The varmo TZ pro is an electronic radiator thermostat, intended for use with water based room radiators. The varmo TZ pro valve is supplied with adapters for RA valves and valves with M30 x 1.5 (K) connections, two alkaline AA batteries and a 2 mm Allen key.

Inserting the batteries


Remove the battery cover and insert two AA batteries. Make sure the batteries are correctly oriented.
Rechargeable batteries must not be used.
If the battery goes flat, the system switches automatically to safety mode where the valve is slightly opened providing a small continuous water flow.

Installing the varmo TZ pro

M must be flashing on the display prior to installing.

  1. Start by mounting the appropriate adapter.
  1. Tighten RA adapter using the Allen key, hand-tighten the K adapter (max. 5 Nm).
  1. Screw the varmo TZ pro valve onto the adapter and tighten by hand (max. 5 Nm).
  1. Press for approx. 3 seconds to fix the varmo TZ pro smart radiator valve and leave mounting mode.

Including the device onto a Z-Wave controller

  • Ensure the varmo TZ pro is factory reset.
  • Follow the wizard on the app for adding a device to the system.
  • When instructed to, by the app, quickly press and release the on the varmo TZ pro.
  • Observe the app for the status of the process.

Display and buttons

Display and buttons
Use to navigate the display and the menus and to set the temperature, and use to select and confirm.

Temperature control and adjustment

The temperature is usually controlled via the DONEXON App, but may be changed at any time using the varmo TZ pro buttons. If this is done, the varmo TZ pro sends a message to the Z-Wave controller which then syncronises other varmo TZ pro in the same room.

Press to change the temperature.
The DONEXON App can instruct the varmo TZ pro to enter Fully Closed (FC) or Fully Open (FO) modes. When in either of these modes, the buttons can not be used to leave the mode nor change the temperature.
Temperature control and adjustment

Re-installation mode

If the varmo TZ pro has been removed from the radiator and needs to be reinstalled (after being used), it is necessary to activate installation mode to prevent damage to the varmo TZ pro.

To enter installation mode:

  • Press until is displayed.
  • Press again to withdraw the spindle. flashes.
  • Reinstall the varmo TZ pro on the valve.
  • Press for approx. 3 seconds to fix the varmo TZ pro.

If the varmo TZ pro is moved to another room, make sure to make the necessary changes in the DONEXON App.

Technical information

  • If the varmo TZ pro does not get correct and timely replies (e.g. if the Z-Wave controller is turned off) it will automatically switch to 30 minutes wake up intervals and display an E5 error on the screen. If at next wake up the Z-Wave controller replies as expected, the varmo TZ pro will switch back to the original wake up interval.
  • The varmo TZ pro will not commence its periodic communications if it is in "Mounting mode". "Mounting mode" is for physical installation. Please see section "Installing the varmo TZ pro" for instructions on how to leave "Mounting mode".

Technical specifications

Thermostat type Programmable electronic radiator valve controller
Recommended use Residential (pollution degree 2)
Actuator Electro-mechanical
Display Grey with back-light
Software classification A
Control PID
Transmission frequency 868.42 MHz
Transmission range up to 30 m
Power supply 2 x 1.5V AA alkaline, class III
Power consumption 3 µW in standby,
1.2 W when active
Battery life 2 years
Low battery signal Battery icon will flash in display. If battery level is critical, the display will flash.
Ambient temperature 0 to 40°C
Transportation temperature. -20 to 65°C
Max. water temperature 90°C
Temperature setting range 4 to 28°C
Measurement interval Measures temperature every min.
Clock accuracy +/- 10 min./year
Spindle movement Linear, up to 4.5 mm, max. 2 mm on valve (1 mm/s)
Noise level <30 dBA
Safety classification Type 1
Weight 177 g incl. RA adapter
IP class* 20

Z-Wave Information

The varmo TZ pro can be controlled by a Z-Wave certified controller, which supports the appropriate command classes.
Z-Wave Information

Including the device to a network

  • Ensure the varmo TZ pro is factory reset.
  • Activate "Inclusion" on the Z-Wave controller.
  • Quickly press and release on the varmo TZ pro.
  • Observe both controller and varmo TZ pro for status of the process.

