation manual 1.3 Appearance introduction A appearance description order number name description Visual sensor mounting hole for fixing screw the equipment M12-17 PIN cable, including power connecting line line, Ethernet cable, IO cable, serial port, function line...
Page 6
Vision sensor VDS 10 series operation manual B. Description of the status indicator light order number name description TRIG key Trigger the button TUNE key Automatic reference button Green light for normal equipment power light operation Green light strobe when the network communication is...
Vision sensor VDS 10 series operation manual 1.4 Definition of interface and scatter line The equipment interface is M12-17 PIN interface, and the specific pin signal definition is shown in the following figure. When wiring the equipment, please connect according to the pin number in the table and the color on the cable label.
Vision sensor VDS 10 series operation manual 1.5 Accessories and dimensions A inventory For the normal use of the equipment, please prepare the supporting items shown in the following table before installation. Accessories description picture name Connect the M12-17 PIN cable to...
Vision sensor VDS 10 series operation manual Chapter 2 Equipment Installation and Operation 2.1 Equipment installation 1. Install the equipment to the fixing bracket with screws, and then to other mechanism parts through the fixing bracket. Demo diagram: Front face installation...
Page 10
Vision sensor VDS 10 series operation manual 2. Install to tilt at 10-15 degrees to avoid spots and reflection. The liquid zoom sensor is 40mm-300mm Schematic diagram of the liquid-state zoom sensor installation The manual zoom sensor working distance is 30mm-300mm...
Vision sensor VDS 10 series operation manual 2.2 Power supply connection Power supply supports 24V DC, up to 3A. There are two power supply methods: support 24VDC direct connection or 220VAC with adapter connection.
Vision sensor VDS 10 series operation manual 2.3 Communication connection A RS232 Serial port connection The default port rate is 9600, check bit: NULL, data bit: 8, termination bit: 1. Actual parameters can be changed when debugging the software. B Ethernet linkage...
Vision sensor VDS 10 series operation manual Chapter 3 IO Electrical Characteristics and Wiring The visual sensor has two optical-coupled isolated inputs and three non-isolated outputs. 3.1 I / O electrical characteristics The LineIn 0 / 1 in the device I / O signal is the photocoupled isolation input, and the LineOut0 / 1 / 2 is the non-photocoupled isolation output.
Page 14
Vision sensor VDS 10 series operation manual 3.1.2 Output electrical characteristics The parameter name Parameter symbol parameter values Output logic is at a low 0.7V level Output logic is at a high 23.9V level Output drops along the 20.3μs delay Output rises along the 550μs...
Page 15
Vision sensor VDS 10 series operation manual Equipment input circuit diagram The input logic level is: Enter a logical level diagram 3.1.4 Input the internal wiring diagram output signal The Lineout0 / 1 / 2 in the device I / O signal is the output. The output voltage range from...
Vision sensor VDS 10 series operation manual Equipment output circuit diagram The output logic level is: Output logic level diagram 3.2 IO external wiring The device may receive the external input signal or the output signal to the external device through the I / O interface.
Page 17
Vision sensor VDS 10 series operation manual 3.2.1 Input the external wiring diagram Different types of equipment, equipment input wiring is different. The input signal is the NPN The input signal is the PNP 3.2.2 Output the external wiring diagram Different types of equipment have different output wiring of the equipment.
Vision sensor VDS 10 series operation manual explain *: 1) The voltage value of the VCC of the equipment shall not be higher than the voltage value of the sensor PWR, otherwise the output signal of the equipment will be abnormal.
Vision sensor VDS 10 series operation manual 9-pin header 232 serial port definition Note : The voltage value of VCC shall not be higher than that of PWR, otherwise the output signal of the equipment will be abnormal. Chapter 4: Client operations 4.1 Software Connection...
Vision sensor VDS 10 series operation manual revise IP 4.2 PC network configuration 4.2.1 Change the IP address of the PC The operation steps are as follows: 1) Take Windows10 as an example, turn "Start menu"> "Settings"> "Network and Internet", ">" Ethernet ">" More Adapter Options ">"...
