actuant Mastervolt SunMaster CS15TL RP User And Installation Manual

actuant Mastervolt SunMaster CS15TL RP User And Installation Manual

High power grid connected solar inverter
Table of Contents

Advertisement

Quick Links

SunMaster
CS15TL RP / CS20TL RP / CS30TL RP
HIGH POWER GRID CONNECTED SOLAR INVERTER
USERS AND INSTALLATION MANUAL | P01
UK |
GEBRUIKERS- EN INSTALLATIEHANDLEIDING | P45
NL |
BEDIENUNGS- UND INSTALLATIONSANLEITUNG | P93
DE |
MANUEL UTILISATEURS ET D'INSTALLATION | P141
FR |
MANUAL DEL USUARIO Y DE INSTALACIÓN | P189
ES |
MANUALE DI USO E MANUTENZIONE | P237
IT |
10000000186/04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mastervolt SunMaster CS15TL RP and is the answer not in the manual?

Questions and answers

Summary of Contents for actuant Mastervolt SunMaster CS15TL RP

  • Page 1 SunMaster CS15TL RP / CS20TL RP / CS30TL RP HIGH POWER GRID CONNECTED SOLAR INVERTER USERS AND INSTALLATION MANUAL | P01 UK | GEBRUIKERS- EN INSTALLATIEHANDLEIDING | P45 NL | BEDIENUNGS- UND INSTALLATIONSANLEITUNG | P93 DE | MANUEL UTILISATEURS ET D’INSTALLATION | P141 FR | MANUAL DEL USUARIO Y DE INSTALACIÓN | P189 ES |...
  • Page 2 02 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP...
  • Page 3 | 03 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP OVERVIEW CS15TL RP/ CS20TL RP/ CS30TL RP Figure 0-1: Overview of the SunMaster CS15TL RP / CS20TL RP / CS30TL RP 1. 3-phase 400V grid connection 6. Solar input 1 2.
  • Page 4: Table Of Contents

    04 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP CONTENT 10000000186/04 March 2013 GENERAL INFORMATION PRODUCT DESCRIPTION USE OF THIS MANUAL VALIDITY OF THIS MANUAL SCOPE OF GUARANTEE LIABILITY CHANGES TO THE INVERTER IDENTIFICATION LABEL SAFETY GUIDELINES AND WARNINGS WARNINGS AND SYMBOLS USE FOR INTENDED PURPOSE INSTALLATION, MAINTENANCE, REPAIR...
  • Page 5 | 05 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP DISPLAY BUTTONS THE HOME SCREEN MAIN MENU ENERGY TOTALS PLANT TOTALS MULTIMETER & STRINGMASTER DATALOGGER LOGBOOK CONFIGURATION MENU SPECIFIC DC CONFIGURATIONS ISOLATION DETECTION USING A STRINGMASTER PRO DC SWITCH SPECIFIC AC CONFIGURATIONS 10.1...
  • Page 6: General Information

    06 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 1 GENERAL INFORMATION 1.1 PRODUCT DESCRIPTION 1.5 LIABILITY The SunMaster CS15TL, CS20TL and CS30TL, further Mastervolt accepts no liability for: referred to as “SunMaster CS” or “CS inverter” are grid •...
  • Page 7: Safety Guidelines And Warnings

    | 07 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP SAFETY GUIDELINES AND WARNINGS WARNINGS AND SYMBOLS INSTALLATION, MAINTENANCE, REPAIR Safety instructions and warnings are marked in this manual by the following pictograms: WARNING As dangerous voltages exist, only allow A procedure, circumstance, etc which installation, maintenance and repair of the deserves extra attention.
  • Page 8: How It Works

    08 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP HOW IT WORKS The CS inverter is a grid connected photovoltaic power inverter. It converts the high voltage DC power coming from the photovoltaïc (PV) panels into AC power. The AC voltage is fed back into the public utility grid.
  • Page 9: Display And Monitoring

    | 09 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP DISPLAY AND MONITORING REACTIVE POWER As per January 1st 2012, PV installations in Germany 3.5.1 CS inverter display capable of generating more than 3,68 kVA will be required to The CS inverter is equipped with a multi language display for on site monitoring and control.
  • Page 10: Before You Start

    10 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP BEFORE YOU START Air outlet Air outlet Air outlet TRANSPORT, LIFTING AND STORAGE Ensure adequate and secure packaging during transportation of the CS inverter. Always use suitable handling equipment for transportation. More than two persons may be required to hang the CS inverter to a wall, refer to local safety standards.
  • Page 11: Solar Array Capacitance

    | 11 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 4.3.1 Recommended cabling All devices within the PV installation (panels, wiring, terminal blocks, fuse holders, fuses, switches, etc.) must be rated for the applicable maximum voltage and current ratings. Use double isolated DC cabling for all connections.
  • Page 12: Ac Output Specifications

