LUX CH200SA, CH400SA - VERSATILE DELUXE LOW VOLTAGE THERMOSTAT Manual

Advertisement

LUX CH200SA, CH400SA - VERSATILE DELUXE LOW VOLTAGE THERMOSTAT Manual

SPECIFICATIONS

Device Appearance


Not for use with compressors without time delays.

24 Volts A.C.
Electrical Rating: 24 to 30 Volts A.C.
Heat Anticipator: 0.20 to 1.2 Amp. Max.
Cool Anticipator: 0 to 1.0 Amp. Max.

SELECTING THE DEVICE LOCATION

The proper location of the room thermostat is most important to insure that it will provide a comfortable home temperature. Observe the following general rules when selecting a location:

  1. Locate it about 5 ft. above the floor with a free flow of air.
  2. Install it on a partitioning wall, not on an outside wall.
  3. Never expose it to direct light or radiation from lamps, sun, fireplaces, etc.
  4. Avoid locations close to doors that lead outside, windows, or adjoining outside walls.
  5. Avoid locations close to radiators, warm air registers, or in the direct path of heat from them.
  6. Make sure there are no pipes or duct work in that part of the wall chosen for the thermostat location.
  7. Never locate it in a room that is warmer or cooler than the rest of the home such as kitchen or hallway or on the opposite side of the wall of a cold or unused room.
  8. The living or dining room is normally a good location, provided there is no cooking range or refrigerator on opposite side of wall.

INSTALLATION

  1. Remove cover from thermostat by pulling outward. Pull thermostat wires through small holes beside terminal screws on thermostat base and connect wires to proper terminal screws per wiring diagrams. Note that on some models wire leads may be connected to terminal screws on back of base.
  2. The thermostat can either be mounted to a standard horizontal outlet box or mounted directly to the wall. Place level on top of thermostat base and mark hole locations for mounting screws. Push excess wire into wall or switch box and plug up hole to prevent drafts from affecting thermostat operation. Then attach thermostat base loosely to wall with the two screws provided.
  3. Again place level on top of thermostat base to be sure itis level. Then tighten mounting screws securely and snap on thermostat cover.

HEATING ANTICIPATOR

The heating side of this thermostat is equipped with an adjustable heater. Set heater indicator to match the current rating of the primary control. The heater may be adjusted for current ratings from.2 to 1.2 Amp.

Additional adjustments, if necessary, may be made as follows:
BURNER CYCLES TOO LONG - Set adjustable heater to a slightly lower dial setting (1/2 division).
BURNER CYCLES TOO SHORT - Set adjustable heater to a slightly higher dial setting (1/2 division).


The Adjustable Heater (Heat Anticipator) WILL BURN OUT if 25V are applied directly to thermostat by shorting out the gas valve or primary control during testing or by incorrect wiring.

WIRING DIAGRAMS

Heating Systems

WIRING DIAGRAMS - Heating Systems
* If replacing a Honeywell TM-11, tape off wire "R"; connect wire "B" to terminal "RH."
** If replacing a Honeywell thermostat with a clock wire "C," tape off wire "C"


TYPICAL HOOKUP FOR 2-WIRE 24V HEATING SYSTEM AND MILLIVOLT SYSTEM

Cooling Systems

WIRING DIAGRAMS - Cooling Systems
* If both Y and C wire are present, tape off "C" wire.


TYPICAL HOOKUP FOR 3-WIRE SYSTEM IF THIRD WIRE IS FAN WIRE

Heating/Cooling Systems

4 or 5-Wire with One Transformer

WIRING DIAGRAMS - Heating/Cooling & 1 transformer
* If both Y and C wire are present, tape off "C" wire.


TYPICAL COOLING AND HEATING SYSTEM (4-WIRE)

5 or 6-Wire with Two Transformers

WIRING DIAGRAMS - Heating/Cooling & 2 transformers
* If both Y and C wire are present, tape off "C" wire.


TYPICAL COOLING AND HEATING SYSTEM (5-WIRE)

NOTE
if you have an electric system and the blower does not operate after installation, find the factory installed yellow wire currently attached to the "Y" terminal and move it to the "A" terminal on the sub-base.

TECHNICAL ASSISTANCE

If you require assistance, please contact our Technical Assistance Department at 856-2348803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproducts.com. Our web site offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.

© 2007 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download LUX CH200SA, CH400SA - VERSATILE DELUXE LOW VOLTAGE THERMOSTAT Manual

Advertisement

Need help?

Need help?

Do you have a question about the CH200SA and is the answer not in the manual?

Questions and answers

Table of Contents