Onicon Air Monitor VOLU-probe/1SS Installation Instructions Manual

Rectangular ducts

Advertisement

Quick Links

INSTALLATION PROCEDURE
VOLU-probe/1SS for Rectangular Ducts
WARRANTY
Air Monitor Corporation (hereinafter referred to as "Seller") warrants that at the time of shipment, products sold
pursuant to this contract will be free from defects in materials and workmanship, and will conform to the
specifications furnished or approved in writing by Seller. No warranty is given that delivered products will conform
to catalog sheets, data sheets, and the like, which are subject to change without notice.
Seller will repair or replace, at its option, any products listed under this warranty which is returned freight pre-
paid to Seller and within the earlier of one (1) year after start-up or fifteen (15) months after shipment, prove upon
test and examination by Seller to be defective within the terms of this warranty. The warranty period for any item
repaired or replaced shall be for the time remaining on the warranty period for the original components. Purchaser
shall notify Seller in writing of such defect within sixty (60) days of discovery of the defect.
This warranty does not extend to any product sold by Seller which has been the subject of misuse, neglect,
accident, damage or malfunction caused by interconnection with equipment manufactured by others, improper
installation or storage, or used in violation of instructions furnished by Seller, nor does it extend to any product
which has been repaired or altered by persons not expressly approved by Seller. Nor does Seller warrant
equipment against normal deterioration due to environment; nor items such as thermocouples, electrodes, and
similar items subject to wear or burnout through usage. Adjustments for items or equipment not manufactured
by Seller shall be made to the extent of any warranty of the manufacturer or supplier thereof.
Seller shall not be liable for any special or consequential damages or for loss of damage directly or indirectly
arising from the use of the products.
The warranty set forth above is in lieu of all other warranties either express or implied and constitutes the full extent
of Air Monitor Corporation's liability to the customer, or any other party for breach of warranty. THERE ARE NO
EXPRESS WARRANTIES EXCEPT AS SET FORTH HEREIN. THERE ARE NO IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, WHICH ARE PARTICULARLY
DISCLAIMED.

Advertisement

loading

Summary of Contents for Onicon Air Monitor VOLU-probe/1SS

  • Page 1 INSTALLATION PROCEDURE VOLU-probe/1SS for Rectangular Ducts WARRANTY Air Monitor Corporation (hereinafter referred to as "Seller") warrants that at the time of shipment, products sold pursuant to this contract will be free from defects in materials and workmanship, and will conform to the specifications furnished or approved in writing by Seller.
  • Page 2 VOLU-probe/1SS for Rectangular Ducts – Installation Procedure INSPECTION & HANDLING. VOLU-probes should be carefully inspected for damage prior to inst allation. Report damage to your Freight Department, or cont act delivery carrier. Almost any means of handling can be utilized depending on the length and weight of the probes.
  • Page 3: Dimensional Specifications

    VOLU-probe/1SS for Rectangular Ducts – Installation Procedure FASTENERS. Gasket mounting surfaces should be clean and burr free. VOLU-probe mounting plates are predrilled for 1/4" mounting fasteners. Air Monitor recommends the use of 1/4-20 bolts, nuts, and lock washers (or flat washers and lock nuts).
  • Page 4 VOLU-probe/1SS for Rectangular Ducts – Installation Procedure INTERCONNECTING TUBING. Interconnecting tubing and fitting makeup is to be per Table 1 (see Page 5). Refer to illustrations below for typical tubing configurations.
  • Page 5: Tubing Size

    VOLU-probe/1SS for Rectangular Ducts – Installation Procedure SIGNAL TUBING. Signal tubing commences at the total and static pressure takeoff connections at the center of the interconnecting tubing array shown in Details B and C. Two signal tubing conditions are possible; tubing with an AUTO-purge panel and tubing without an AUTO-purge or CAMS panel.
  • Page 6: Airborne Contaminants

    VOLU-probe/1SS for Rectangular Ducts – Installation Procedure AIRBORNE CONTAMINANTS. The levels of air filtration and cleanliness associated with commercial HVAC Systems, whether supply/return/ exhaust/outside air, are satisfactory for operation of the VOLU-probe. Industrial applications containing airborne contaminants may require periodic manual or automatic cleaning using compressed air applied to the signal fittings, and/or removal from the duct or stack for physical cleaning.
  • Page 7 VOLU-probe/1SS for Rectangular Ducts – Installation Procedure CUSTOMER SERVICE. Air Monitor Corporation provides in-house technical support for all our products : Monday through Friday, 7 am to 5 pm (p st) Phone: 707-544-2706 or 1-800-AIRFLOW / Fax: 707-526-2825 If after contacting the Customer Service Department it is determined that equipment will require return to Air Monitor Corporation for further rep air, a Return Authorization number will be issued.