Arrow 1750 D I G I T A L
OPERATING INSTRUCTIONS
., H
, NJ 07205
VE
ILLSIDE
Conforms to
UL STDs 61010-1 & 61010-2-051
Certified to
CSA STDs C22.2
No. 61010-1-12 & 61010-2-51
EN
0000000

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1750 DIGITAL and is the answer not in the manual?

Questions and answers

Summary of Contents for Arrow 1750 DIGITAL

  • Page 1 , NJ 07205 ENNSYLVANIA ILLSIDE TEL: 908-353-5233 -- FAX: 908-353-8362 EMAIL: info@arrowmixingproducts.com Website - http://www.arrowmixingproducts.com Arrow 1750 D I G I T A L OPERATING INSTRUCTIONS Conforms to UL STDs 61010-1 & 61010-2-051 Certified to CSA STDs C22.2 No. 61010-1-12 & 61010-2-51...
  • Page 2   OPERATING INSTRUCTIONS 1. Set variable speed control knob (A) to min. D (behind unit) 2. Set power switch (B) to “off” position 3. Plug in unit into outlet specified on label (E) 4. Set power switch (B) to “on position” 5.
  • Page 3 • The socket for the electric cord must be easily accessible.  stirring element.  • The electrical outlet must be grounded (protective ground  • Uncontrolled reactions can be triggered by mixing the  contact).  heated material insufficiently or by the energy generated  • The voltage stated on the label (see Fig. 1‐E) must correspond  by selecting a speed that is too high. In case of these  to the electrical outlet’s voltage.  and other increased operational hazards, users must take  • Please observe the permitted speed for the stirring element.  additional appropriate safety precautions (e.g. shatter  Never set at higher speed.  protection). In any case, when using critical or hazardous  • Make certain that the unit is set at the lowest speed before  materials in your processes, Arrow recommends using  turning the power switch on; otherwise, the unit will    additional appropriate measures to ensure safety in the  immediately begin running. Gradually increase to required  experiment. For example, users can implement measures  speed.  that inhibit fire or explosions or comprehensive monitoring  • Pay attention when setting the speed to any imbalance of  equipment. Furthermore, users must make sure that  the stirrer tools and possible spraying of the medium to  the OFF switch of the Arrow product can be accessed  be stirred.    immediately, directly and without risk at any time, and    above all, in case of fault.   Never operate the instrument with the stirrer ...
  • Page 4    Wear your personal protective  • Avoid knocking and impacting on the lower end of the equipment in accordance with  shaft and the chuck gear teeth. Even minor, invisible damage  the hazard category of the medium  can lead to imbalance and uneven shaft action.  to be processed. Otherwise there is a risk of:  • Ensure that the stand does not start to move.    • Imbalance of the output shaft, the chuck and in particular  ‐ splashing of liquids  the stirring tools can lead to uncontrolled resonant  ‐ projectile parts  vibrational behavior of the instrument and the whole  ‐ body parts, hair, clothing and jewelry getting caught.  assembly. Glass apparatus and stirrer containers can be    damaged or shattered by this. It can cause injury to the  operator, also can damage the rotating stirring tool. In   Beware of the risk of:  this case, exchange the stirring tool for one without imbalance    or remedy the cause of the imbalance. If there is  ‐ flammable materials  still imbalance, return it to the dealer or the manufacturer  ‐ glass breakage as a result of mechanical shaking power.  along with a description of the fault.    • If the instrument is operated above its capabilities, the reset   Reduce the speed if:  button will trip.    • The machine must only be opened by trained specialists,  ‐ the medium splashes out of the vessel because the  even during repair. The instrument must be unplugged  speed is too high  from the power supply before opening. Live parts inside  ‐ the instrument is not running smoothly  the instrument may still be live for some time after unplugging  ‐ the instrument begins to move around because of dynamic ...