Page 21
Vision sensor VDS 10 series operation manual 2) Open the configuration software, select the corresponding PC and click the connection to complete. 4.3.2 Change the sensor IP address The operation steps are as follows: open the configuration software, select the corresponding PC network card, display the sensor, click IP Settings>...
Vision sensor VDS 10 series operation manual Chapter 5: Function introduction 5.1 Introduction of the interface The device can operate through the client, specifically as follows: 1) Ensure that the device is accessible, and click the "Connect" of the client.
Vision sensor VDS 10 series operation manual 5.2 New scheme 5.2.1 Camera debugging It includes three items: camera parameter setting, camera trigger setting and parameter expansion. 5.2.1.1 Camera parameter settings Camera parameter setting: click to adjust, can adjust the brightness, white balance, focus, make the image clearer.
Page 24
Vision sensor VDS 10 series operation manual Continuous trigger: Continuous trigger means that the sensor continuously triggers to take a photo, and the trigger mode can be set directly on the software side. Software trigger: Software trigger means that the sensor triggers a photo after receiving the signal from the software.
Page 25
Vision sensor VDS 10 series operation manual One-button setting: you can adjust the brightness, exposure time, gain and other parameters with one button Adjust the focus: the focus value can be adjusted to reach a clear state. The values of the regulatory focus were all adjustable at 1 – 1023.
Page 26
Vision sensor VDS 10 series operation manual 5.2.2 Template addition Step 2 is to add the template and add the reference image. Click "+ Template Reference Image" to add the reference image of the template 5.2.2.1 Image registration Image registration: You can create a new image for the template.
Page 27
Vision sensor VDS 10 series operation manual 5.2.3 Tool Settings Step 3: Select a template and add tools to set up your tasks. Click "+ tool" to add 4 algorithm tools: position correction, with or without tool, counting tool, and pattern tool 5.2.3.1 Position correction...
Page 28
Vision sensor VDS 10 series operation manual Image algorithm tools are divided into: search area, adjust contour, and adjust threshold Search area: delimit the rectangular box and circle box in the search area, and click "rectangle" or "Circle" to search for the designated area in the preview window Adjust the outline: the outline is divided into low, middle and third grade.
Page 29
Vision sensor VDS 10 series operation manual "rectangle" or "Circle" to search for the designated area in the preview window Adjust the outline: the outline is divided into low, middle and third grade. Sliding the coordinate horizontal axis to adjust the contour sensitivity Adjustment threshold: adjustable similarity Spot presence: determine the presence and similarity of a specific line in the set area.
Page 30
Vision sensor VDS 10 series operation manual 5.2.3.3 Count tools Pattern count: Count the number of extracted color blocks (brightness blocks) within the set area. Set a threshold for the quantity to judge the similarity. OK: Calculate the number of shape pattern collections within the set area range. NG: Number less than the set area and size less than the set area.
Page 31
Vision sensor VDS 10 series operation manual Spot count: Count the number of extracted color blocks (brightness blocks) in the set area. Set a threshold for the quantity to judge the similarity. OK: Calculate the number of block pattern collections within the set area range. NG: Number less than the set area and size less than the set area.
Page 32
Vision sensor VDS 10 series operation manual 5.2.4IO output Configure the output-related parameters of the templates and tools within the protocol IO output is divided into three ways: IO 1, IO 2 and IO 3 Duration: minimum to 0, maximum to 100. Delay time: minimum to 0, maximum to...
Vision sensor VDS 10 series operation manual 5.3 Scheme management 5.3.1 Scheme operation Data reset: empty the data that can be identified, including the total number, NG, NG rate List of tools: Click "Adjust the threshold" and slide the coordinate horizontal axis to...
Page 34
Vision sensor VDS 10 series operation manual 5.3.2 Scheme switching Export the scheme, you can export the program to the computer Copy the scheme, you can copy one more layer scheme to the software interface Remove the current scheme Edit the current scheme...
Page 35
Vision sensor VDS 10 series operation manual Chapter 6 List of FAQ 6.1 Client software identified the device but showed "inaccessible" probable cause: 1) The IP of the device and the network card connected to the device are not in the same network segment.
Need help?
Do you have a question about the VDS 10 Series and is the answer not in the manual?
Questions and answers