    12 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP The SunMaster CS is designed to operate with a solar ar- AC wiring ray capacitance up to 6 µF. Larger array capacitances may Model CS15TL RP CS20TL RP CS30TL RP cause too large leakage currents, and can trip the internal Minimum cable RCD protection.
  • Page 13: General Installation And Commissioning

    | 13 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP GENERAL INSTALLATION AND COMMISSIONING • 2 MasterBus terminating devices (included) This chapter describes the general installation of one single inverter. For example, specific installations with more than •...
  • Page 14: Mounting The Inverter

    14 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP See figure 5-5. MOUNTING THE INVERTER Fix the CS inverter to the wall, starting with the mounting AC connector: refer to section 5.4, bracket. See figure 5-3. Use suitable screws and plugs. Communication module: refer to chapter 7, PV input: refer to section 4.3.
  • Page 15: Connecting And Commissioning

    | 15 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP CONNECTING AND COMMISSIONING To check the correct operation of the CS inverter, commissioning should be carried out during daytime only. Follow these steps to switch On the SunMaster CS: 1 Connect the earth cable to the ground stud.
  • Page 16: Operation And Maintenance

    16 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP OPERATION AND MAINTENANCE This chapter describes the operation of one single inverter. 6.2.3 Air outlet The CS inverter is provided with wire mesh behind the air outlets (fig. 6-2). GENERAL After installation and commissioning the CS inverter will switch on automatically if solar irradiation is sufficient.
  • Page 17: Communication

    | 17 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP COMMUNICATION COMMUNICATION MODULE CAUTION: The CS inverter is equipped with a detachable communication Never connect a non-MasterBus device to the module (drawer) for inserting the MasterBus and RS485 plugs. MasterBus network directly! This will void It also facilitates mounting the alarm wiring.
  • Page 18: Rs485 Connectors

    18 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP Figure 7-4 RS485 CONNECTORS The two connectors in the centre of the connection blockare RS485 connectors. They can be used for connecting up to 20 CS inverters. They also connect your inverter to an optional Datalogger.
  • Page 19: Display

    | 19 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP DISPLAY The SunMaster CS is fitted with a multi-lingual graphic d. Today’s power generation display allowing to view operational data and access all e. Inverter status, error messages and warnings setting parameters.
  • Page 20: Plant Totals

    20 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP Figure 8-4: Energy totals Figure 8-6: Plant Totals screens 2 The BACK button has the display return to the Main Menu. 8.5.2 Plant Totals – Inverter Information The performance of each inverter in the plant is further detailed in the Inverter Info screens.
  • Page 21: Multimeter & Stringmaster

    | 21 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP a. Inverter Number. This number relates to the power bar d. PV power shown in the PT Overview screen. The rated PV panel capacity installed on this particular b.
  • Page 22: Datalogger

    22 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP • Day-to-day energy shows a 10-minute accurate profile of Before showing accurate information, the StringMaster measurements must be configured in the StringMaster the energy generated for the past 30 days. •...
  • Page 23: Logbook

    | 23 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP • Best hour/day/month. For example, how much energy The Main Menu shows 8 icons as presented in figure 8-16. was generated at the best hour of the shown day. Select one of the icons using the Navigation buttons and •...
  • Page 24 24 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP Insulation a. Function. Describes how the insulation detection should respond to a fault. There are several options: On For normal installations. Inverter will shut down in case of insulation failure.
  • Page 25 | 25 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP a. Sleep Mode. Sleep mode switches off the backlight, and 8.9.2.4 DNO Power Control For some PV installations, the local grid operator (Distribu- returns the display to the Home Screen, when no buttons tion Network Operator, DNO) may require the possibility to are pressed for more than 5 minutes reduce the power output of the PV plant by remote com-...
  • Page 26 26 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP The following settings are available: Pressing Continue confirms to reset the inverter to the factory settings. Alarm Contact Settings Alarm On, Off Select Event On, Insulation Error, The installer password must be entered before Solar OK, Grid Fault, Error the inverter can be reset to factory defaults.
  • Page 27 | 27 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 8.9.9 Automatic String Performance Monitoring Together with the StringMaster Pro, the CS inverter can autonomously monitor the performance of each string and compare it to the rest of the plant. If one string underperforms (for example, because of dust deposits or connector failures) compared to the others in that input, the inverter will issue a warning on the home screen and...
  • Page 28: Specific Dc Configurations

