Reproduction of any part of this manual, in any form, without the express written permission of DAV Tech. The text and illustrations in this manual are not binding, the DAV tech reserves the right, at any time and without notice, the right to make any changes to improve the product or for reasons of character manufacturing or commercial.
Installation and maintenance guide 3 SAFETY PRECAUTION THE SAFETY PRECAUTIONS HAVE BEEN CLASSIFIED INTO “DANGER” AND “CAUTION”. “DANGER” means that dangerous situations can occur and death or serious injury could result, if handled incorrectly. “CAUTION” means that dangerous situations can occur if handled incorrectly. Also you may get serious injury or physical damage.
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM Precautions on Installation 1. Do not install, store and use in places exposed to conductive dust, corrosive gas, flammable gas, high temperature, condensa- tion, wind and rain, etc. 2. Exposure to direct sunlight for a long time will degrade accuracy of the equipment. Do not install, store, or use in areas where there is direct sunlight.
Page 6
4 DA 1000V 4 .1 Features DAV 1000 V is a compact dispenser that enables ultra-quantitative dispense regardless of changes in the internal differential head and viscosity of the barrel by adopting a precision linear actuator and a step motor.
Page 7
This equipment is applied by using dispenser, and it can be applied to the robot to determine and adjust the application method. One-component dispensing Nano Pen Controller (NPC-10) is ideal for spot application and DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM precise and versatile operation is possible. Data recognition with color touch screen is easy to operate.
Page 8
This picture above shows the basic components of the DA 1000V Controller, and their descriptions are as follows. Picture Name Description DAV 1000V Controller This is the DAV 1000V controller. This is the cable that connects the DAV DAV 1000V Cable 1000V to the Controller. DAV 1000V This is the DAV 1000V...
Page 10
Installation and maintenance guide 6.2 DA 1000V CONTROLLER Name and Function of Each Component NANO PENNANOPEN Operation Manual Doc. Rev 0 5.2 NPC-10 Name and Function of Each Component NANO PENNANOPEN Operation Manual Doc. Rev 0 NANO PENNANOPEN Operation Manual Doc.
Page 11
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM Name and Display Function and Description NANO PENNANOPEN Operation Manual Doc. Rev 0 <Frame Ground> <Frame Ground> This is the grounding connector for the power for the NANO PENNANOPEN Operation Manual Doc. Rev 0 This is the grounding connector for the power for DA 1000V Controller.
Page 12
BUSY: Indicates the status when contro is in progress. OUTPUT Socket Installation and maintenance guide END: Indicates the end of a control op RDY: Indicates the status when contro is enabled. ERR: This signal is indicated when Name and Display Function and Description <OUTPUT Socket>...
Page 13
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM NANO PENNANOPEN Operation Manual Doc. Rev 0 6.3 Basic Instructions for Operating the HMI Screen NANO PENNANOPEN Operation Manual Doc. Rev 0 5.3 Basic Instructions for Operating the HMI Screen 6.3.1 Switching Pages 5.3 Basic Instructions for Operating the HMI Screen 5.3.1 Switching Pages...
Installation and maintenance guide NANO PENNANOPEN Operation Manual NANO PENNANOPEN Operation Manual Doc. Rev 0 Doc. Rev 0 6.3.2 Changing Settings 5.3.2 5.3.2 Changing Settings Changing Settings Figure 5. Example of changing setting value Figure 5. Example of changing setting value Figure 5.
Page 15
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM 6.4 5.4 Explanation of HMI Screen Structure NANO PENNANOPEN Operation Manual Doc. Rev 0 Explanation of HMI Screen Structure Figure 7. NPC-10 HMI Screen Structure Figure 7. DA 1000V Controller HMI Screen Structure Figure 7 shows the NPC-10 HMI Screen Structure.
Page 16
NANO PENNANOPEN Operation Manual NANO PENNANOPEN Operation Manual Installation and maintenance guide NANO PENNANOPEN Operation Manual NANO PENNANOPEN Operation Manual 5.4.1 Brief Description of PAGE ICON 5.4.1 Brief Description of PAGE ICON 5.4.1 Brief Description of PAGE ICON 6.4.1 Brief Description of PAGE ICON 5.4.1 Brief Description of PAGE ICON PAGE PAGE...
Page 17
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM NANO PENNANOPEN Operation Manual Doc. Rev 0 7 OPERATION OF THE EQUIPMENT Operation of the Equipment 7.1 Initial Power Input 6.1 Initial Power Input Figure 8. Initial power input screen Figure 8. Initial power input screen...
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM 7.3.3 Mounting DA 1000V Barrel Figure 13. DA 1000V Mounting Order As shown in Figure 13, mount the Barrel and Barrel Holder (with Plunger and liquid) onto the DA 1000V. 7.3.4 Fastening the Plunger Figure 14. Locking the Plunger using the SHOT button After setting the DA 1000V’s direction to FORWARD, pressing the SHOT button will be that load...
Page 21
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM NANO PENNANOPEN Operation Manual Doc. Rev 0 7.5 How to Remove the BARREL 6.5 How to Remove the BARREL TOUCH Figure 17. Using AUTO BACK function Figure 17. Using AUTO BACK function Figure 18. Use the SHOT SWITCH or the FOOT SWITCH As shown in Figure 17, the Plunger and Barrel can be removed by using the AUTO BACK function, or by using the SHOT or FOOT Switch after configuring the setting to BACKWARD.
