Saflec Systems SDC-650 Quick Start Manual

Multiple door controller

Advertisement

Quick Links

SDC-650
Multiple door controller
Revision 1.1 - (July 08, 2015)
Quick Start Guide
Introduction
The SDC-650 is a multiple door controller that can control up to 8 doors. It has five relay outputs
and eight inputs.
Up to 16 SDC controllers can be linked using a protected RS-485 network. The PC can connect to
it using either RS-232 or the built-in Ethernet connector or through the RS-485 network from
another controller.
It has a reader RS-485 network that can also connect up to sixteen slave devices including remote
I/O units.
The unit comes with a 12Vdc 5A power supply and a battery backup of 7Ah and is mounted in a
lockable case.
Figure 1
SDC-650 Controller board - labeled
Copyright© 2015 – Saflec Systems (Pty) Ltd.
http://www.saflecsystems.co.za

Advertisement

Table of Contents
loading

Summary of Contents for Saflec Systems SDC-650

  • Page 1 Quick Start Guide Introduction The SDC-650 is a multiple door controller that can control up to 8 doors. It has five relay outputs and eight inputs. Up to 16 SDC controllers can be linked using a protected RS-485 network. The PC can connect to it using either RS-232 or the built-in Ethernet connector or through the RS-485 network from another controller.
  • Page 2 SDC-650 Multiple door controller Introduction Figure 2 Possible position for an SDC-650 in a SACS access control system. Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 3 Right to move to the next character. This process would repeat until the entire password has been entered, then the Enter button is pressed to confirm. Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 4: Step 1: Connecting The Power Supply

    Step 2: Set the address using the configuration menu The SDC-650 communicates with other controllers via a multi-drop RS-485 communications network. Each controller on this network requires a unique address for communications and identification.
  • Page 5: Step 4: Connecting The Rs-485 Device Network

    All readers or IO expansion boards are connected to each other via an RS-485 multi-drop network which is connected to the controller as detailed in the figure below. Figure 6 Wiring configuration for an SSR reader on the RS-485 device network Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 6  Repeat the above process for the ‘Subnet Mask’ and ‘Gateway’ settings.  Once you’ve set everything correctly, browse through the pages until you get to a page entitled ‘Save Settings’. Press Enter to apply the change then reboot the controller. Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 7: Step 6: Connecting The Digital Inputs

    The outputs can provide 12Vdc power, or simply act as a potential free contact, allowing external DC or AC power to be switched through the relay. The configuration of this output mode can be accomplished using the jumpers J11 to J15. Possible output modes are listed below. Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 8 Make sure that sufficient power is available from the power supply for all internally switched outputs, for the controller and for any readers powered from the power supply. Figure 14 Example wiring for an internally powered magnetic lock – normally closed. Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 9 In order to do this a freewheeling diode (also known as flyback diode) should be connected across the load as seen in the figure below. Figure 15 Diagram showing freewheeling diode over an internally powered inductive load (eg. strike lock) – normally open. Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 10: The Web Interface

    ‘Netsilicon’. These passwords can be changed from the ‘Change Password’ link at the bottom. Figure 16 The Change Password page before and during password change When the password is entered and verified a save button will appear to persist the change. Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 11: Product Specifications

    Protection type Galvanic isolation Maximum protection voltage Maximum Network Length 500 metres (Data only) RS-232 Host Interface Transient Protection Maximum Cable Length 15 metres Auxiliary power output Voltage (DC) 12Vdc Total output current Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...
  • Page 12 SDC-650 Multiple door controller Notes: Copyright© 2015 – Saflec Systems (Pty) Ltd. http://www.saflecsystems.co.za...