    28 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP SPECIFIC DC CONFIGURATIONS This chapter describes specific features of special USING A STRINGMASTER PRO installations and options using the CS inverter. It was 9.2.1 DC Distribution written to be an addition to chapter 5 General Installation The CS inverter has two independent solar inputs.
  • Page 29: Specific Ac Configurations

    | 29 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 10 SPECIFIC AC CONFIGURATIONS This chapter describes specific features of special installations and options using the CS inverter. It was written to be an addition to chapter 5 General Installation and Commissioning. 10.1 SUPPORTED COUNTRIES In the next table, the selectable country codes are displayed.
  • Page 30 30 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP Uo Max-TEST (Uac Min-TEST) Figure 10-1 shows: Measured value: = the actual grid voltage; Setting: the set maximum / minimum inverter voltage limit Max. Trip time Maximum time for inverter to shut down after tripping During this test the high (low) voltage limit is changed with Rate -11.5V/sec (+11.5V/sec) until it trips: it reaches the...
  • Page 31: Active Power Management

    | 31 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 10.3 ACTIVE POWER MANAGEMENT This section describes all types of power management available on the SunMaster CS inverter. 10.3.1 Power management by Telecontrol For some PV installations, the local grid operator (Distribution Network Operator, DNO) may require the possibility to reduce the power output of the PV plant by remote commands.
  • Page 32: Reactive Power Explanation

    32 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP will increase its output power after the frequency has The inverter can be set up to reduce the reactive power in recovered, or after a grid fault has been cleared. four different ways: 4 independent setpoints are available: 1.
  • Page 33: Using An Isolation Transformer

    | 33 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 10.5.2 Voltage dependent Q control This control law (Q – U control) produces an amount of reactive power based on the actual grid voltage. Figure 10-9 Capacitive Upper shows an example demonstrating the available parameters.
  • Page 34 34 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 10.6.2 PV array earthing If the PV array is not grounded and local regulations require this, it is allowed to ground the neutral at the transformer side (TN network) If the PV array is functionally earthed it is recommended to use a separate transformer for each inverter, or to use a transformer with multiple isolated windings.
  • Page 35: Functional Grounding

    | 35 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 11 FUNCTIONAL GROUNDING 11.1 FUNCTIONAL GROUNDING During normal operation, the CS inverter will balance the DC voltage on its terminals around the PE potential. This means the negative DC terminal will operate on a negative poten- tial with respect to PE and vice versa for the positive DC terminal.
  • Page 36: Trouble Shooting

    36 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 12 TROUBLE SHOOTING 12.1 LED INDICATION AND SOLUTION TABLE Fast blink= 2 blinks per second, slow blink = 1 blink per second LED indication Display indication Description What to do No LED function No display function...
  • Page 37: Technical Specifications

    | 37 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 13 TECHNICAL SPECIFICATIONS CS15TL RP CS20TL RP CS30TL RP GENERAL SPECIFICATIONS Operating temp. Ambient temperature -20°C to 60°C (full power up to 45 °C. ) Enclosure Powder coated aluminum Protection degree IP65 electronics for outdoor application Pollution degree...
  • Page 38: Outline Drawings

    38 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP SYSTEM INFORMATION User interface Multi-language black-on-white graphical LCD display. Languages: English, Nederlands, Deutsch, Français, Castellano, Italiano Diagnostics • 10 years datalogger and real time clock • 10 years diagnostic memory External communication A: MasterBus stringbox and transformer interface with two connectors B: MasterBus field service interface with two connectors...
  • Page 39: Ordering Information

    | 39 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 14 ORDERING INFORMATION Part number Description 131210150 SunMaster CS15TL RP with Reactive Power 131210200 SunMaster CS20TL RP with Reactive Power 131210300 SunMaster CS30TL RP with Reactive Power 131300500 SwitchMaster CS 2-3 SW 30 string box for maximum 2x3 strings.
  • Page 40: Certificates

    40 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 15 CERTIFICATES 15.1 VDE AR N 4105 CERTIFICATE OF COMPLIANCE...
  • Page 41: Rd 1699 Compliance

    | 41 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 15.2 RD 1699 COMPLIANCE...
  • Page 42: Enel Certificate

    42 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 15.3 ENEL CERTIFICATE...
  • Page 43: Bdew Certificate

    | 43 EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 15.4 BDEWLINK_15.4.PNG...
  • Page 44: Ec Declaration Of Conformity

    44 | EN / SunMaster CS15TL RP / CS20TL RP / CS30TL RP 15.5 EC DECLARATION OF CONFORMITY The undersigned, Mastervolt International B.V. Snijdersbergweg 93, 1105AN P.O box 22947 1100DK Amsterdam 2011 The Netherlands Tel: +31-(0)20-3422100 Fax: +31-(0)20-6971006 being the manufacturer, declares under his sole responsibility that the electronic equipment: Product group: Solar Inverter Brand: MASTERVOLT...

Table of Contents