Download Print this page

Table Of Contents - Sony CFS-W301 Service Manual

Fm/am stereo cassette-corder

Advertisement

CFS-W301
|
TABLE
OF CONTENTS
Section
Title
Page
SpecilicaHons
is 4 diecihece 2:4 OHS
Aes
He
Ewe
ers
1
Safety Check-out (US Model)
..................
2
Parts 1d@ntilication:
66-64 -d-6 Ys
BO
oa oe. eR
Eee
3
SECTION 1
ADJUSTMENTS
1-1.
Mechanical Adjustments
.................
4
1-2.
AGUSIINICN(S:
6.04.4. 45. fawkes
o-o% ee
cee
oes
6
1-3.
8
SECTION
2 DIAGRAMS
2-1.
Mounting Diagram ~ Main Section........... 11
2-2.
..........
15
2-3.
18
2-4.
.........
19
SECTION 3
EXPLODED
VIEWS
AND
PARTS
LIST
................06. 21
SECTION 4
ELECTRICAL
PARTS
LIST.........
25
SAFETY
CHECK-OUT
(US Model)
After
correcting
the
original
service
problem,
perform the following safety check before releasing
the set to the customer:
Check the antenna terminals, metal trim, "'metallized"
knobs, screws, and all other exposed metal parts for
AC leakage.
Check leakage as described below.
LEAKAGE
TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to any
exposed
metal part having a return to chassis, must
not
exceed
0.5mA
(500
microampers).
Leakage
current
can
be
measured
by
any
one
of
three
methods.
1.
A
commercial
leakage
tester,
such
as
the
Simpson
229
or RCA
WT-540A.
Follow
the
manufacturers' instructions to use these instru-
ments.
tO
A battery-operated AC milliammeter.
The Data
Precision
245
digital multimeter is suitable for
this job.
MODEL
IDENTIFICATION
- Specification Label -
US model
SON
Yo
MODEL NO. CFS-W301
"STEREO
CASSETTE-CORDER
FREQUENCY
RANGE:
FM
87.6-108MH2z
AM 530 - 1605kHz
AC: 120V 6OHz
l4W
DC: 9V FLASHLIGHT BATT
SIZE D (R20) x6 OR EQUIV
So
MADE
IN JAPAN
Canadian
model
SON
Yo
MODEL NO. CFS-W301
STEREO
CASSETTE-CORDER
FREQUENCY
RANGE:
FM
87.6-108MHz
AM 530 = 1605kH2
AC: 120V 60Hz
l4W
DC: 9V FLASHLIGHT
BATT
SIZE D (R20) x6 OR EQUIV
MADE
IN JAPAN
PA
1
LA
A
A
A
A
LR
A
A
NN
at
A
A
1
A
A
A
A
A
A
A NR RR
BR
I
I a
NR
3.
Measuring the voltage drop across a resistor by
means
of a VOM
or battery-operated
AC volt-
meter.
The
"limit"
indication
is 0.75 V, so
analog
meters
must
have
an
accurate
low-
voltage
scale.
The
Simpson
250
and
Sanwa
SH-63Trd
are examples of a passive VOM
that
is suitable.
Nearly all battery operated
digital
multimeters
that
have
a
2V
AC
range
are
suitable.
(See Fig. A)
To Exposed Metal
Parts on Set
AC
voltmeter
ea
(0.75 V)
=
Earth Ground
Fig. A.
Using an AC voltmeter to check AC leakage.