NANO PENNANOPEN Operation Manual Doc. Rev 0 7.1 HOME PAGE Installation and maintenance guide Explanation of HMI Screen PAGE NANO PENNANOPEN Operation Manual NANO PENNANOPEN Operation Manual Doc. Rev 0 Doc. Rev 0 NANO PENNANOPEN Operation Manual Doc. Rev 0 8 EXPLANATION OF HMI SCREEN PAGE 7.1 HOME PAGE TIME...
Page 23
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM 8.1.1 TIME MODE NANO PENNANOPEN Operation Manual Doc. Rev 0 Time Mode is a Dispensing Mode that dispenses a set volume over a set duration. Time Mode is a Dispensing Mode that dispenses a set volume over a set duration.
Page 24
Installation and maintenance guide NANO PENNANOPEN Operation Manual Doc. Rev 0 8.1.2 STEADY MODE 7.1.2 STEADY MODE Steady Mode is a Dispensing Mode where discharge is continuously executed at a set SPEED, and it is mainly used for Line Dispensing a certain amount. Steady Mode is a Dispensing Mode where discharge is continuously executed at a set SPEED, and it is mainly used for Line Dispensing a certain amount.
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM 8.1.3 INTERVAL MODE NANO PENNANOPEN Operation Manual Doc. Rev 0 Interval Mode is a Dispensing Mode used to consecutively dispense in Time Mode. 7.1.3 INTERVAL MODE When selected, the equipment alternates between Dispensing ON/OFF, and during the ON signal, material will be dispen- Interval Mode is a Dispensing Mode used to consecutively dispense in Time Mode.
Page 26
Installation and maintenance guide 8.1.4 SEQUENCE MODE Sequence Mode is a Dispensing Mode where up to 16 desired condition values can be configured, and each PROGRAM NANO PENNANOPEN Operation Manual Doc. Rev 0 sequentially dispenses the material according to the various conditions. Sequence Mode is a Dispensing Mode where up to 16 desired condition values can be configured, and each PROGRAM sequentially dispenses the material according to the various conditions.
Page 28
Installation and maintenance guide CATEGORY DESCRIPTION NANO PENNANOPEN Operation Manual Doc. Rev 0 → If the SPEED text box is touched, the setting will switch to NANO PENNANOPEN Operation Manual Doc. Rev 0 NANO PENNANOPEN Operation Manual Doc. Rev 0 STEP.
Page 29
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM NANO PENNANOPEN Operation Manual Doc. Rev 0 7.3 MENU PAGE 8.3 MENU PAGE Figure 25. MENU PAGE Figure 25. MENU PAGE Category Description DESCRIPTION CATEGORY SETTING Go to SETTING Screen ALARM Go to ALARM Screen...
Page 34
Installation and maintenance guide NANO PENNANOPEN Operation Manual Doc. Rev 0 8.5 BARREL SETTING PAGE Figure 30. Setting : Barrel PAGE Figure 30. Setting : Barrel PAGE The INTERVAL MODE SETTING PAGE is the PAGE to configure the repeated dispensing conditions. This is the PAGE to configure the Barrel capacity according to the Nano Pen capacity.
Installation and maintenance guide NANO PENNANOPEN Operation Manual Doc. Rev 0 8.8 ALARM PAGE 7.8 ALARM PAGE Figure 33. ALARM PAGE Figure 33. ALARM PAGE Category Description If the external INPUT EMERGENCY signal is ON, all EMERGENCY DESCRIPTION CATEGORY operations of the NPC-10 will stop. If the external INPUT EMERGENCY signal is ON, all operations of the EMERGENCY OVER-CURRENT...
Page 37
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM NANO PENNANOPEN Operation Manual Doc. Rev 0 8.9 TEST PAGE 7.9 TEST PAGE Figure 34. I/O TEST PAGE Figure 34. I/O TEST PAGE Category Description SHOT SW NPC-10 front panel switch contact point test CATEGORY DESCRIPTION EXT.DI - FOOT...
Page 38
Installation and maintenance guide NANO PENNANOPEN Operation Manual Doc. Rev 0 8.10 INFO PAGE 7.10 INFO PAGE NO PENNANOPEN Operation Manual Doc. Rev 0 7.10 INFO PAGE NANO PENNANOPEN Operation Manual Doc. Rev 0 7.10 INFO PAGE Figure 35. INFO PAGE Figure 35.
Page 39
DA1000V VOLUMETRIC MANUAL DISPENSING SYSTEM 8.10.1 Barrel Information PAGE NANO PENNANOPEN Operation Manual Doc. Rev 0 Figure 36. Barrel Information PAGE Figure 36. Barrel Information PAGE This is the information regarding the dispensing volume for each Barrel capacity. Touching the This is the information regarding the dispensing volume for each Barrel capacity.
Page 40
DAV TECH SRL Via Ravizza, 30 - 36075 Montecchio Maggiore (VI) - ITALY - Tel. 0039 0444 574510 - Fax 0039 0444 574324 davtech@davtech.it - www.davtech.it We reserve the right to modify at any time, without notice, the specifications, dimensions and weights in this manual. The illustrations are not binding.