Download Print this page

Gates Radio Company FM- 20B Instruction Book page 24

Advertisement

o
u
RDC-10C
TB3-26
TB3-28
TB3-27
TB3-17
TB604
14
15
16
17
18
19
20
Studio Unit RDC-10C
Position #2.
Position #3
Position
# 4
Position #5
Position #6
Position #7
AMI;LIFIER
Raise function
Lower Function
Common
6V.
Stepper relay position
Ground
110V.
a.c.
from Driver
P.A. Plate Voltage
P.A. Plate Current
P.A. Power Output
P.A. Filament Voltage
Driver Plate Voltage
Driver Plate Current
REMOTE CONTROLLING THE GATES FM-20B
1.
Connect the two wires from the fail-safe relay in the re-
mote unit betwee n TB503-2 and TB503-3.
2.
Remove jumper between TB503-4 and TB503-3.
3.
Conneqt the momentary " on" function to these two terminals
for plate off.
4.
Connect two wires from remote unit to TB503-5 and TB503-6
for momentary plate on function.
5.
Place " local-Remote" switch.in " Remote" position.
6.
Place " Tune-Operate" switch in " Operate" position.
7.
Connect " Raise-Lower" function relays between 14,15 and
16 on TB604 with TB604-16 common.
8.
Connect interlocking voltage to TB604-17.
9.
Connect remote P.A. plate voltage meter to TB604-9.
10.
Connect remote P.A. plate current meter to TB604-7.
11.
Connect remote P.A. RF output meter to TB604-10.
12.
Connect reylote P.A.
filament volts to TB604-11.
13.
Connect remote driver plate voltage meter to TB503-8.
14.
Connect remote driver plate current meter to TB503y7.
6/22/61
-19-
FM-20B

Advertisement

loading