Testing the connection


Press for at least 3 seconds until M is displayed.


Press until is displayed.

Press to test the connection.

disappears when the connection is made.

If no connection can be made, the alarm symbol and the antenna symbol flashes.

Excluding the device from the network

  • Activate "Exclusion" on the Z-Wave controller.
  • Quickly press and release on the varmo TZ pro.
  • Observe both controller and the varmo TZ pro for status of the process.

Factory reset

Remove the battery cover and take out one battery. Press and hold for approx. 5 seconds, while reinserting the battery. The varmo TZ pro is now factory reset and in mounting mode.

Wake up

A controller can only communicate with the varmo TZ pro, when the device is awake. The intervals when the varmo TZ pro is awake can be set using the "wake up command class". Press to manually wake up the device. It will stay awake for 10 seconds and send out a node info.

Implemented Z-Wave device classes

Z-Wave Device Classes Device Class Implemented
Generic device GENERIC_TYPE_THERMOSTAT
Specific device SPECIFIC_TYPE_SETPOINT_THERMOSTAT

Z-wave info

Device type Slave
SDK 4.55
Software version 1.00
Manufacturer ID 0x0002
Product Type 0x5FFF
Product ID 0xA010
Explorer frames YES

Supported and controlled Z-Wave command classes

Z-Wave Command Classes Supported Description
COMMAND_CLASS_BATTERY Get current battery status of the varmo TZ pro.
COMMAND_CLASS_CLI-MATE_CONTROL_SCHEDULE Control a temperature offset to the thermostat setpoint of the varmo TZ pro. The temperature offset is defined by schedules and schedule overrides.
COMMAND_CLASS_CLOCK Set or get the current clock on the varmo TZ pro.
COMMAND_CLASS_MANUFACTURER_SPECIFIC Get manufacturer ID of system.
COMMAND_CLASS_MULTI_CMD A special Z-Wave command used by the varmo TZ pro to encapsulate multiple commands in one command and thereby conserve battery life.
COMMAND_CLASS_PROTECTION Set or get the varmo TZ pro local protection mode. Possible local protection values are:
0 = no protection
2 = fully locked (tamperproof)
COMMAND_CLASS_THERMOSTAT_SETPOINT Set or get current thermostat setpoint.
The varmo TZ pro regulates the room temperature to setpoint values in the range from 4°C to 28°C.
Special setpoint values:
<4°C: Fully Closed valve >28°C: Fully Open valve
COMMAND_CLASS_VERSION Get version of product and command classes.
COMMAND_CLASS_ WAKE_UP A special Z-Wave command used by the varmo TZ pro to synchronize communication with its controller.
COMMAND_CLASS_SENSOR_MULTILEVEL Get temperatures:
Sensor Type 0x01: Corrected measured room temperature Sensor Type 0x17: Water temperature indication

Troubleshooting

Error code Action
E1, E2, E3, E4 Contact DONEXON Support.
E5 The varmo TZ pro is not receiving the expected replies from the Z-Wave controller. Remove the batteries for 10 seconds and replace to clear the E5 error.

Safety precautions

Tested for safety and EMC requirements as specified in EN 60730-1, EN 60730-2-9, EN 60730-2-14, EN 300 220-2, EN 301 489-, EN 301 489-3 and RED directive.
www.donexon.com/support
The thermostat is not intended for children and must not be used as a toy. Do not leave packaging materials where children may be tempted to play with them, as this is extremely dangerous. Do not attempt to dismantle the varmo TZ pro smart radiator valve as it contains no userserviceable parts. If error code E1, E2, E3 or E4 is shown in the display or other defects appear, please return the varmo TZ pro valve to VARIA3 GmbH.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download DONEXON varmo TZ pro - Thermostat Installation Guide

Advertisement

Need Assistance?

Do you have a question about the varmo TZ pro that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents