The varmo TZ pro is an electronic radiator thermostat, intended for use with water based room radiators. The varmo TZ pro valve is supplied with adapters for RA valves and valves with M30 x 1.5 (K) connections, two alkaline AA batteries and a 2 mm Allen key.
Remove the battery cover and insert two AA batteries. Make sure the batteries are correctly oriented.
Rechargeable batteries must not be used.
If the battery goes flat, the system switches automatically to safety mode where the valve is slightly opened providing a small continuous water flow.
M must be flashing on the display prior to installing.
| ||
| ||
| ||
|
Use to navigate the display and the menus and to set the temperature, and use to select and confirm.
The temperature is usually controlled via the DONEXON App, but may be changed at any time using the varmo TZ pro buttons. If this is done, the varmo TZ pro sends a message to the Z-Wave controller which then syncronises other varmo TZ pro in the same room.
Press to change the temperature.
The DONEXON App can instruct the varmo TZ pro to enter Fully Closed (FC) or Fully Open (FO) modes. When in either of these modes, the buttons can not be used to leave the mode nor change the temperature.
If the varmo TZ pro has been removed from the radiator and needs to be reinstalled (after being used), it is necessary to activate installation mode to prevent damage to the varmo TZ pro.
To enter installation mode:
If the varmo TZ pro is moved to another room, make sure to make the necessary changes in the DONEXON App.
Thermostat type | Programmable electronic radiator valve controller |
Recommended use | Residential (pollution degree 2) |
Actuator | Electro-mechanical |
Display | Grey with back-light |
Software classification | A |
Control | PID |
Transmission frequency | 868.42 MHz |
Transmission range | up to 30 m |
Power supply | 2 x 1.5V AA alkaline, class III |
Power consumption | 3 µW in standby, 1.2 W when active |
Battery life | 2 years |
Low battery signal | Battery icon will flash in display. If battery level is critical, the display will flash. |
Ambient temperature | 0 to 40°C |
Transportation temperature. | -20 to 65°C |
Max. water temperature | 90°C |
Temperature setting range | 4 to 28°C |
Measurement interval | Measures temperature every min. |
Clock accuracy | +/- 10 min./year |
Spindle movement | Linear, up to 4.5 mm, max. 2 mm on valve (1 mm/s) |
Noise level | <30 dBA |
Safety classification | Type 1 |
Weight | 177 g incl. RA adapter |
IP class* | 20 |
The varmo TZ pro can be controlled by a Z-Wave certified controller, which supports the appropriate command classes.
Press for at least 3 seconds until M is displayed.
Press until is displayed.
Press to test the connection.
disappears when the connection is made.
If no connection can be made, the alarm symbol and the antenna symbol flashes.
Remove the battery cover and take out one battery. Press and hold for approx. 5 seconds, while reinserting the battery. The varmo TZ pro is now factory reset and in mounting mode.
A controller can only communicate with the varmo TZ pro, when the device is awake. The intervals when the varmo TZ pro is awake can be set using the "wake up command class". Press to manually wake up the device. It will stay awake for 10 seconds and send out a node info.
Z-Wave Device Classes | Device Class Implemented |
Generic device | GENERIC_TYPE_THERMOSTAT |
Specific device | SPECIFIC_TYPE_SETPOINT_THERMOSTAT |
Device type | Slave |
SDK | 4.55 |
Software version | 1.00 |
Manufacturer ID | 0x0002 |
Product Type | 0x5FFF |
Product ID | 0xA010 |
Explorer frames | YES |
Z-Wave Command Classes Supported | Description |
COMMAND_CLASS_BATTERY | Get current battery status of the varmo TZ pro. |
COMMAND_CLASS_CLI-MATE_CONTROL_SCHEDULE | Control a temperature offset to the thermostat setpoint of the varmo TZ pro. The temperature offset is defined by schedules and schedule overrides. |
COMMAND_CLASS_CLOCK | Set or get the current clock on the varmo TZ pro. |
COMMAND_CLASS_MANUFACTURER_SPECIFIC | Get manufacturer ID of system. |
COMMAND_CLASS_MULTI_CMD | A special Z-Wave command used by the varmo TZ pro to encapsulate multiple commands in one command and thereby conserve battery life. |
COMMAND_CLASS_PROTECTION | Set or get the varmo TZ pro local protection mode. Possible local protection values are: 0 = no protection 2 = fully locked (tamperproof) |
COMMAND_CLASS_THERMOSTAT_SETPOINT | Set or get current thermostat setpoint. The varmo TZ pro regulates the room temperature to setpoint values in the range from 4°C to 28°C. Special setpoint values: <4°C: Fully Closed valve >28°C: Fully Open valve |
COMMAND_CLASS_VERSION | Get version of product and command classes. |
COMMAND_CLASS_ WAKE_UP | A special Z-Wave command used by the varmo TZ pro to synchronize communication with its controller. |
COMMAND_CLASS_SENSOR_MULTILEVEL | Get temperatures: Sensor Type 0x01: Corrected measured room temperature Sensor Type 0x17: Water temperature indication |
Error code | Action |
E1, E2, E3, E4 | Contact DONEXON Support. |
E5 | The varmo TZ pro is not receiving the expected replies from the Z-Wave controller. Remove the batteries for 10 seconds and replace to clear the E5 error. |
Tested for safety and EMC requirements as specified in EN 60730-1, EN 60730-2-9, EN 60730-2-14, EN 300 220-2, EN 301 489-, EN 301 489-3 and RED directive.
www.donexon.com/support
The thermostat is not intended for children and must not be used as a toy. Do not leave packaging materials where children may be tempted to play with them, as this is extremely dangerous. Do not attempt to dismantle the varmo TZ pro smart radiator valve as it contains no userserviceable parts. If error code E1, E2, E3 or E4 is shown in the display or other defects appear, please return the varmo TZ pro valve to VARIA3 GmbH.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download DONEXON varmo TZ pro - Thermostat Installation Guide
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the varmo TZ pro that isn't answered in the manual? Leave your question here.