Advertisement
Not for use with compressors without time delays.
24 Volts A.C.
Electrical Rating: 24 to 30 Volts A.C.
Heat Anticipator: 0.20 to 1.2 Amp. Max.
Cool Anticipator: 0 to 1.0 Amp. Max.
The proper location of the room thermostat is most important to insure that it will provide a comfortable home temperature. Observe the following general rules when selecting a location:
The heating side of this thermostat is equipped with an adjustable heater. Set heater indicator to match the current rating of the primary control. The heater may be adjusted for current ratings from.2 to 1.2 Amp.
Additional adjustments, if necessary, may be made as follows:
BURNER CYCLES TOO LONG - Set adjustable heater to a slightly lower dial setting (1/2 division).
BURNER CYCLES TOO SHORT - Set adjustable heater to a slightly higher dial setting (1/2 division).
The Adjustable Heater (Heat Anticipator) WILL BURN OUT if 25V are applied directly to thermostat by shorting out the gas valve or primary control during testing or by incorrect wiring.
* If replacing a Honeywell TM-11, tape off wire "R"; connect wire "B" to terminal "RH."
** If replacing a Honeywell thermostat with a clock wire "C," tape off wire "C"
TYPICAL HOOKUP FOR 2-WIRE 24V HEATING SYSTEM AND MILLIVOLT SYSTEM
* If both Y and C wire are present, tape off "C" wire.
TYPICAL HOOKUP FOR 3-WIRE SYSTEM IF THIRD WIRE IS FAN WIRE
* If both Y and C wire are present, tape off "C" wire.
TYPICAL COOLING AND HEATING SYSTEM (4-WIRE)
* If both Y and C wire are present, tape off "C" wire.
TYPICAL COOLING AND HEATING SYSTEM (5-WIRE)
NOTE
if you have an electric system and the blower does not operate after installation, find the factory installed yellow wire currently attached to the "Y" terminal and move it to the "A" terminal on the sub-base.
If you require assistance, please contact our Technical Assistance Department at 856-2348803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproducts.com. Our web site offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.
© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download LUX CH200SA, CH400SA - VERSATILE DELUXE LOW VOLTAGE THERMOSTAT Manual
Advertisement
Need help?
Do you have a question about the CH200SA and is the answer not in the manual?
Questions and answers